58 research outputs found

    Negative Selection by an Endogenous Retrovirus Promotes a Higher-Avidity CD4+ T Cell Response to Retroviral Infection

    Get PDF
    Effective T cell responses can decisively influence the outcome of retroviral infection. However, what constitutes protective T cell responses or determines the ability of the host to mount such responses is incompletely understood. Here we studied the requirements for development and induction of CD4+ T cells that were essential for immunity to Friend virus (FV) infection of mice, according to their TCR avidity for an FV-derived epitope. We showed that a self peptide, encoded by an endogenous retrovirus, negatively selected a significant fraction of polyclonal FV-specific CD4+ T cells and diminished the response to FV infection. Surprisingly, however, CD4+ T cell-mediated antiviral activity was fully preserved. Detailed repertoire analysis revealed that clones with low avidity for FV-derived peptides were more cross-reactive with self peptides and were consequently preferentially deleted. Negative selection of low-avidity FV-reactive CD4+ T cells was responsible for the dominance of high-avidity clones in the response to FV infection, suggesting that protection against the primary infecting virus was mediated exclusively by high-avidity CD4+ T cells. Thus, although negative selection reduced the size and cross-reactivity of the available FV-reactive naïve CD4+ T cell repertoire, it increased the overall avidity of the repertoire that responded to infection. These findings demonstrate that self proteins expressed by replication-defective endogenous retroviruses can heavily influence the formation of the TCR repertoire reactive with exogenous retroviruses and determine the avidity of the response to retroviral infection. Given the overabundance of endogenous retroviruses in the human genome, these findings also suggest that endogenous retroviral proteins, presented by products of highly polymorphic HLA alleles, may shape the human TCR repertoire that reacts with exogenous retroviruses or other infecting pathogens, leading to interindividual heterogeneity

    Lipid and Lipoprotein Profiles in Youth With and Without Type 1 Diabetes: The SEARCH for Diabetes in Youth Case-Control Study

    Get PDF
    OBJECTIVE—The purpose of this study was to compare the lipid profile and the prevalence of lipid abnormalities in youth with and without type 1 diabetes and explore the role of glycemic control on the hypothesized altered lipid profile in youth with type 1 diabetes

    Lipid and Lipoprotein Profiles in Youth With and Without Type 1 Diabetes: The SEARCH for Diabetes in Youth Case-Control Study

    Get PDF
    OBJECTIVE The purpose of this study was to compare the lipid profile and the prevalence of lipid abnormalities in youth with and without type 1 diabetes and explore the role of glycemic control on the hypothesized altered lipid profile in youth with type 1 diabetes. RESEARCH DESIGN AND METHODS - We conducted a cross-sectional analysis of 512 youth with type 1 diabetes (mean duration 4.22 years) and 188 healthy control subjects aged 10-22 years in Colorado and South Carolina. SEARCH for Diabetes in Youth (SEARCH) participants with type 1 diabetes and healthy control subjects recruited from primary care offices in the same geographic regions were invited to attend a research visit. Fasting lipid profiles were compared between youth with type 1 diabetes (stratified according to categories of optimal [AlC <7.5%] and suboptimal [AlC ≥7.5%] glycemic control) and healthy nondiabetic youth, using multiple linear and logistic regression. RESULTS - Youth with type 1 diabetes and optimal AlC had lipid concentrations that were similar (total cholesterol, LDL cholesterol, and LDL particle size) or even less atherogenic (HDL cholesterol, non-HDL cholesterol, triglyceride, and triglyceride-to-HDL cholesterol ratio) than those observed in nondiabetic youth, whereas youth with suboptimal glycemic control had elevated standard lipid levels (total cholesterol, LDL cholesterol, and non-HDL cholesterol). Youth with type 1 diabetes also had significantly elevated apolipoprotein B levels and more small, dense LDL particles than nondiabetic youth, regardless of glycemic control. CONCLUSIONS Youth with type 1 diabetes have abnormal lipid levels and atherogenic changes in lipoprotein composition, even after a relatively short disease duration. As in adults, glycemic control is an important mediator of these abnormalities

    After-hours colorectal surgery: a risk factor for anastomotic leakage

    Get PDF
    __Purpose:__ This study aims to increase knowledge of colorectal anastomotic leakage by performing an incidence study and risk factor analysis with new potential risk factors in a Dutch tertiary referral center. __Methods:__ All patients whom received a primary colorectal anastomosis between 1997 and 2007 were selected by means of operation codes. Patient records were studied for population description and risk factor analysis. __Results:__ In total 739 patients were included. Anastomotic leakage (AL) occurred in 64 (8.7%) patients of whom nine (14.1%) died. Median interval between operation and diagnosis was 8 days. The risk for AL was higher as the anastomoses were constructed more distally (p = 0.019). Univariate analysis showed duration of surgery (p = 0.038), BMI (p = 0.001), time of surgery (p = 0.029), prophylactic drainage (p = 0.006) and time under anesthesia (p = 0.012) to be associated to AL. Multivariate analysis showed BMI greater than 30 kg/m2(p = 0.006; OR 2.6 CI 1.3-5.2) and "after hours" construction of an anastomosis (p = 0.030; OR 2.2 CI 1.1-4.5) to be independent risk factors. __Conclusion:__ BMI greater than 30 kg/m2and "after hours" construction of an anastomosis were independent risk factors for colorectal anastomotic leakage

    Consensus Recommendations for the Use of Automated Insulin Delivery (AID) Technologies in Clinical Practice

    Get PDF
    International audienceThe significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past six years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage

    Multicenter, Randomized Trial of a Bionic Pancreas in Type 1 Diabetes

    Get PDF
    BACKGROUND Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P&lt;0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P&lt;0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level

    Consensus recommendations for the use of automated insulin delivery technologies in clinical practice

    Get PDF
    The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage
    corecore