1,458 research outputs found

    The Bouncing Jet: A Newtonian Liquid Rebounding off a Free Surface

    Get PDF
    We find that a liquid jet can bounce off a bath of the same liquid if the bath is moving horizontally with respect to the jet. Previous observations of jets rebounding off a bath (e.g. Kaye effect) have been reported only for non-Newtonian fluids, while we observe bouncing jets in a variety of Newtonian fluids, including mineral oil poured by hand. A thin layer of air separates the bouncing jet from the bath, and the relative motion replenishes the film of air. Jets with one or two bounces are stable for a range of viscosity, jet flow rate and velocity, and bath velocity. The bouncing phenomenon exhibits hysteresis and multiple steady states.Comment: 9 pages, 7 figures. submitted to Physical Review

    On the Influence of low-power laser source on the evaporation of single droplets: experimental and numerical approaches

    Get PDF
    This work investigates the influence of laser power on an evaporating single droplet made from an H2O and NaCl mixture. Heat and mass transfer of a single droplet with the presence of a low-power laser source (as He-Ne laser) is studied both numerically and experimentally in this article. A new model is presented to simulate water droplet evaporation. The model is robust enough to be applied for various initial concentrations and conditions of the droplet, ambient conditions, and dissolved media properties. Moreover, laser energy is taken into consideration as a source term which is a function of the wave length of the source beam and refractive index of the droplet. Considering the involved parameters, the model is implemented in a MATLAB code and validated using experimental data obtained in this study on top of those already available in the literature. Experimental data were collected for droplets with an initial radius of 500ÎĽm at room temperature for three initial concentrations of 3%, 5%, and 10% (by mass) of NaCl in water as well as pure water droplet to provide a comprehensive validation dataset. It is shown that low-power laser source significantly increases the evaporation rate (2.7 to 5.64 for 0% and 10% initial concentration of salt, respectively) which must be taken into consideration while using laser based measurement techniques

    Virtual Art Therapy. Application of Michelangelo Effect to Neurorehabilitation of Patients with Stroke

    Get PDF
    In neurorehabilitation, some studies reported the effective use of art therapy for reducing psychological disorders and for enhancing physical functions and cognitive abilities. Neuroaesthetical studies showed that seeing an art masterpiece can spontaneously elicit a widespread brain arousal, also involving motor networks. To combine contemplative and performative benefits of art therapy protocols, we have developed an immersive virtual reality system, giving subjects the illusion that they are able to paint a copy of famous artistic paintings. We previously observed that during this virtual task, subjects perceived less fatigue and performed more accurate movements than when they were asked to color the virtual canvas. We named this upshot the Michelangelo effect. The aim of this study was to test the rehabilitative efficacy of our system. Ten patients with stroke in the subacute phase were enrolled and trained for one month with virtual art therapy (VAT) and physiotherapy. Their data were compared with those of ten patients matched for pathology, age and clinical parameters, trained only with conventional therapy for the same amount of time. The VAT group showed a significantly higher improvements in the Barthel Index score, a measure of independency in activities of daily living (66 ± 33% vs. 31 ± 28%, p = 0.021), and in pinching strength (66 ± 39% vs. 18 ± 33%, p = 0.008), with respect to the group treated with conventional rehabilitation

    Effect of pre-season training phase on anthropometric, hormonal and fitness parameters in young soccer players

    Get PDF
    The aims of the study were to investigate 1) the effect of 8 weeks of PSP training on anthropometrics, salivary hormones and fitness parameters in youth soccer players, 2) the correlations between fitness and hormonal parameters, and 3) the impact of the experience of the coach and his methodology of training on these parameters. Weight, height, BMI, pubertal development (PDS), salivary Cortisol (sC), salivary Testosterone (sT), salivary sDHEAS, intermittent tests (VO2max), and countermovement jump test (CMJ) modifications of 35 youth soccer players (age: 14±0 yrs; BMI: 20.8±1.8 k/m2 ) from two Italian clubs (“Lupa Frascati” -LF-; “Albalonga” -AL) were analysed. A significant (p<0.05) time by club effect was observed in sC (F(1,31) = 9.7, ES = 1.13), sT (F(1,31) = 4.2, ES = 0.74), CMJ (F(1,28) = 26.5, ES = 1.94), and VO2max (F(1,28) = 8.5, ES = 1.10). Statistical differences (p<0.05) in weight (F(1,32) = 25.5, ES = 0.11), sC (F(1,31) = 32.1, ES = 1.43), sT/sC ratio (F(1,31) = 10.1, ES = 0.97), sDHEAS/sC ratio (F(1,31) = 6.3, ES = 0.70), and VO2max (F(1,28) = 64.3, ES = 1.74) were found within time factor. Between clubs, differences (p<0.05) in sC (F(1,32) = 8.5, ES = 1.17), sT (F(1,31) = 4.2, ES = 0.74), CMJ (F(1,28) = 26.5, ES = 1.50), and VO2max (F(1,28) = 8.5, ES = 1.10) were found. CMJ was inversely correlated with sDHEAS (r = -0.38) before PSP, while Δ of CMJ showed significant correlations with Δ of sC (r = 0.43) and ΔVO2max was inversely correlated with ΔBMI (r = -0.54) and ΔsC (r = -0.37) in all subjects. Considering each single club, ΔVO2max showed correlations with ΔBMI (r = -0.45) in AL, while ΔCMJ showed correlations with ΔPDS (r = 0.72) in LF club. Since the PSP is often limited training time to simultaneously develop physical, technical and tactical qualities, an efficient method to distribute the training load is important in youth soccer players to increase the performance and to avoid injuries

    Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection

    Get PDF
    In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called 'superattenuator', is fully effective at frequencies above 4 Hz. Nevertheless, the residual motion of the mirror at the mechanical resonant frequencies of the system are too large for the interferometer locking system and must be damped. A multidimensional feedback system, using inertial sensors and digital processing, has been designed for this purpose. An experimental procedure for determining the feedback control of the system has been defined. In this paper a full description of the system is given and experimental results are presented.Comment: 17 pages, 11 figures, accepted for publication on Review of Scientific Instrument

    Testing the performance of a blind burst statistic

    Full text link
    In this work we estimate the performance of a method for the detection of burst events in the data produced by interferometric gravitational wave detectors. We compute the receiver operating characteristics in the specific case of a simulated noise having the spectral density expected for Virgo, using test signals taken from a library of possible waveforms emitted during the collapse of the core of Type II Supernovae.Comment: 8 pages, 6 figures, Talk given at the GWDAW2002 worksho

    Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium

    Get PDF
    The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system identical to that one used in the VIRGO experiment. The measured relative displacement power spectrum is compatible with a system at thermal equilibrium within its environmental. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the measurement distribution is stationary and Gaussian, as expected for a system at thermal equilibrium. Through a simple mechanical model it is shown that: applying the fluctuation dissipation theorem the measured power spectrum is reproduced below 90 Hz and noise induced by external sources are below the measurement.Comment: 11 pages, 9 figures, 2 tables, to be submitte

    Is it possible to detect gravitational waves with atom interferometers?

    Get PDF
    We investigate the possibility to use atom interferometers to detect gravitational waves. We discuss the interaction of gravitational waves with an atom interferometer and analyze possible schemes

    On line power spectra identification and whitening for the noise in interferometric gravitational wave detectors

    Get PDF
    In this paper we address both to the problem of identifying the noise Power Spectral Density of interferometric detectors by parametric techniques and to the problem of the whitening procedure of the sequence of data. We will concentrate the study on a Power Spectral Density like the one of the Italian-French detector VIRGO and we show that with a reasonable finite number of parameters we succeed in modeling a spectrum like the theoretical one of VIRGO, reproducing all its features. We propose also the use of adaptive techniques to identify and to whiten on line the data of interferometric detectors. We analyze the behavior of the adaptive techniques in the field of stochastic gradient and in the Least Squares ones.Comment: 28 pages, 21 figures, uses iopart.cls accepted for pubblication on Classical and Quantum Gravit

    Current hepatocellular carcinoma systemic pharmacological treatment options

    Get PDF
    Liver cancer is the sixth common cancer and the second leading cause of cancer death worldwide. Hepatocellular carcinoma (HCC) accounts for ~90% of cases of liver cancer and is the fourth most common cause of cancer-related death in the world. Up to now, 4 oral multityrosine kinase inhibitors (sorafenib, lenvatinib, regorafenib and cabozantinib), 1 anti-angiogenic antibody (ramucirumab) and 5 immune checkpoint inhibitors, alone or in combination (atezolizumab in combination with bevacizumab, ipilimumab in combination with nivolumab, tremelimumab in combination with durvalumab, nivolumab and pembrolizumab in monotherapy) have been commercialized for advanced HCC patients’ treatment. The aim of this editorial is to provide an insight in current hepatocellular carcinoma systemic pharmacological treatment options
    • …
    corecore