130 research outputs found

    Spectral properties of finite laser-driven lattices of ultracold Rydberg atoms

    Full text link
    We investigate the spectral properties of a finite laser-driven lattice of ultracold Rydberg atoms exploiting the dipole blockade effect in the frozen Rydberg gas regime. Uniform one-dimensional lattices as well as lattices with variable spacings are considered. In the case of a weak laser coupling, we find a multitude of many-body Rydberg states with well-defined excitation properties which are adiabatically accessible starting from the ground state. A comprehensive analysis of the degeneracies of the spectrum as well as of the single and pair excitations numbers of the eigenstates is performed. In the strong laser regime, analytical solutions for the pseudo-fermionic eigenmodes are derived. Perturbative energy corrections for this approximative approach are provided.Comment: 17 pages, 12 figure

    Rydberg-atom trajectories in a ponderomotive optical lattice

    Full text link
    Using semiclassical simulations, we investigate the trajectories and the microwave spectra of Rydberg atoms excited in a ponderomotive optical lattice. We relate distinct features found in the microwave spectra to characteristic types of trajectory. Several methods are presented that are designed to greatly improve the trapping efficiency of the lattice and to generalize the trapping from one to three dimensions.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85435/1/njp10_11_113036.pd

    The impact of a high‐definition multileaf collimator for spine SBRT

    Full text link
    PurposeAdvanced radiotherapy delivery systems designed for high‐dose, high‐precision treatments often come equipped with high‐definition multi‐leaf collimators (HD‐MLC) aimed at more finely shaping radiation dose to the target. In this work, we study the effect of a high definition MLC on spine stereotactic body radiation therapy (SBRT) treatment plan quality and plan deliverability.Methods and MaterialsSeventeen spine SBRT cases were planned with VMAT using a standard definition MLC (M120), HD‐MLC, and HD‐MLC with an added objective to reduce monitor units (MU). M120 plans were converted into plans deliverable on an HD‐MLC using in‐house software. Plan quality and plan deliverability as measured by portal dosimetry were compared among the three types of plans.ResultsOnly minor differences were noted in plan quality between the M120 and HD‐MLC plans. Plans generated with the HD‐MLC tended to have better spinal cord sparing (3% reduction in maximum cord dose). HD‐MLC plans on average had 12% more MU and 55% greater modulation complexity as defined by an in‐house metric. HD‐MLC plans also had significantly degraded deliverability. Of the VMAT arcs measured, 94% had lower gamma passing metrics when using the HD‐MLC.ConclusionModest improvements in plan quality were noted when switching from M120 to HD‐MLC at the expense of significantly less accurate deliverability in some cases.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/139989/1/acm212197.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/139989/2/acm212197_am.pd

    Manipulation and Detection of a Trapped Yb+ Ion Hyperfine Qubit

    Full text link
    We demonstrate the use of trapped ytterbium ions as quantum bits for quantum information processing. We implement fast, efficient state preparation and state detection of the first-order magnetic field-insensitive hyperfine levels of 171Yb+, with a measured coherence time of 2.5 seconds. The high efficiency and high fidelity of these operations is accomplished through the stabilization and frequency modulation of relevant laser sources.Comment: 10 pages, 9 figures, 1 tabl

    Impact of 90Y PET gradient-based tumor segmentation on voxel-level dosimetry in liver radioembolization

    Full text link
    Abstract Background The purpose was to validate 90Y PET gradient-based tumor segmentation in phantoms and to evaluate the impact of the segmentation method on reported tumor absorbed dose (AD) and biological effective dose (BED) in 90Y microsphere radioembolization (RE) patients. A semi-automated gradient-based method was applied to phantoms and patient tumors on the 90Y PET with the initial bounding volume for gradient detection determined from a registered diagnostic CT or MR; this PET-based segmentation (PS) was compared with radiologist-defined morphologic segmentation (MS) on CT or MRI. AD and BED volume histogram metrics (D90, D70, mean) were calculated using both segmentations and concordance/correlations were investigated. Spatial concordance was assessed using Dice similarity coefficient (DSC) and mean distance to agreement (MDA). PS was repeated to assess intra-observer variability. Results In phantoms, PS demonstrated high accuracy in lesion volumes (within 15%), AD metrics (within 11%), high spatial concordance relative to morphologic segmentation (DSC > 0.86 and MDA  0.99, MDA < 0.2 mm, AD/BED metrics within 2%). For patients (58 lesions), spatial concordance between PS and MS was degraded compared to in-phantom (average DSC = 0.54, average MDA = 4.8 mm); the average mean tumor AD was 226 ± 153 and 197 ± 138 Gy, respectively for PS and MS. For patient AD metrics, the best Pearson correlation (r) and concordance correlation coefficient (ccc) between segmentation methods was found for mean AD (r = 0.94, ccc = 0.92), but worsened as the metric approached the minimum dose (for D90, r = 0.77, ccc = 0.69); BED metrics exhibited a similar trend. Patient PS showed low intra-observer variability (average DSC = 0.81, average MDA = 2.2 mm, average AD/BED metrics within 3.0%). Conclusions 90Y PET gradient-based segmentation led to accurate/robust results in phantoms, and showed high concordance with MS for reporting mean tumor AD/BED in patients. However, tumor coverage metrics such as D90 exhibited worse concordance between segmentation methods, highlighting the need to standardize segmentation methods when reporting AD/BED metrics from post-therapy 90Y PET. Estimated differences in reported AD/BED metrics due to segmentation method will be useful for interpreting RE dosimetry results in the literature including tumor response data.https://deepblue.lib.umich.edu/bitstream/2027.42/146544/1/40658_2018_Article_230.pd

