19 research outputs found

    Enhancing Prostate Cancer Detection Accuracy in Magnetic Resonance Imaging–targeted Prostate Biopsy:Optimizing the Number of Cores Taken

    Get PDF
    Background and objective: The shift toward targeted biopsy (TBx) aims at enhancing prostate cancer (PCa) detection while reducing overdiagnosis of clinically insignificant disease. Despite the improved ability of TBx in identifying clinically significant PCa (csPCa), the optimal number and location of targeted cores remain unclear. This review aims to assess the optimal number of prostate biopsy magnetic resonance imaging (MRI)-targeted cores to detect csPCa. Methods: A narrative literature search was conducted using PubMed, focusing on studies published between January 2014 and January 2024, addressing factors influencing targeted core numbers during prostate biopsy. The search included both retrospective and prospective studies, prioritizing those with substantial sample sizes and employing terms such as “prostate biopsy”, “mpMRI”, “core number”, and “cancer detection”. Key findings and limitations: Two biopsy cores identified csPCa in 55–65% of cases. This detection rate improved to approximately 90% when the number of cores was ≥5. The inclusion of perilesional and systematic biopsies could maximize the detection of csPCa (from 10% to 45%), especially in patients under active surveillance or with prior negative biopsy results, although there is an increase in the overdiagnosis of indolent tumors (from 4% to 20%). Transperineal software-assisted target prostate biopsy may enhance cancer detection, particularly for tumors located at the apex/anterior part of the prostate. Increasing the number of TBx cores may incrementally raise the risk of complications (by 2–14% with each added core) and result in severe pain and significant discomfort for up to 17% and 25% of TBx patients, respectively. However, the overall rate and severity of these complications remain within acceptable limits. Conclusions and clinical implications: The optimal number of cores for targeted prostate biopsies should balance minimizing sampling errors with effective cancer detection and should be tailored to each patient's unique prostate characteristics. Up to five cores per MRI target may be considered to enhance the detection of csPCa, with adjustments based on factors such as prostate and lesion volume, Prostate Imaging Reporting and Data System, biopsy techniques, complications, patient discomfort, and anxiety. Patient summary: In this report, we found that increasing the number of biopsy cores up to ≥5 improves the detection rates of significant prostate cancer significantly to around 90%. Although inclusion of nearby and systematic biopsies enhances detection, increasing the biopsy count may lead to higher risks of complications and indolent tumors. A customized biopsy approach based on multiple variables could be helpful in determining the appropriate number of targeted biopsies on a case-by-case basis.</p

    Enhancing Prostate Cancer Detection Accuracy in Magnetic Resonance Imaging–targeted Prostate Biopsy:Optimizing the Number of Cores Taken

    Get PDF
    Background and objective: The shift toward targeted biopsy (TBx) aims at enhancing prostate cancer (PCa) detection while reducing overdiagnosis of clinically insignificant disease. Despite the improved ability of TBx in identifying clinically significant PCa (csPCa), the optimal number and location of targeted cores remain unclear. This review aims to assess the optimal number of prostate biopsy magnetic resonance imaging (MRI)-targeted cores to detect csPCa. Methods: A narrative literature search was conducted using PubMed, focusing on studies published between January 2014 and January 2024, addressing factors influencing targeted core numbers during prostate biopsy. The search included both retrospective and prospective studies, prioritizing those with substantial sample sizes and employing terms such as “prostate biopsy”, “mpMRI”, “core number”, and “cancer detection”. Key findings and limitations: Two biopsy cores identified csPCa in 55–65% of cases. This detection rate improved to approximately 90% when the number of cores was ≥5. The inclusion of perilesional and systematic biopsies could maximize the detection of csPCa (from 10% to 45%), especially in patients under active surveillance or with prior negative biopsy results, although there is an increase in the overdiagnosis of indolent tumors (from 4% to 20%). Transperineal software-assisted target prostate biopsy may enhance cancer detection, particularly for tumors located at the apex/anterior part of the prostate. Increasing the number of TBx cores may incrementally raise the risk of complications (by 2–14% with each added core) and result in severe pain and significant discomfort for up to 17% and 25% of TBx patients, respectively. However, the overall rate and severity of these complications remain within acceptable limits. Conclusions and clinical implications: The optimal number of cores for targeted prostate biopsies should balance minimizing sampling errors with effective cancer detection and should be tailored to each patient's unique prostate characteristics. Up to five cores per MRI target may be considered to enhance the detection of csPCa, with adjustments based on factors such as prostate and lesion volume, Prostate Imaging Reporting and Data System, biopsy techniques, complications, patient discomfort, and anxiety. Patient summary: In this report, we found that increasing the number of biopsy cores up to ≥5 improves the detection rates of significant prostate cancer significantly to around 90%. Although inclusion of nearby and systematic biopsies enhances detection, increasing the biopsy count may lead to higher risks of complications and indolent tumors. A customized biopsy approach based on multiple variables could be helpful in determining the appropriate number of targeted biopsies on a case-by-case basis.</p

