87 research outputs found

    Reversible low-light induced photoswitching of crowned spiropyran-DO3A complexed with gadolinium(III) ions.

    Get PDF
    Photoswitchable spiropyran has been conjugated to the crowned ring system DO3A, which improves its solubility in dipolar and polar media and stabilizes the merocyanine isomer. Adding the lanthanide ion gadolinium(III) to the macrocyclic ring system leads to a photoresponsive magnetic resonance imaging contrast agent that displays an increased spin-lattice relaxation time (T₁) upon visible light stimulation. In this work, the photoresponse of this photochromic molecule to weak light illumination using blue and green light emitting diodes was investigated, simulating the emission spectra from bioluminescent enzymes. Photon emission rate of the light emitting diodes was changed, from 1.75 × 10Âč⁶ photons·s⁻Âč to 2.37 × 10ÂčÂČ photons·s⁻Âč. We observed a consistent visible light-induced isomerization of the merocyanine to the spiropyran form with photon fluxes as low as 2.37 × 10ÂčÂČ photons·s⁻Âč resulting in a relaxivity change of the compound. This demonstrates the potential for use of the described imaging probes in low light level applications such as sensing bioluminescence enzyme activity. The isomerization behavior of gadolinium(III)-ion complexed and non-complexed spiropyran-DO3A was analyzed in water and ethanol solution in response to low light illumination and compared to the emitted photon emission rate from over-expressed Gaussia princeps luciferase

    Structural Origins of Chiral Second-Order Optical Nonlinearity in Collagen: Amide I Band

    Get PDF
    AbstractThe molecular basis of nonlinear optical (NLO) chiral effects in the amide I region of type I collagen was investigated using sum-frequency generation vibrational spectroscopy; chiral and achiral tensor elements were separated using different input/output beam polarization conditions. Spectra were obtained from native rat tail tendon (RTT) collagen and from cholesteric liquid crystal-like (LC) type I collagen films. Although RTT and LC collagen both possess long-range order, LC collagen lacks the complex hierarchical organization of RTT collagen. Their spectra were compared to assess the role of such organization in NLO chirality. No significant differences were observed between RTT and LC with respect to chiral or achiral spectra. These findings suggest that amide I NLO chiral effects in type I collagen assemblies arise predominantly from the chiral organization of amide chromophores within individual collagen molecules, rather than from supramolecular structures. The study suggests that sum-frequency generation vibrational spectroscopy may be uniquely valuable in exploring fundamental aspects of chiral nonlinearity in complex macromolecular structures

    The DUNE far detector vertical drift technology. Technical design report

    Get PDF
    DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals

    Real-Time Visualization of Tissue Surface Biochemical Features Derived from Fluorescence Lifetime Measurements

    No full text
    Fiber based fluorescence lifetime imaging has shown great potential for intraoperative diagnosis and guidance of surgical procedures. Here we describe a novel method addressing a significant challenge for the practical implementation of this technique, i.e., the real-time display of the quantified biochemical or functional tissue properties superimposed on the interrogated area. Specifically, an aiming beam (450 nm) generated by a continuous-wave laser beam was merged with the pulsed fluorescence excitation light in a single delivery/collection fiber and then imaged and segmented using a color-based algorithm. We demonstrate that this approach enables continuous delineation of the interrogated location and dynamic augmentation of the acquired frames with the corresponding fluorescence decay parameters. The method was evaluated on a fluorescence phantom and fresh tissue samples. Current results demonstrate that 34 frames per second can be achieved for augmenting videos of 640 × 512 pixels resolution. Also we show that the spatial resolution of the fluorescence lifetime map depends on the tissue optical properties, the scanning speed, and the frame rate. The dice similarity coefficient between the fluorescence phantom and the reconstructed maps was estimated to be as high as 93%. The reported method could become a valuable tool for augmenting the surgeon's field of view with diagnostic information derived from the analysis of fluorescence lifetime data in real-time using handheld, automated, or endoscopic scanning systems. Current method provides also a means for maintaining the tissue light exposure within safety limits. This study provides a framework for using an aiming beam with other point spectroscopy applications

