890 research outputs found

    Appearances of screen-detected versus symptomatic colorectal cancers at CT colonography.

    Get PDF
    OBJECTIVES: The aim of this study was to compare the morphology, radiological stage, conspicuity, and computer-assisted detection (CAD) characteristics of colorectal cancers (CRC) detected by computed tomographic colonography (CTC) in screening and symptomatic populations. METHODS: Two radiologists independently analyzed CTC images from 133 patients diagnosed with CRC in (a) two randomized trials of symptomatic patients (35 patients with 36 tumours) and (b) a screening program using fecal occult blood testing (FOBt; 98 patients with 100 tumours), measuring tumour length, volume, morphology, radiological stage, and subjective conspicuity. A commercial CAD package was applied to both datasets. We compared CTC characteristics between screening and symptomatic populations with multivariable regression. RESULTS: Screen-detected CRC were significantly smaller (mean 3.0 vs 4.3 cm, p < 0.001), of lower volume (median 9.1 vs 23.2 cm(3), p < 0.001) and more frequently polypoid (34/100, 34 % vs. 5/36, 13.9 %, p = 0.02) than symptomatic CRC. They were of earlier stage than symptomatic tumours (OR = 0.17, 95 %CI 0.07-0.41, p < 0.001), and were judged as significantly less conspicuous (mean conspicuity 54.1/100 vs. 72.8/100, p < 0.001). CAD detection was significantly lower for screen-detected (77.4 %; 95 %CI 67.9-84.7 %) than symptomatic CRC (96.9 %; 95 %CI 83.8-99.4 %, p = 0.02). CONCLUSIONS: Screen-detected CRC are significantly smaller, more frequently polypoid, subjectively less conspicuous, and less likely to be identified by CAD than those in symptomatic patients. KEY POINTS: • Screen-detected colorectal cancers (CRC) are significantly smaller than symptomatic CRC. • Screening cases are significantly less conspicuous to radiologists than symptomatic tumours. • Screen-detected CRC have different morphology compared to symptomatic tumours (more polypoid, fewer annular). • A commercial computer-aided detection (CAD) system was significantly less likely to note screen-detected CRC

    Cost-effectiveness analysis of 3-D computerized tomography colonography versus optical colonoscopy for imaging symptomatic gastroenterology patients.

    No full text
    BACKGROUND: When symptomatic gastroenterology patients have an indication for colonic imaging, clinicians have a choice between optical colonoscopy (OC) and computerized tomography colonography with three-dimensional reconstruction (3-D CTC). 3-D CTC provides a minimally invasive and rapid evaluation of the entire colon, and it can be an efficient modality for diagnosing symptoms. It allows for a more targeted use of OC, which is associated with a higher risk of major adverse events and higher procedural costs. A case can be made for 3-D CTC as a primary test for colonic imaging followed if necessary by targeted therapeutic OC; however, the relative long-term costs and benefits of introducing 3-D CTC as a first-line investigation are unknown. AIM: The aim of this study was to assess the cost effectiveness of 3-D CTC versus OC for colonic imaging of symptomatic gastroenterology patients in the UK NHS. METHODS: We used a Markov model to follow a cohort of 100,000 symptomatic gastroenterology patients, aged 50 years or older, and estimate the expected lifetime outcomes, life years (LYs) and quality-adjusted life years (QALYs), and costs (£, 2010-2011) associated with 3-D CTC and OC. Sensitivity analyses were performed to assess the robustness of the base-case cost-effectiveness results to variation in input parameters and methodological assumptions. RESULTS: 3D-CTC provided a similar number of LYs (7.737 vs 7.739) and QALYs (7.013 vs 7.018) per individual compared with OC, and it was associated with substantially lower mean costs per patient (£467 vs £583), leading to a positive incremental net benefit. After accounting for the overall uncertainty, the probability of 3-D CTC being cost effective was around 60 %, at typical willingness-to-pay values of £20,000-£30,000 per QALY gained. CONCLUSION: 3-D CTC is a cost-saving and cost-effective option for colonic imaging of symptomatic gastroenterology patients compared with OC