    Enhancing Prostate Cancer Detection Accuracy in Magnetic Resonance Imaging–targeted Prostate Biopsy: Optimizing the Number of Cores Taken

    Get PDF
    Background and objective: The shift toward targeted biopsy (TBx) aims at enhancing prostate cancer (PCa) detection while reducing overdiagnosis of clinically insignificant disease. Despite the improved ability of TBx in identifying clinically significant PCa (csPCa), the optimal number and location of targeted cores remain unclear. This review aims to assess the optimal number of prostate biopsy magnetic resonance imaging (MRI)-targeted cores to detect csPCa. Methods: A narrative literature search was conducted using PubMed, focusing on studies published between January 2014 and January 2024, addressing factors influencing targeted core numbers during prostate biopsy. The search included both retrospective and prospective studies, prioritizing those with substantial sample sizes and employing terms such as “prostate biopsy”, “mpMRI”, “core number”, and “cancer detection”. Key findings and limitations: Two biopsy cores identified csPCa in 55–65% of cases. This detection rate improved to approximately 90% when the number of cores was ≥5. The inclusion of perilesional and systematic biopsies could maximize the detection of csPCa (from 10% to 45%), especially in patients under active surveillance or with prior negative biopsy results, although there is an increase in the overdiagnosis of indolent tumors (from 4% to 20%). Transperineal software-assisted target prostate biopsy may enhance cancer detection, particularly for tumors located at the apex/anterior part of the prostate. Increasing the number of TBx cores may incrementally raise the risk of complications (by 2–14% with each added core) and result in severe pain and significant discomfort for up to 17% and 25% of TBx patients, respectively. However, the overall rate and severity of these complications remain within acceptable limits. Conclusions and clinical implications: The optimal number of cores for targeted prostate biopsies should balance minimizing sampling errors with effective cancer detection and should be tailored to each patient's unique prostate characteristics. Up to five cores per MRI target may be considered to enhance the detection of csPCa, with adjustments based on factors such as prostate and lesion volume, Prostate Imaging Reporting and Data System, biopsy techniques, complications, patient discomfort, and anxiety. Patient summary: In this report, we found that increasing the number of biopsy cores up to ≥5 improves the detection rates of significant prostate cancer significantly to around 90%. Although inclusion of nearby and systematic biopsies enhances detection, increasing the biopsy count may lead to higher risks of complications and indolent tumors. A customized biopsy approach based on multiple variables could be helpful in determining the appropriate number of targeted biopsies on a case-by-case basis

    The long-term risks of metastases in men on active surveillance for early stage prostate cancer

