Effects of hospital facilities on patient outcomes after cancer surgery: an international, prospective, observational study
Background Early death after cancer surgery is higher in low-income and middle-income countries (LMICs) compared with in high-income countries, yet the impact of facility characteristics on early postoperative outcomes is unknown. The aim of this study was to examine the association between hospital infrastructure, resource availability, and processes on early outcomes after cancer surgery worldwide.Methods A multimethods analysis was performed as part of the GlobalSurg 3 study-a multicentre, international, prospective cohort study of patients who had surgery for breast, colorectal, or gastric cancer. The primary outcomes were 30-day mortality and 30-day major complication rates. Potentially beneficial hospital facilities were identified by variable selection to select those associated with 30-day mortality. Adjusted outcomes were determined using generalised estimating equations to account for patient characteristics and country-income group, with population stratification by hospital.Findings Between April 1, 2018, and April 23, 2019, facility-level data were collected for 9685 patients across 238 hospitals in 66 countries (91 hospitals in 20 high-income countries; 57 hospitals in 19 upper-middle-income countries; and 90 hospitals in 27 low-income to lower-middle-income countries). The availability of five hospital facilities was inversely associated with mortality: ultrasound, CT scanner, critical care unit, opioid analgesia, and oncologist. After adjustment for case-mix and country income group, hospitals with three or fewer of these facilities (62 hospitals, 1294 patients) had higher mortality compared with those with four or five (adjusted odds ratio [OR] 3.85 [95% CI 2.58-5.75]; p<0.0001), with excess mortality predominantly explained by a limited capacity to rescue following the development of major complications (63.0% vs 82.7%; OR 0.35 [0.23-0.53]; p<0.0001). Across LMICs, improvements in hospital facilities would prevent one to three deaths for every 100 patients undergoing surgery for cancer.Interpretation Hospitals with higher levels of infrastructure and resources have better outcomes after cancer surgery, independent of country income. Without urgent strengthening of hospital infrastructure and resources, the reductions in cancer-associated mortality associated with improved access will not be realised
A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)
Meeting abstrac
Minimal information for studies of extracellular vesicles (MISEV2023): From basic to advanced approaches
Extracellular vesicles (EVs), through their complex cargo, can reflect the state of their cell of origin and change the functions and phenotypes of other cells. These features indicate strong biomarker and therapeutic potential and have generated broad interest, as evidenced by the steady year-on-year increase in the numbers of scientific publications about EVs. Important advances have been made in EV metrology and in understanding and applying EV biology. However, hurdles remain to realising the potential of EVs in domains ranging from basic biology to clinical applications due to challenges in EV nomenclature, separation from non-vesicular extracellular particles, characterisation and functional studies. To address the challenges and opportunities in this rapidly evolving field, the International Society for Extracellular Vesicles (ISEV) updates its 'Minimal Information for Studies of Extracellular Vesicles', which was first published in 2014 and then in 2018 as MISEV2014 and MISEV2018, respectively. The goal of the current document, MISEV2023, is to provide researchers with an updated snapshot of available approaches and their advantages and limitations for production, separation and characterisation of EVs from multiple sources, including cell culture, body fluids and solid tissues. In addition to presenting the latest state of the art in basic principles of EV research, this document also covers advanced techniques and approaches that are currently expanding the boundaries of the field. MISEV2023 also includes new sections on EV release and uptake and a brief discussion of in vivo approaches to study EVs. Compiling feedback from ISEV expert task forces and more than 1000 researchers, this document conveys the current state of EV research to facilitate robust scientific discoveries and move the field forward even more rapidly
