34 research outputs found

    Magnesium 2000 postmarket evaluation : Guideline adherence and intraprocedural performance of a sirolimus-eluting resorbable magnesium scaffold

    Get PDF
    Background The Magmaris bioresorbable magnesium scaffold was successfully tested in in-vitro and in clinical premarket studies. Subsequently the Magmaris postmarket program aimed to review intraprocedural data of at least 2000 patients to assess user preferences, guideline adherence and intraprocedural performance in clinical routine. Methods This international multicentre survey encompasses data from 356 hospitals across 45 countries. As part of the certification for Magmaris implantation, each hospital had to complete consecutive post-market evaluation forms of their first 10 commercial Magmaris patients. Results From June 2016 to May 2018, data on 2018 implantations were collected. Main reasons for selecting Magmaris was patients' life expectancy (67%, n = 1359) and low or not calcified lesions, (67%, n = 1357). Magmaris was successfully deployed in 99% of cases (n = 1995), predilatation was performed in 95% (n = 1922) and post-dilatation in 87% (n = 1756). Physicians rated the overall performance and the pushability as good or very good in 96% of cases (n = 1799). Guide wire friction, trackability, and conformability were rated as good or very good in 94% of cases, and crossability in 93%. The majority of patients were scheduled to receive dual antiplatelet therapy for up to 12 months. Conclusion Generally, implantation guidelines were adhered to and theoretical advantages of the metal scaffold observed in in-vitro tests have translated into practice with good intraprocedural performance outcomes, confirming the controlled roll-out of this novel technology into clinical practice. (C) 2019 The Authors. Published by Elsevier Inc.Peer reviewe

    Polymer-based or polymer-free stents in patients at high bleeding risk

    Get PDF
    Background: polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. Methods: in an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. Results: a total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). Conclusions: among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.)

    BIOSOLVE-IV-registry: Safety and performance of the Magmaris scaffold: 12-month outcomes of the first cohort of 1,075 patients

    No full text
    OBJECTIVES: We aimed to assess the safety and performance of the Magmaris sirolimus-eluting bioresorbable magnesium scaffold in a large patient population. BACKGROUND: Magmaris has shown good outcomes in small-sized controlled trials, but further data are needed to confirm its usability, safety, and performance. METHODS: BIOSOLVE-IV is an international, single arm, multicenter registry including patients with a maximum of two single de novo lesions. Follow-up is scheduled up to 5 years; the primary outcome is target lesion failure (TLF) at 12 months. RESULTS: A total of 1,075 patients with 1,121 lesions were enrolled. Mean patient age was 61.3 ± 10.5 years and 19.2% (n = 206) presented with non-ST-elevation myocardial infarction (NSTEMI). Lesions were 3.2 ± 0.3 mm in diameter and 14.9 ± 4.2 mm long; 5.1% (n = 57) were bifurcation lesions. Device success was 97.3% (n = 1,129) and procedure success 98.9% (n = 1,063). The Kaplan-Meier estimate of TLF at 12 months was 4.3% [95% confidence interval, CI: 3.2, 5.7] consisting of 3.9% target lesion revascularizations, 0.2% cardiac death, and 1.1% target-vessel myocardial infarction. Definite/probable scaffold thrombosis occurred in five patients (0.5% [95% CI: 0.2, 1.1]), thereof four after early discontinuation of antiplatelet/anticoagulation therapy. CONCLUSION: BIOSOLVE-IV confirms the safety and performance of the Magmaris scaffold in a large population with excellent device and procedure success and a very good safety profile up to 12 months in a low-risk population.status: publishe

    Design and Rationale of the BIOFLOW-DAPT Trial: a Prospective, Randomized, Multicenter Study to Assess the Safety of the Orsiro Mission Stent Compared to the Resolute Onyx Stent in Subjects at High Risk for Bleeding in Combination with 1-Month Dual Antiplatelet Therapy.

    No full text
    The optimal duration of dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients undergoing percutaneous coronary intervention (PCI) with implantation of the Orsiro Mission stent remains unclear. The BIOFLOW-DAPT (clinicaltrials.gov, NCT04137510) trial is a prospective, multi-center, randomized controlled study designed to assess the safety of the Orsiro Mission versus the Resolute Onyx stent in HBR patients. Patients are treated with DAPT (aspirin and a P2Y12 inhibitor) for 1 month, followed by a single antiplatelet therapy (SAPT). The primary endpoint is the composite of cardiac death, myocardial infarction, and definite or probable stent thrombosis at 1 year. With a final sample size of 1948 HBR patients, this study is powered to assess the noninferiority of the Orsiro Mission stent with respect to the primary study endpoint. The BIOFLOW-DAPT is the first randomized clinical trial investigating 1-month DAPT duration in HBR patients after implantation of the Orsiro Mission stent.Trial Registration: ClinicalTrials.gov number, NCT04137510 Study design and key features. Patient selection starts before the index PCI, when consented patients will be randomized to the Orsiro Mission or the Resolute Onyx stent with mandated 1-month DAPT. At 1 month, eligibility is reassessed and if met, patients will discontinue DAPT and continue with P2Y12 inhibitor or aspirin monotherapy. PCI, percutaneous coronary intervention; DAPT, dual antiplatelet therapy; DES, drug-eluting stent; HBR, high bleeding risk; P2Y12i, P2Y12 inhibitor; ST, stent thrombosis
    corecore