709 research outputs found

    Nasopharyngeal Microbiota Profiles in Rural Venezuelan Children Are Associated With Respiratory and Gastrointestinal Infections

    Get PDF
    BACKGROUND: Recent research suggests that the microbiota affects susceptibility to both respiratory tract infections (RTIs) and gastrointestinal infections (GIIs). In order to optimize global treatment options, it is important to characterize microbiota profiles across different niches and geographic/socioeconomic areas where RTI and GII prevalences are high. METHODS: We performed 16S sequencing of nasopharyngeal swabs from 209 Venezuelan Amerindian children aged 6 weeks-59 months who were participating in a 13-valent pneumococcal conjugate vaccine (PCV13) study. Using random forest models, differential abundance testing, and regression analysis, we determined whether specific bacteria were associated with RTIs or GIIs and variation in PCV13 response. RESULTS: Microbiota compositions differed between children with or without RTIs (P = .018) or GIIs (P = .001). Several species were associated with the absence of infections. Some of these health-associated bacteria are also observed in developed regions, such as Corynebacterium (log2(fold change [FC]) = 3.30 for RTIs and log2(FC) = 1.71 for GIIs), while others are not commonly observed in developed regions, such as Acinetobacter (log2(FC) = 2.82 and log2(FC) = 5.06, respectively). Klebsiella spp. presence was associated with both RTIs (log2(FC) = 5.48) and GIIs (log2(FC) = 7.20). CONCLUSIONS: The nasopharyngeal microbiota of rural Venezuelan children included several bacteria that thrive in tropical humid climates. Interestingly, nasopharyngeal microbiota composition not only differed in children with an RTI but also in those with a GII, which suggests a reciprocal interplay between the 2 environments. Knowledge of region-specific microbiota patterns enables tailoring of preventive and therapeutic approaches

    Inter-method reliability of the modified Rankin Scale in patients with subarachnoid hemorrhage

    Get PDF
    BACKGROUND AND OBJECTIVES: The modified Rankin Scale (mRS) is one of the most frequently used outcome measures in trials in patients with an aneurysmal subarachnoid hemorrhage (aSAH). The assessment method of the mRS is often not clearly described in trials, while the method used might influence the mRS score. The aim of this study is to evaluate the inter-method reliability of different assessment methods of the mRS. METHODS: This is a prospective, randomized, multicenter study with follow-up at 6 weeks and 6 months. Patients aged ≥ 18 years with aSAH were randomized to either a structured interview or a self-assessment of the mRS. Patients were seen by a physician who assigned an mRS score, followed by either the structured interview or the self-assessment. Inter-method reliability was assessed with the quadratic weighted kappa score and percentage of agreement. Assessment of feasibility of the self-assessment was done by a feasibility questionnaire. RESULTS: The quadratic weighted kappa was 0.60 between the assessment of the physician and structured interview and 0.56 between assessment of the physician and self-assessment. Percentage agreement was, respectively, 50.8 and 19.6%. The assessment of the mRS through a structured interview and by self-assessment resulted in systematically higher mRS scores than the mRS scored by the physician. Self-assessment of the mRS was proven feasible. DISCUSSION: The mRS scores obtained with different assessment methods differ significantly. The agreement between the scores is low, although the reliability between the assessment methods is good. This should be considered when using the mRS in clinical trials. TRIAL REGISTRATION: www.trialregister.nl; Unique identifier: NL7859. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00415-021-10880-4