    No full text
    Purpose: We assessd the long-term outcomes from a large prospective cohort of men diagnosed with prostate cancer managed with active surveillance and determined the clinical prognostic factors that may predict the risk of metastases. Materials and methods: We retrospectively reviewed data of men enrolled on active surveillance at our institution between 1990 and 2018 with low or intermediate risk disease (stage cT1-2, prostate specific antigen less than 20 ng/ml, and biopsy Grade Group [GG]1-2). Patients were classified into 3 groups by diagnostic GG and prostate specific antigen density. Primary outcome was metastatic prostate cancer detected on imaging or at prostatectomy. In addition, upgrade at surveillance biopsy, active treatment, and overall and prostate cancer specific survival outcomes were assessed. Cox proportional hazards regression models were used. Results: A total of 1,450 men met the inclusion criteria. Median followup was 77 months (IQR 49-114). The 7-year metastasis-free survival rate was 99%. Metastases developed in 15 men at a median of 62 months (IQR 29-104), of which 69% were confined to lymph nodes. Men with GG2 had a lower metastasis-free survival rate compared to those with GG1 disease. GG2, prostate specific antigen velocity and PI-RADS® 4-5 lesions on multiparametric magnetic resonance imaging were associated with a higher risk of metastases. The 7-year prostate cancer specific survival was greater than 99%. Conclusions: Active surveillance seems to preserve favorable long-term prognosis, as metastases and prostate cancer specific death are rare. However, the higher risk of metastases associated with higher Gleason grade, prostate specific antigen velocity, and characteristics on multiparametric magnetic resonance imaging should be considered when selecting and counseling patients for active surveillance

    Characteristics of Cancer Progression on Serial Biopsy in Men on Active Surveillance for Early-stage Prostate Cancer: Implications for Focal Therapy

    No full text
    Active surveillance (AS) is a safe and accepted option for managing men with low-risk prostate cancer. Nevertheless, some patients lack confidence in or access to AS. Focal therapy (FT) is a possible alternative to radical treatment for such patients

    Dataset related to article "Xpert Bladder Cancer Monitor May Avoid Cystoscopies in Patients Under "Active Surveillance" for Recurrent Bladder Cancer (BIAS Project): Longitudinal Cohort Study "

    No full text
    This record contains raw data related to article “Xpert Bladder Cancer Monitor May Avoid Cystoscopies in Patients Under "Active Surveillance" for Recurrent Bladder Cancer (BIAS Project): Longitudinal Cohort Study" Abstract Objectives: To test the hypothesis that patients under active surveillance (AS) for Non-muscle Invasive Bladder Cancer (NMIBC) who were negative on longitudinal re-testing by the Xpert® Bladder Cancer Monitor (Xpert BC Monitor) assay may avoid unnecessary cystoscopies and urine cytology (UC). Subjects/patients or materials and methods: This is a prospective cohort study of patients enrolled in the AS protocol for recurrent NMIBC (Bladder Cancer Italian Active Surveillance, BIAS project), whose urine samples were analyzed by Xpert BC Monitor upon entry in the study (T0). Patients who had a negative Xpert test and did not fail AS, underwent additional Xpert tests after 4 (T1), 8 (T2), and 12 (T3) months. The clinical utility of Xpert was assessed by determining the number of cystoscopies and UC that could be avoided within 1 year. Results: Overall, 139 patients were tested with Xpert at T0. Median follow-up was 23 (IQR 17-27) months. Sixty-eight (48.9%) patients failed AS, 65 (46.7%) are currently on AS, and 6 (4.3%) were lost at follow-up. At T0 57 (41.0%) patients had a negative test and 36 (63.2%) are still in AS. In patients with 2 consecutives negative Xpert tests, we could have avoided 73.9% of unnecessary cystoscopies, missing 26.4% failure, up to avoid all cystoscopies with 4 negative tests missing only 12% of failure. All the patients with negative Xpert had negative UC. Failure-free-survival at median follow-up (23 month) stratified for having 0, 1, or ≥2 negative tests was 67.0, 55.1. and 84.1, respectively. Conclusion: Our findings suggest that Xpert BC Monitor assay, when it is longitudinally repeated, could significantly reduce the number of unnecessary cystoscopies and UC during their follow-up

    A systematic review and meta-analysis of randomized controlled trials with novel hormonal therapies for non-metastatic castration-resistant prostate cancer: an update from mature overall survival data

    No full text
    To get better insight into the management of non-metastatic castration-resistant prostate cancer (M0 CRPC), in this meta-analysis and review we aimed to present an updated evaluation of the efficacy and safety of novel hormonal therapies (nHT) for M0 CRPC according to final analyses with mature overall survival (OS) and safety data