    Quantum Interference of Photon Pairs from Two Trapped Atomic Ions

    Get PDF
    We collect the fluorescence from two trapped atomic ions, and measure quantum interference between photons emitted from the ions. The interference of two photons is a crucial component of schemes to entangle atomic qubits based on a photonic coupling. The ability to preserve the generated entanglement and to repeat the experiment with the same ions is necessary to implement entangling quantum gates between atomic qubits, and allows the implementation of protocols to efficiently scale to larger numbers of atomic qubits.Comment: 4 pages, 4 figure

    Efficient Photoionization-Loading of Trapped Cadmium Ions with Ultrafast Pulses

    Get PDF
    Atomic cadmium ions are loaded into radiofrequency ion traps by photoionization of atoms in a cadmium vapor with ultrafast laser pulses. The photoionization is driven through an intermediate atomic resonance with a frequency-quadrupled mode-locked Ti:Sapphire laser that produces pulses of either 100 fsec or 1 psec duration at a central wavelength of 229 nm. The large bandwidth of the pulses photoionizes all velocity classes of the Cd vapor, resulting in high loading efficiencies compared to previous ion trap loading techniques. Measured loading rates are compared with a simple theoretical model, and we conclude that this technique can potentially ionize every atom traversing the laser beam within the trapping volume. This may allow the operation of ion traps with lower levels of background pressures and less trap electrode surface contamination. The technique and laser system reported here should be applicable to loading most laser-cooled ion species.Comment: 11 pages, 12 figure

    Quantum Networking with Photons and Trapped Atoms

    Get PDF
    Distributed quantum information processing requires a reliable quantum memory and a faithful carrier of quantum information. Atomic qubits have very long coherence times and are thus excellent candidates for quantum information storage, whereas photons are ideal for the transport of quantum information as they can travel long distances with a minimum of decoherence. We discuss the theoretical and experimental combination of these two systems and their use for not only quantum information transfer but also scalable quantum computation architectures

    Anxiety and depression in patients with gastrointestinal cancer: does knowledge of cancer diagnosis matter?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Gastrointestinal cancer is the first leading cause of cancer related deaths in men and the second among women in Iran. An investigation was carried out to examine anxiety and depression in this group of patients and to investigate whether the knowledge of cancer diagnosis affect their psychological distress.</p> <p>Methods</p> <p>This was a cross sectional study of anxiety and depression in patients with gastrointestinal cancer attending to the Tehran Cancer Institute. Anxiety and depression was measured using the Hospital Anxiety and Depression Scale (HADS). This is a widely used valid questionnaire to measure psychological distress in cancer patients. Demographic and clinical data also were collected to examine anxiety and depression in sub-group of patients especially in those who knew their cancer diagnosis and those who did not.</p> <p>Results</p> <p>In all 142 patients were studied. The mean age of patients was 54.1 (SD = 14.8), 56% were male, 52% did not know their cancer diagnosis, and their diagnosis was related to esophagus (29%), stomach (30%), small intestine (3%), colon (22%) and rectum (16%). The mean anxiety score was 7.6 (SD = 4.5) and for the depression this was 8.4 (SD = 3.8). Overall 47.2% and 57% of patients scored high on both anxiety and depression. There were no significant differences between gender, educational level, marital status, cancer site and anxiety and depression scores whereas those who knew their diagnosis showed a significant higher degree of psychological distress [mean (SD) anxiety score: knew diagnosis 9.1 (4.2) vs. 6.3 (4.4) did not know diagnosis, P < 0.001; mean (SD) depression score: knew diagnosis 9.1 (4.1) vs. 7.9 (3.6) did not know diagnosis, P = 0.05]. Performing logistic regression analysis while controlling for demographic and clinical variables studied the results indicated that those who knew their cancer diagnosis showed a significant higher risk of anxiety [OR: 2.7, 95% CI: 1.1–6.8] and depression [OR: 2.8, 95% CI: 1.1–7.2].</p> <p>Conclusion</p> <p>Psychological distress was higher in those who knew their cancer diagnosis. It seems that the cultural issues and the way we provide information for cancer patients play important role in their improved or decreased psychological well-being.</p
    • 

    corecore