19 research outputs found

    Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments

    Get PDF
    Purpose: The impact of multileaf collimator (MLC) design and IMRT technique on plan quality and delivery improvements for head-and-neck and meningioma patients is compared in a planning study. Material and methods: Ten previously treated patients (5 head-and-neck, 5 meningioma) were re-planned for step-and-shoot IMRT (ssIMRT),sliding window IMRT (dMLC) and VMAT using the MLCi2 without (-) and with (+) interdigitation and the Agility-MLC attached to an Elekta 6MV linac. This results in nine plans per patient. Consistent patient individual optimization parameters are used. Plans are generated using the research tool Hyperion V2.4 (equivalent to Elekta Monaco 3.2) with hard constraints for critical structures and objectives for target structures. For VMAT plans, the improved segment shape optimization is used. Critical structures are evaluated based on QUANTEC criteria. PTV coverage is compared by EUD, D-mean, homogeneity and conformity. Additionally, MU/plan, treatment times and number of segments are evaluated. Results: As constrained optimization is used, all plans fulfill the hard constraints. Doses to critical structures do not differ more than 1Gy between the nine generated plans for each patient. Only larynx, parotids and eyes differ up to 1.5Gy (D-mean or D-max) or 7 % (volume-constraint) due to (1) increased scatter,(2) not avoiding structures when using the full range of gantry rotation and (3) improved leaf sequencing with advanced segment shape optimization for VMAT plans. EUD, Dmean, homogeneity and conformity are improved using the Agility-MLC. However, PTV coverage is more affected by technique. MU increase with the use of dMLC and VMAT, while the MU are reduced by using the Agility-MLC. Fastest treatments are always achieved using Agility-MLC, especially in combination with VMAT. Conclusion: Fastest treatments with the best PTV coverage are found for VMAT plans with Agility-MLC, achieving the same sparing of healthy tissue compared to the other combinations of ssIMRT, dMLC and VMAT with either MLCi2(-/+) or Agility

    Incidental detection of an occult oral malignancy with autofluorescence imaging: a case report

    Get PDF
    BACKGROUND: Autofluorescence imaging is used widely for diagnostic evaluation of various epithelial malignancies. Cancerous lesions display loss of autofluorescence due to malignant changes in epithelium and subepithelial stroma. Carcinoma of unknown primary site presents with lymph node or distant metastasis, for which the site of primary tumour is not detectable. We describe here the use of autofluorescence imaging for detecting a clinically innocuous appearing occult malignancy of the palate which upon pathological examination was consistent with a metastatic squamous cell carcinoma. CASE DESCRIPTION: A submucosal nodule was noted on the right posterior hard palate of a 59-year-old white female during clinical examination. Examination of this lesion using a multispectral oral cancer screening device revealed loss of autofluorescence at 405 nm illumination. An excisional biopsy of this nodule, confirmed the presence of a metastatic squamous cell carcinoma. Four years ago, this patient was diagnosed with metastatic squamous cell carcinoma of the right mid-jugular lymph node of unknown primary. She was treated with external beam irradiation and remained disease free until current presentation. CONCLUSION: This case illustrates the important role played by autofluorescence tissue imaging in diagnosing a metastatic palatal tumour that appeared clinically innocuous and otherwise would not have been biopsied

    Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments

    Get PDF
    Purpose: The impact of multileaf collimator (MLC) design and IMRT technique on plan quality and delivery improvements for head-and-neck and meningioma patients is compared in a planning study. Material and methods: Ten previously treated patients (5 head-and-neck, 5 meningioma) were re-planned for step-and-shoot IMRT (ssIMRT),sliding window IMRT (dMLC) and VMAT using the MLCi2 without (-) and with (+) interdigitation and the Agility-MLC attached to an Elekta 6MV linac. This results in nine plans per patient. Consistent patient individual optimization parameters are used. Plans are generated using the research tool Hyperion V2.4 (equivalent to Elekta Monaco 3.2) with hard constraints for critical structures and objectives for target structures. For VMAT plans, the improved segment shape optimization is used. Critical structures are evaluated based on QUANTEC criteria. PTV coverage is compared by EUD, D-mean, homogeneity and conformity. Additionally, MU/plan, treatment times and number of segments are evaluated. Results: As constrained optimization is used, all plans fulfill the hard constraints. Doses to critical structures do not differ more than 1Gy between the nine generated plans for each patient. Only larynx, parotids and eyes differ up to 1.5Gy (D-mean or D-max) or 7 % (volume-constraint) due to (1) increased scatter,(2) not avoiding structures when using the full range of gantry rotation and (3) improved leaf sequencing with advanced segment shape optimization for VMAT plans. EUD, Dmean, homogeneity and conformity are improved using the Agility-MLC. However, PTV coverage is more affected by technique. MU increase with the use of dMLC and VMAT, while the MU are reduced by using the Agility-MLC. Fastest treatments are always achieved using Agility-MLC, especially in combination with VMAT. Conclusion: Fastest treatments with the best PTV coverage are found for VMAT plans with Agility-MLC, achieving the same sparing of healthy tissue compared to the other combinations of ssIMRT, dMLC and VMAT with either MLCi2(-/+) or Agility