Estimating the Intensity Equations for Rain Intensity Frequency Curves (Mosul /Iraq)
The relationship between the rainfall intensity, duration, and frequency (IDF) is widely used in water resources engineering in designing hydraulic structures, such as culverts and sewage systems, and for reducing and controlling floods. In this study, the curves of (IDF) were found for five rain stations registered in different regions in northern Iraq, i.e., Mosul, Tal-Afar, Sinjar, Rabia, and Tal-Abta, and for different periods extending from 1990 to 2019. The Indian Meteorological Department (IMD) empirical equation was utilized to obtain data during short periods, i.e., 10, 20, 30, 60, 120, 180, 360, 720, and 1440 minutes. Also, three probability distributions were used: the Gumble Distribution, the Log Pearson Type III Distribution, and the Log-Normal Distribution, for various return periods (2, 5, 10, 25, 50, and 100) years. Easy fit 5.6 software includes the tests (Kolmogorov-Smirnov, Anderson -Darling (AD), Chi-Squared (χ2)) was used to determine the most suitable distribution for the observed data among the three used distributions. The results demonstrated an insignificant difference between the three applied distributions and the statistics values that fell within the significance level, with priority to the Log Pearson-III distribution
Effects of positive end-expiratory pressure strategy in supine and prone position on lung and chest wall mechanics in acute respiratory distress syndrome
In acute respiratory distress syndrome (ARDS) patients, it has recently been proposed to set positive end-expiratory pressure (PEEP) by targeting end-expiratory transpulmonary pressure. This approach, which relies on the measurement of absolute esophageal pressure (Pes), has been used in supine position (SP) and has not been investigated in prone position (PP). Our purposes were to assess Pes-guided strategy to set PEEP in SP and in PP as compared with a PEEP/FIO table and to explore the early (1 h) and late (16 h) effects of PP on lung and chest wall mechanics. We performed a prospective, physiologic study in two ICUs in university hospitals on ARDS patients with PaO/FIO < 150 mmHg. End-expiratory Pes (Pes,ee) was measured in static (zero flow) condition. Patients received PEEP set according to a PEEP/FO table then according to the Pes-guided strategy targeting a positive (3 ± 2 cmHO) static end-expiratory transpulmonary pressure in SP. Then, patients were turned to PP and received same amount of PEEP from PEEP/FO table then Pes-guided strategy. Respiratory mechanics, oxygenation and end-expiratory lung volume (EELV) were measured after 1 h of each PEEP in each position. For the rest of the 16-h PP session, patients were randomly allocated to either PEEP strategy with measurements done at the end. Thirty-eight ARDS patients (27 male), mean ± SD age 63 ± 13 years, were included. There were 33 primary ARDS and 26 moderate ARDS. PaO/FIO ratio was 120 ± 23 mmHg. At same PEEP/FIO table-related PEEP, Pes,ee averaged 9 ± 4 cmHO in both SP and PP (P = 0.88). With PEEP/FO table and Pes-guided strategy, PEEP was 10 ± 2 versus 12 ± 4 cmHO in SP and 10 ± 2 versus 12 ± 5 cmHO in PP (PEEP strategy effect P = 0.05, position effect P = 0.96, interaction P = 0.96). With the Pes-guided strategy, chest wall elastance increased regardless of position. Lung elastance and transpulmonary driving pressure decreased in PP, with no effect of PEEP strategy. Both PP and Pes-guided strategy improved oxygenation without interaction. EELV did not change with PEEP strategy. At the end of PP session, respiratory mechanics did not vary but EELV and PaO/FO increased while PaCO decreased. There was no impact of PP on Pes measurements. PP had an immediate improvement effect on lung mechanics and a late lung recruitment effect independent of PEEP strategy
Low-pressure support vs automatic tube compensation during spontaneous breathing trial for weaning