    Long term effects of once-only flexible sigmoidoscopy screening after 17 years of follow-up: the UK Flexible Sigmoidoscopy Screening randomised controlled trail

    Get PDF
    Background: This multicentre randomised trial is examining the effect of single flexible sigmoidoscopy (FS) screening on colorectal cancer (CRC) incidence and mortality. Previous analyses of this and other trials have only reported follow-up after FS for a maximum of 12 years. The objective of this analysis was to examine the long-term effects of FS after 17 years of follow-up. Methods: Between 1994 and 1999, 170,432 eligible men and women, who had indicated on a previous questionnaire that they would probably attend for screening if invited, were randomised to an intervention group (offered FS screening) or a control group (not contacted) in a 1:2 ratio. Randomisation was performed centrally in blocks of 12, and stratified by trial centre, general practice and household type. The primary outcomes were incidence and mortality of CRC. Hazard ratios (HR) and 95% confidence intervals (CI) for CRC incidence and mortality were estimated for intention-to-treat and per-protocol analyses. The trial is registered, number ISRCTN28352761. Findings: This analysis included 170,034 people (57,098 in the intervention and 112,936 in the control group). During screening and a median of 17.1 years’ follow-up, CRC was diagnosed in 1,230 individuals in the intervention and 3,253 in the control group, and 353 vs. 996 respectively died from CRC. In intention-to-treat analyses, CRC incidence was reduced by 26% (HR 0.74, 95% CI 0.70-0.80) and CRC mortality by 30% (HR 0.70, 95% CI 0.62-0.79). In per-protocol analyses, adjusted for non-compliance, CRC incidence and mortality were 35% (HR 0.65, 95% CI 0.59-0.71) and 41% (HR 0.59, 95% CI 0.49-0.70) lower in attenders. Interpretation: A single FS continues to provide substantial protection from CRC diagnosis and death, with protection lasting at least 17 years

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Human blood autoantibodies in the detection of colorectal cancer

    Get PDF
    Colorectal cancer (CRC) is the second most common malignancy in the western world. Early detection and diagnosis of all cancer types is vital to improved prognosis by enabling early treatment when tumours should be both resectable and curable. Sera from 3 different cohorts; 42 sera (21 CRC and 21 matched controls) from New York, USA, 200 sera from Pittsburgh, USA (100 CRC and 100 controls) and 20 sera from Dundee, UK (10 CRC and 10 controls) were tested against a panel of multiple tumour-associated antigens (TAAs) using an optimised multiplex microarray system. TAA specific IgG responses were interpo- lated against the internal IgG standard curve for each sample. Individual TAA specific responses were examined in each cohort to determine cutoffs for a robust initial scoring method to establish sensitivity and specificity. Sensitivity and specificity of combinations of TAAs provided good discrimination between cancer-positive and normal serum. The overall sensitivity and specificity of the sample sets tested against a panel of 32 TAAs were 61.1% and 80.9% respectively for 6 antigens; p53, AFP, K RAS, Annexin, RAF1 and NY-CO16. Furthermore, the observed sensitivity in Pittsburgh sample set in different clinical stages of CRC;stageI(n=19),stageII(n=40),stageIII(n=34)andstageIV(n=6)wassimilar (73.6%, 75.0%, 73.5% and 83.3%, respectively), with similar levels of sensitivity for right and left sided CRC. We identified an antigen panel of sufficient sensitivity and specificity for early detection of CRC, based upon serum profiling of autoantibody response using a robust multiplex antigen microarray technology. This opens the possibility of a blood test for screening and detection of early colorectal cancer. However this panel will require further validation studies before they can be proposed for clinical practice

    Factors related to longitudinal adherence in colorectal cancer screening:qualitative research findings