    Cellular fluorescence of the endogenous photosensitizer protoporphyrin IX following exposure to 5-aminolevulinic acid

    No full text
    Supplying 5-aminolevulinic acid (ALA), a precursor in the biosynthetic pathway to heme from an external source leads to an accumulation of the endogenous fluorescent photosensitizer protoporphyrin IX (PPIX). Following instillation of ALA in the urinary bladder neoplastic tissue can be discerned by fluorescence cystoscopy or treated by illumination with light of an appropriate wavelength. In order to provide a biological rationale for the clinical findings, we have analyzed the capacity of three different cell lines to accumulate PPIX by flow cytometry. Three different urothelial cell lines, normal fibroblasts and endothelial cells were exposed to ALA under varying conditions. Urothelial cell lines J82 and RT4, derived from malignancies of the bladder displayed fluorescence intensities 9- and 16-fold, respectively, above the fluorescence level of the normal urothelial cell line HCV29. Human umbilical cord endothelial cells fluoresced moderately while the fibroblast cell line N1 exhibited a fluorescence level comparable to those of the cancer cells. Fluorescence increased with increasing cell density and was also dependent on the growth of cells as monolayers or multicellular spheroids. Increasing ALA concentrations led to saturation of fluorescence after 4 h of incubation at cell type-specific fluorescence levels obtained at different ALA concentrations. Continuous incubation in medium containing serum resulted in a linear rise of fluorescence during the first 4 h, which was followed by a saturation period (8-24 h) and a renewed rise. In the case of serum depletion, fluorescence intensities were significantly higher and increased linearly during the entire 48 h incubation period.(ABSTRACT TRUNCATED AT 250 WORDS

    Left-sided breast cancer and risks of secondary lung cancer and ischemic heart disease-Effects of modern radiotherapy techniques (vol 194, pg 196, 2017).

    No full text
    Correction to: Strahlenther Onkol 2017 https://doi.org/10.1007/s00066-017-1213-y Unfortunately, during copy editing, the titles of Fig. 2a and 2b were removed. The correct Fig. 2a and 2b are shown below. The original article has been corrected aEuro broken vertical bar

    Left-sided breast cancer and risks of secondary lung cancer and ischemic heart disease.

    No full text
    Modern breast cancer radiotherapy techniques, such as respiratory-gated radiotherapy in deep-inspiration breath-hold (DIBH) or volumetric-modulated arc radiotherapy (VMAT) have been shown to reduce the high dose exposure of the heart in left-sided breast cancer. The aim of the present study was to comparatively estimate the excess relative and absolute risks of radiation-induced secondary lung cancer and ischemic heart disease for different modern radiotherapy techniques. Four different treatment plans were generated for ten computed tomography data sets of patients with left-sided breast cancer, using either three-dimensional conformal radiotherapy (3D-CRT) or VMAT, in free-breathing (FB) or DIBH. Dose-volume histograms were used for organ equivalent dose (OED) calculations using linear, linear-exponential, and plateau models for the lung. A linear model was applied to estimate the long-term risk of ischemic heart disease as motivated by epidemiologic data. Excess relative risk (ERR) and 10-year excess absolute risk (EAR) for radiation-induced secondary lung cancer and ischemic heart disease were estimated for different representative baseline risks. The DIBH maneuver resulted in a significant reduction of the ERR and estimated 10-year excess absolute risk for major coronary events compared to FB in 3D-CRT plans (p = 0.04). In VMAT plans, the mean predicted risk reduction through DIBH was less pronounced and not statistically significant (p = 0.44). The risk of radiation-induced secondary lung cancer was mainly influenced by the radiotherapy technique, with no beneficial effect through DIBH. VMAT plans correlated with an increase in 10-year EAR for radiation-induced lung cancer as compared to 3D-CRT plans (DIBH p = 0.007; FB p = 0.005, respectively). However, the EARs were affected more strongly by nonradiation-associated risk factors, such as smoking, as compared to the choice of treatment technique. The results indicate that 3D-CRT plans in DIBH pose the lowest risk for both major coronary events and secondary lung cancer
    corecore