BACKGROUND: During spontaneous breathing trial, low-pressure support is thought to compensate for endotracheal tube resistance, but it actually should provide overassistance. Automatic tube compensation is an option available in the ventilator to compensate for flow-resistance of endotracheal tube. Its effects on patient effort have been poorly investigated. We aimed to compare the effects of low-pressure support and automatic tube compensation during spontaneous breathing trial on breathing power and lung ventilation distribution. RESULTS: We performed a randomized crossover study in 20 patients ready to wean. Each patient received both methods for 30 min separated by baseline ventilation: pressure support 0 cmH2O and automatic tube compensation 100% in one period and pressure support 7 cmH2O without automatic tube compensation in the other period, a 4 cmH2O positive end-expiratory pressure being applied in each. Same ventilator brand (Evita XL, Draeger, Germany) was used. Breathing power was assessed from Campbell diagram with esophageal pressure, airway pressure, flow and volume recorded by a data logger. Lung ventilation distribution was assessed by using electrical impedance tomography (Pulmovista, Draeger, Germany). During the last 2 min of low-pressure support and automatic compensation period breathing power and lung ventilation distribution were measured on each breath. Breathing power generated by the patient's respiratory muscles was 7.2 (4.4-9.6) and 9.7 (5.7-21.9) J/min in low-pressure support and automatic tube compensation periods, respectively (P = 0.011). Lung ventilation distribution was not different between the two methods. CONCLUSIONS: We found that ATC was associated with higher breathing power than low PS during SBT without altering the distribution of lung ventilation
Lung and chest wall mechanics in patients with acute respiratory distress syndrome, expiratory flow limitation, and airway closure
Tidal expiratory flow limitation (EFL), which may herald airway closure (AC), is a mechanism of loss of aeration in ARDS. In this prospective, short-term, two-center study, we measured static and dynamic chest wall (Est,cw and Edyn,cw) and lung (Est,L and Edyn,L) elastance with esophageal pressure, EFL, and AC at 5 cmH(2)O positive end-expiratory pressure (PEEP) in intubated, sedated, and paralyzed ARDS patients. For EFL determination, we used the atmospheric method and a new device allowing comparison of tidal flow during expiration to PEEP and to atmosphere. AC was validated when airway opening pressure (AOP) assessed from volume-pressure curve was found greater than PEEP by at least 1 cmH(2)O. EFL was defined whenever flow did not increase between exhalation to PEEP and to atmosphere over all or part of expiration. Elastance values were expressed as percentage of normal predicted values (%N). Among the 25 patients included, eight had EFL (32%) and 13 AOP (52%). Between patients with and without EFL Edyn,cw [median (1st to 3rd quartiles)] was 70 (16-127) and 102 (70-142) %N (P = 0.32) and Edyn,L338 (332-763) and 224 (160-275) %N (P \textless 0.001). The corresponding values for Est,cw and Est,L were 70 (56-88) and 85 (64-103) %N (P = 0.35) and 248 (206-348) and 170 (144-195) (P = 0.02), respectively. Dynamic E(L) had an area receiver operating characteristic curve of 0.88 [95% confidence intervals 0.83-0.92] for EFL and 0.74[0.68-0.79] for AOP. Higher Edyn,L was accurate to predict EFL in ARDS patients; AC can occur independently of EFL, and both should be assessed concurrently in ARDS patients.NEW & NOTEWORTHY Expiratory flow limitation (EFL) and airway closure (AC) were observed in 32% and 52%, respectively, of 25 patients with ARDS investigated during mechanical ventilation in supine position with a positive end-expiratory pressure of 5 cmH(2)O. The performance of dynamic lung elastance to detect expiratory flow limitation was good and better than that to detect airway closure. The vast majority of patients with EFL also had AC; however, AC can occur in the absence of EFL
Monocyte CD169 expression in COVID-19 patients upon intensive care unit admission
International audienceDuring the second surge of COVID-19 in France (fall 2020), we assessed the expression of monocyte CD169 (i.e., Siglec-1, one of the numerous IFN-stimulated genes) upon admission to intensive care units of 45 patients with RT-PCR-confirmed SARS-CoV2 pulmonary infection. Overall, CD169 expression was strongly induced on circulating monocytes of COVID-19 patients compared with healthy donors and patients with bacterial sepsis. Beyond its contribution at the emergency department, CD169 testing may be also helpful for patients' triage at the ICU to rapidly reinforce suspicion of COVID-19 etiology in patients with acute respiratory failure awaiting for PCR results for definitive diagnosis
- …