    Get PDF
    Background: The effectiveness of screening in colorectal cancer prevention depends on sustained participation rates. The objective of this study was to explore factors related to the longitudinal adherence of screening behavior in the context of a biennial population-based cancer screening program. Methods: Eight focus groups were conducted with individuals who were invited two or three consecutive times to a population-based colorectal cancer screening program using a fecal occult blood test and who agreed to participate in the program at least once (n = 45). The criteria used to select the study members included adherence to fecal occult blood test maintenance, factors regarding their initial participation in the colorectal cancer screening, sex, and contextual educational level. Results: The participants expressed a high level of satisfaction with the program; however, they showed a low level of understanding with respect to cancer screening. Consulting a general practitioner was cited by all participants as an important factor that mediated their final decision or influenced their behavior as a whole with regard to the program. Fear played a different role in the screening behavior for regular and irregular adherent participants. In the adherent participants, fear facilitated their continued participation in the screening program, whereas for the irregular participants, fear led them to avoid or refuse further screening. Having a close person diagnosed with colorectal cancer was a facilitator for the regular adherent participants. The irregular adherent participants showed some relaxation with respect to screening after a negative result and considered that further screening was no longer necessary. Conclusion: Considering the importance of primary healthcare professionals in the decision regarding sustained participation, it is important to better engage them with cancer screening programs, as well as improve the communication channels to provide accurate and balanced information for both health professionals and individuals.</p

    Operation and performance of the ATLAS Tile Calorimeter in Run 1

    Get PDF
    The Tile Calorimeter is the hadron calorimeter covering the central region of the ATLAS experiment at the Large Hadron Collider. Approximately 10,000 photomultipliers collect light from scintillating tiles acting as the active material sandwiched between slabs of steel absorber. This paper gives an overview of the calorimeter’s performance during the years 2008–2012 using cosmic-ray muon events and proton–proton collision data at centre-of-mass energies of 7 and 8TeV with a total integrated luminosity of nearly 30 fb−1. The signal reconstruction methods, calibration systems as well as the detector operation status are presented. The energy and time calibration methods performed excellently, resulting in good stability of the calorimeter response under varying conditions during the LHC Run 1. Finally, the Tile Calorimeter response to isolated muons and hadrons as well as to jets from proton–proton collisions is presented. The results demonstrate excellent performance in accord with specifications mentioned in the Technical Design Report

    Measurement of the t¯tZ and t¯tW cross sections in proton-proton collisions at √s=13 TeV with the ATLAS detector

    Get PDF
    A measurement of the associated production of a top-quark pair (t¯t) with a vector boson (W, Z) in proton-proton collisions at a center-of-mass energy of 13 TeV is presented, using 36.1  fb−1 of integrated luminosity collected by the ATLAS detector at the Large Hadron Collider. Events are selected in channels with two same- or opposite-sign leptons (electrons or muons), three leptons or four leptons, and each channel is further divided into multiple regions to maximize the sensitivity of the measurement. The t¯tZ and t¯tW production cross sections are simultaneously measured using a combined fit to all regions. The best-fit values of the production cross sections are σt¯tZ=0.95±0.08stat±0.10syst pb and σt¯tW=0.87±0.13stat±0.14syst pb in agreement with the Standard Model predictions. The measurement of the t¯tZ cross section is used to set constraints on effective field theory operators which modify the t¯tZ vertex

    Performance of missing transverse momentum reconstruction with the ATLAS detector using proton–proton collisions at √s = 13 TeV

    Get PDF
    The performance of the missing transverse momentum (EmissT) reconstruction with the ATLAS detector is evaluated using data collected in proton–proton collisions at the LHC at a centre-of-mass energy of 13 TeV in 2015. To reconstruct EmissT, fully calibrated electrons, muons, photons, hadronically decaying τ -leptons, and jets reconstructed from calorimeter energy deposits and charged-particle tracks are used. These are combined with the soft hadronic activity measured by reconstructed charged-particle tracks not associated with the hard objects. Possible double counting of contributions from reconstructed charged-particle tracks from the inner detector, energy deposits in the calorimeter, and reconstructed muons from the muon spectrometer is avoided by applying a signal ambiguity resolution procedure which rejects already used signals when combining the various EmissT contributions. The individual terms as well as the overall reconstructed EmissT are evaluated with various performance metrics for scale (linearity), resolution, and sensitivity to the data-taking conditions. The method developed to determine the systematic uncertainties of the EmissT scale and resolution is discussed. Results are shown based on the full 2015 data sample corresponding to an integrated luminosity of 3.2 fb−1
    corecore