    Dataset related to article "Prospective Validation of the ROL System in Substaging pT1 High-Grade Urothelial Carcinoma: Results from a Mono-Institutional Confirmatory Analysis in BCG Treated Patients"

    No full text
    &lt;p&gt;This record contains raw data related to article "Prospective Validation of the ROL System in Substaging pT1 High-Grade Urothelial Carcinoma: Results from a Mono-Institutional Confirmatory Analysis in BCG Treated Patients"&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Abstract&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Patients with pT1 high-grade (HG) urothelial carcinoma (UC) and a very high risk of progression might benefit from immediate radical cystectomy (RC), but this option remains controversial. Validation of a standardized method to evaluate the extent of lamina propria (LP) invasion (with recognized prognostic value) in transurethral resection (TURBT) specimens is still needed. The Rete Oncologica Lombarda (ROL) system showed a high predictive value for progression after TURBT in recent retrospective studies. The ROL system was supposed to be validated on a large prospective series of primary urothelial carcinomas from a single institution. From 2016 to 2020, we adopted ROL for all patients with pT1 HG UC on TURBT. We employed a 1.0-mm threshold to stratify tumors in ROL1 and ROL2. A total of 222 pT1 HG UC were analyzed. The median age was 74 years, with a predominance of men (73.8%). ROL was feasible in all cases: 91 cases were ROL1 (41%), and 131 were ROL2 (59%). At a median follow-up of 26.9 months (IQR 13.8-40.6), we registered 81 recurrences and 40 progressions. ROL was a significant predictor of tumor progression in both univariable (HR 3.53; CI 95% 1.56-7.99; &lt;i&gt;p&lt;/i&gt; &lt; 0.01) and multivariable (HR 2.88; CI 95% 1.24-6.66; &lt;i&gt;p&lt;/i&gt; = 0.01) Cox regression analyses. At Kaplan-Meier estimates, ROL showed a correlation with both PFS (&lt;i&gt;p&lt;/i&gt; = 0.0012) and RFS (&lt;i&gt;p&lt;/i&gt; = 0.0167). Our results confirmed the strong predictive value of ROL for progression in a large prospective series. We encourage the application of ROL for reporting the extent of LP invasion, substaging T1 HG UC, and improving risk tables for urological decision-making.&lt;/p&gt

    Prospective Validation of the ROL System in Substaging pT1 High-Grade Urothelial Carcinoma: Results from a Mono-Institutional Confirmatory Analysis in BCG Treated Patients

    No full text
    Patients with pT1 high-grade (HG) urothelial carcinoma (UC) and a very high risk of progression might benefit from immediate radical cystectomy (RC), but this option remains controversial. Validation of a standardized method to evaluate the extent of lamina propria (LP) invasion (with recognized prognostic value) in transurethral resection (TURBT) specimens is still needed. The Rete Oncologica Lombarda (ROL) system showed a high predictive value for progression after TURBT in recent retrospective studies. The ROL system was supposed to be validated on a large prospective series of primary urothelial carcinomas from a single institution. From 2016 to 2020, we adopted ROL for all patients with pT1 HG UC on TURBT. We employed a 1.0-mm threshold to stratify tumors in ROL1 and ROL2. A total of 222 pT1 HG UC were analyzed. The median age was 74 years, with a predominance of men (73.8%). ROL was feasible in all cases: 91 cases were ROL1 (41%), and 131 were ROL2 (59%). At a median follow-up of 26.9 months (IQR 13.8–40.6), we registered 81 recurrences and 40 progressions. ROL was a significant predictor of tumor progression in both univariable (HR 3.53; CI 95% 1.56–7.99; p p = 0.01) Cox regression analyses. At Kaplan-Meier estimates, ROL showed a correlation with both PFS (p = 0.0012) and RFS (p = 0.0167). Our results confirmed the strong predictive value of ROL for progression in a large prospective series. We encourage the application of ROL for reporting the extent of LP invasion, substaging T1 HG UC, and improving risk tables for urological decision-making
    corecore