    The 2BFit study: is an unsupervised proprioceptive balance board training programme, given in addition to usual care, effective in preventing ankle sprain recurrences? Design of a Randomized Controlled Trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is strong evidence that athletes have a twofold risk for re-injury after a previous ankle sprain, especially during the first year post-injury. These ankle sprain recurrences could result in disability and lead to chronic pain or instability in 20 to 50% of these cases. When looking at the high rate of ankle sprain recurrences and the associated chronic results, ankle sprain recurrence prevention is important.</p> <p>Objective</p> <p>To evaluate the effect of a proprioceptive balance board training programme on ankle sprain recurrences, that was applied to individual athletes after rehabilitation and treatment by usual care.</p> <p>Methods/Design</p> <p>This study was designed as a randomized controlled trial with a follow-up of one year. Healthy individuals between 12 and 70 years of age, who were actively participating in sports and who had sustained a lateral ankle sprain up to two months prior to inclusion, were eligible for inclusion in the study. The intervention programme was compared to usual care. The intervention programme consisted of an eight-week proprioceptive training, which started after finishing usual care and from the moment that sports participation was again possible. Outcomes were assessed at baseline and every month for 12 months. The primary outcome of this study was the incidence of recurrent ankle injuries in both groups within one year after the initial sprain. Secondary outcomes were severity and etiology of re-injury and medical care. Cost-effectiveness was evaluated from a societal perspective. A process evaluation was conducted for the intervention programme.</p> <p>Discussion</p> <p>The 2BFit trial is the first randomized controlled trial to study the effect of a non-supervised home-based proprioceptive balance board training programme in addition to usual care, on the recurrence of ankle sprains in sports. Results of this study could possibly lead to changes in practical guidelines on the treatment of ankle sprains. Results will become available in 2009.</p> <p>Trial registration</p> <p>ISTRCN34177180.</p

    The capability set for work - correlates of sustainable employability in workers with multiple sclerosis

    Get PDF
    BACKGROUND: The aim of this study was to examine whether work capabilities differ between workers with Multiple Sclerosis (MS) and workers from the general population. The second aim was to investigate whether the capability set was related to work and health outcomes. METHODS: A total of 163 workers with MS from the MS@Work study and 163 workers from the general population were matched for gender, age, educational level and working hours. All participants completed online questionnaires on demographics, health and work functioning. The Capability Set for Work Questionnaire was used to explore whether a set of seven work values is considered valuable (A), is enabled in the work context (B), and can be achieved by the individual (C). When all three criteria are met a work value can be considered part of the individual's 'capability set'. RESULTS: Group differences and relationships with work and health outcomes were examined. Despite lower physical work functioning (U = 4250, p = 0.001), lower work ability (U = 10591, p = 0.006) and worse self-reported health (U = 9091, p ≤ 0.001) workers with MS had a larger capability set (U = 9649, p ≤ 0.001) than the general population. In workers with MS, a larger capability set was associated with better flexible work functioning (r = 0.30), work ability (r = 0.25), self-rated health (r = 0.25); and with less absenteeism (r = - 0.26), presenteeism (r = - 0.31), cognitive/neuropsychiatric impairment (r = - 0.35), depression (r = - 0.43), anxiety (r = - 0.31) and fatigue (r = - 0.34). CONCLUSIONS: Workers with MS have a larger capability set than workers from the general population. In workers with MS a larger capability set was associated with better work and health outcomes. TRIAL REGISTRATION: This observational study is registered under NL43098.008.12: 'Voorspellers van arbeidsparticipatie bij mensen met relapsing-remitting Multiple Sclerose'. The study is registered at the Dutch CCMO register ( https://www.toetsingonline.nl ). This study is approved by the METC Brabant, 12 February 2014. First participants are enrolled 1st of March 2014

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Full text link
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5<η<2.21.5 < \mid\eta\mid < 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 μ\murad pitch arranged in eight η\eta-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO2_{2} 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 μ\murad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ±\pm 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 ±\pm 1.6 (stat)] μ\murad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by \sim 10 μ\murad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ±\pm 2.5 stat] μ\murad is measured, consistent with the expected resolution of strip-pitch/12\sqrt{12} = 131.3 μ\murad. Other η\eta-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference adde

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector

    Get PDF
    In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown. © CERN 2016

    Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC

    Get PDF
    Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised

    Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    Get PDF
    In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS
    corecore