1,452 research outputs found

    EAPC task force on education for psychologists in palliative care

    Get PDF
    It is argued that psychological aspects of care and psychosocial problems are essential components of palliative care. However, the provision of appropriate services remains somewhat arbitrary. Unlike medical and nursing care, which are clearly delivered by doctors and nurses respectively, psychological and psychosocial support in palliative care are not assigned exclusively to psychologists. It is generally expected that all professionals working in palliative care should have some knowledge of the psychological dynamics in terminal illness, as well as skills in communication and psychological risk assessment. On the one hand, palliative care education programmes for nurses and doctors comprise a considerable amount of psychological and psychosocial content. On the other hand, only a few palliative care associations provide explicit information on the role and tasks of psychologists in palliative care. Psychologists’ associations do not deal much with this issue either. If they refer to it at all, it is in the context of the care of the aged, end-of-life care or how to deal with grief

    Develop and test fuel cell powered on-site integrated total energy system

    Get PDF
    Test results are presented for a 24 cell, two sq ft (4kW) stack. This stack is a precursor to a 25kW stack that is a key milestone. Results are discussed in terms of cell performance, electrolyte management, thermal management, and reactant gas manifolding. The results obtained in preliminary testing of a 50kW methanol processing subsystem are discussed. Subcontracting activities involving application analysis for fuel cell on site integrated energy systems are updated

    Develop and test fuel cell powered on-site integrated total energy systems: Phase 3, full-scale power plant development

    Get PDF
    A 25 cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 6000 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests were carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. In light of the favorable results obtained, a 25kW stack that will contain 175 cells of the same size is being constructed using the same technology base. The components for the 25kW stack have been completed. A methanol steam reformer with a design output equivalent to 50kW has been constructed to serve as a hydrogen generator for the 25kW stack. This reformer and the balance of the fuel processing sub system are currently being tested and debugged. The stack technology development program focused on cost reduction in bipolar plates, nonmetallic cooling plates, and current collecting plates; more stable cathode catalyst support materials; more corrosion resistant metal hardware; and shutdown/start up tolerance

    Develop and test fuel cell powered on-site integrated total energy systems

    Get PDF
    On-going testing of an 11 cell, 10.7 in. x 14 in. stack (about 1 kW) reached 2600 hours on steady load. Nonmetallic cooling plates and an automated electrolyte replenishment system continued to perform well. A 10 cell, 10.7 in. x 14 in. stack was constructed with a modified electrolyte matrix configuration for the purpose of reducing cell IR loss. The desired effect was achieved, but the general cell performance level was irregular. Evaluation is continuing. Preparations for a long term 25 cell, 13 in. x 23 in. test stack (about 4 kW) approached completion. Start up in early May 1984 is expected

    Develop and test fuel cell powered on site integrated total energy sysems: Phase 3: Full-scale power plant development

    Get PDF
    A 25-cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 8300 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests have been carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. A 25kW stack containing 175 cells of the same size and utilizing a technology base representative of the 25-cell stacks has been constructed and is undergoing initial testing. A third 4kW stack is being prepared, and this stack will incorporate several new technology features

    Comparison of Upscaled Models for Multistage Mass Discharge from DNAPL Source Zones

    Get PDF
    Analytical upscaled models that can describe the depletion of dense nonaqueous phase liquids (DNAPLs) and the associated mass discharge are a practical alternative to computationally demanding and data-intensive multiphase numerical simulators. A major shortcoming of most existing upscaled models is that they cannot reproduce the nonmonotonic, multistage effluent concentrations often observed in experiments and numerical simulations. Upscaled models that can produce multistage concentrations either require calibration, which increases the cost of applying them in the field, or use dual-domain conceptual models that may not apply for spatially complex source zones. In this study, a new upscaled model is presented that can describe the nonmonotonic, multistage average concentrations emanating from complex DNAPL source zones. This is achieved by explicitly considering the temporal evolution of three source zone parameters, namely source zone projected area, the average of local-scale DNAPL saturations, and the average of local-scale aqueous relative permeability, without using empirical parameters. The model is evaluated for two real and twelve hypothetical centimeter-scale complex source zones. The proposed model captures the temporal variations in concentrations better than an empirical model and a dual-domain ganglia- to-pool ratio model. The results provide evidence that effluent concentrations downgradient of DNAPL source zones are controlled by the evolution of the aforementioned macroscopic parameters. This knowledge can be useful for the interpretation of field observations of effluent concentrations downstream of DNAPL source zones, and for the development of predictive upscaled models. Advances in DNAPL characterization techniques are needed to quantify these macroscopic parameters that can be used to guide DNAPL remediation efforts

    Reconstructing Dryopteris “semicristata” (Dryopteridaceae): Molecular profiles of tetraploids verify their undiscovered diploid ancestor

    Get PDF
    This is the publisher's version, also available electronically from http://www.amjbot.org.• Premise of the study: Discovering missing ancestors is essential to understanding the evolutionary history of biodiversity on Earth. Evidence from extinct species can provide links for reconstructing intricate patterns of reticulate relationships among extant descendents. When fossils are unavailable and other evidence yields competing hypotheses to explain species ancestry, data from proteins and DNA can help resolve conflicts and generate novel perspectives. The identity of a parent shared by two tetraploid species in the cosmopolitan fern genus Dryopteris has remained elusive for more than 50 years. Based on available data, four hypotheses were developed previously, each providing a different resolution to this uncertainty. • Methods: New molecular evidence from studies of isozymes and restriction site analysis of chloroplast DNA tested the competing hypotheses about the diploid ancestors of these two extant Dryopteris polyploids. • Key results: The results falsify two of the hypotheses, resolve the uncertainty in the third, and support the fourth. • Conclusions: Our data validate the prior existence of Dryopteris “semicristata,” which was proposed 38 years ago as a diploid progenitor of the allotetraploids D. cristata and D. carthusiana but has never been collected. After developing a phylogeny using the new molecular data, we describe a plausible morphology for D. “semicristata” by extrapolating likely character states from related extant species

    Terahertz frequency standard based on three-photon coherent population trapping

    Full text link
    A scheme for a THz frequency standard based on three-photon coherent population trapping in stored ions is proposed. Assuming the propagation directions of the three lasers obey the phase matching condition, we show that stability of few 1014^{-14} at one second can be reached with a precision limited by power broadening to 101110^{-11} in the less favorable case. The referenced THz signal can be propagated over long distances, the useful information being carried by the relative frequency of the three optical photons.Comment: article soumis a PRL le 21 mars 2007, accepte le 10 mai, version 2 (24/05/2007

    Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

    Get PDF
    Operating experience with a 5kW methanol-air integrated system is described. On-going test results for a 24-cell, two-sq ft (4kW) stack are reported. The main activity for this stack is currently the evaluation of developmental non-metalic cooling plates. Single-cell test results are presented for a promising developmental cathode catalyst
    corecore