    Real-Time Visualization of Tissue Surface Biochemical Features Derived From Fluorescence Lifetime Measurements

    No full text
    Fiber based fluorescence lifetime imaging has shown great potential for intraoperative diagnosis and guidance of surgical procedures. Here we describe a novel method addressing a significant challenge for the practical implementation of this technique, i.e. the real-time display of the quantified biochemical or functional tissue properties superimposed on the interrogated area. Specifically, an aiming beam (450 nm) generated by a continuous-wave laser beam was merged with the pulsed fluorescence excitation light in a single delivery/collection fiber and then imaged and segmented using a color-based algorithm. We demonstrate that this approach enables continuous delineation of the interrogated location and dynamic augmentation of the acquired frames with the corresponding fluorescence decay parameters. The method was evaluated on a fluorescence phantom and fresh tissue samples. Current results demonstrate that 34 frames per second can be achieved for augmenting videos of 640×512 pixels resolution. Also we show that the spatial resolution of the fluorescence lifetime map depends on the tissue optical properties, the scanning speed, and the frame rate. The dice similarity coefficient between the fluorescence phantom and the reconstructed maps was estimated to be as high as 93%. The reported method could become a valuable tool for augmenting the surgeon’s field of view with diagnostic information derived from the analysis of fluorescence lifetime data in real-time using handheld, automated, or endoscopic scanning systems. Current method provides also a means for maintaining the tissue light exposure within safety limits. This study provides a framework for using an aiming beam with other point spectroscopy applications

    Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    No full text
    We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures

    Energy harvesting photodiodes with integrated 2D diffractive storage capacitance

    No full text
    Integrating photodiodes with logic and exploiting on-die interconnect capacitance for energy storage can enable new, low-cost energy harvesting wireless systems. To further explore the tradeoffs between optical efficiency and capacitive energy storage for integrated photodiodes, an array of photovoltaics with various diffractive storage capacitors was designed in TSMC’s 90 nm CMOS technology. Transient effects from interfacing the photodiodes with switching regulators were examined. A quantitative comparison between 90 nm and 0.35 ÎŒm CMOS logic processes for energy harvesting capabilities was carried out. Measurements show an increase in power generation for the newer CMOS technology, however at the cost of reduced output voltage

    Fluorescence Lifetime Imaging and Intravascular Ultrasound: Co-Registration Study Using Ex Vivo Human Coronaries

    No full text
    Fluorescence lifetime imaging (FLIM) has demonstrated potential for robust assessment of atherosclerotic plaques biochemical composition and for complementing conventional intravascular ultrasound (IVUS), which provides information on plaque morphology. The success of such a bi-modal imaging modality depends on accurate segmentation of the IVUS images and proper angular registration between these two modalities. This paper reports a novel IVUS segmentation methodology addressing this issue. The image preprocessing consisted of denoising, using the Wiener filter, followed by image smoothing, implemented through the application of the alternating sequential filter on the edge separability metric images. Extraction of the lumen/intima and media/adventitia boundaries was achieved by tracing the gray-scale peaks over the A-lines of the IVUS preprocessed images. Cubic spline interpolation, in both cross-sectional and longitudinal directions, ensured boundary smoothness and continuity. The detection of the guide-wire artifact in both modalities is used for angular registration. Intraluminal studies were conducted in 13 ex vivo segments of human coronaries. The IVUS segmentation accuracy was assessed against independent manual tracings, providing 91.82% sensitivity and 97.55% specificity. The proposed methodology makes the bi-modal FLIM and IVUS approach feasible for comprehensive intravascular diagnosis by providing co-registered biochemical and morphological information of atherosclerotic plaques
    • 