507 research outputs found

    Radiation induced currents in mineral-insulated cables and in pick-up coils: model calculations and experimental verification in the BR1 reactor

    Get PDF
    Mineral-insulated (MI) cables and Low-Temperature Co-fired Ceramic (LTCC) magnetic pick-up coils are intended to be installed in various position in ITER. The severe ITER nuclear radiation field is expected to lead to induced currents that could perturb diagnostic measurements. In order to assess this problem and to find mitigation strategies models were developed for the calculation of neutron-and gamma-induced currents in MI cables and in LTCC coils. The models are based on calculations with the MCNPX code, combined with a dedicated model for the drift of electrons stopped in the insulator. The gamma induced currents can be easily calculated with a single coupled photon-electron MCNPX calculation. The prompt neutron induced currents requires only a single coupled neutron-photon-electron MCNPX run. The various delayed neutron contributions require a careful analysis of all possibly relevant neutron-induced reaction paths and a combination of different types of MCNPX calculations. The models were applied for a specific twin-core copper MI cable, for one quad-core copper cable and for silver conductor LTCC coils (one with silver ground plates in order to reduce the currents and one without such silver ground plates). Calculations were performed for irradiation conditions (neutron and gamma spectra and fluxes) in relevant positions in ITER and in the Y3 irradiation channel of the BR1 reactor at SCK•CEN, in which an irradiation test of these four test devices was carried out afterwards. We will present the basic elements of the models and show the results of all relevant partial currents (gamma and neutron induced, prompt and various delayed currents) in BR1-Y3 conditions. Experimental data will be shown and analysed in terms of the respective contributions. The tests were performed at reactor powers of 350 kW and 1 MW, leading to thermal neutron fluxes of 1E11 n/cm2s and 3E11 n/cm2s, respectively. The corresponding total radiation induced currents are ranging from 1 to 7 nA only, putting a challenge on the acquisition system and on the data analysis. The detailed experimental results will be compared with the corresponding values predicted by the model. The overall agreement between the experimental data and the model predictions is fairly good, with very consistent data for the main delayed current components, while the lower amplitude delayed currents and some of the prompt contributions show some minor discrepancies

    Creating room for citizen perspectives in ‘smart city’ Amsterdam through interactive theatre

    Get PDF
    The ‘smart city’ vision is popular, but it lacks citizen perspectives. The aim of this study was to gain insight into whether and how art-based citizen engagement can create more room for citizen perspectives in smart cities by developing and testing an art-based citizen engagement project in Amsterdam, the Netherlands. To that end, a combination of interactive theatre, interaction design and social research methods was used to bring together diverse publics and innovation professionals for joint exploration of increased dataveillance in cities. The events were studied through observations, and through interviews with participants and organisers. Data analysis was guided by the outcomes, processes and challenges of the responsible innovation dimensions: inclusion, reflexivity, anticipation and responsiveness (Stilgoe et al., 2013). The most important achievements of art-based citizen engagement were: engaging people who would not have engaged with the topic otherwise, encouraging participants to question common phrases and assumptions, exploring future social implications of technologies, and staging meaningful interactions between citizens and professionals. The most significant challenge was to involve citizens in a way that could influence innovation trajectories

    Optical polarization of neutron-rich sodium isotopes and β\beta-NMR measurements of quadrupole moments

    Get PDF
    The nuclear quadrupole moments of neutron-rich sodium isotopes are being investigated with the help of in-beam polarization by optical pumping in combination with β\beta-NMR techniques. First measurements have yielded the quadrupole splittings of NMR signals in the lattice of LiNbO3_{3} for the isotopes 26^{26}Na, 27^{27}Na and 28^{28}Na. Interaction constants and ratios of the electric quadrupole moments are derived. In view of future experiments, β\beta-decay asymmetries for the sequence of isotopes up to the NN=20 neutron shell closure, 2631^{26-31}Na, have been measured

    Feasibility of Sentinel Node Biopsy in Head and Neck Melanoma Using a Hybrid Radioactive and Fluorescent Tracer

    Get PDF
    This study was designed to examine the feasibility of combining lymphoscintigraphy and intraoperative sentinel node identification in patients with head and neck melanoma by using a hybrid protein colloid that is both radioactive and fluorescent. Eleven patients scheduled for sentinel node biopsy in the head and neck region were studied. Approximately 5 h before surgery, the hybrid nanocolloid labeled with indocyanine green (ICG) and technetium-99m ((99m)Tc) was injected intradermally in four deposits around the scar of the primary melanoma excision. Subsequent lymphoscintigraphy and single photon emission computed tomography with computed tomography (SPECT/CT) were performed to identify the sentinel nodes preoperatively. In the operating room, patent blue dye was injected in 7 of the 11 patients. Intraoperatively, sentinel nodes were acoustically localized with a gamma ray detection probe and visualized by using patent blue dye and/or fluorescence-based tracing with a dedicated near-infrared light camera. A portable gamma camera was used before and after sentinel node excision to confirm excision of all sentinel nodes. A total of 27 sentinel nodes were preoperatively identified on the lymphoscintigraphy and SPECT/CT images. All sentinel nodes could be localized intraoperatively. In the seven patients in whom blue dye was used, 43% of the sentinel nodes stained blue, whereas all were fluorescent. The portable gamma camera identified additional sentinel nodes in two patients. Ex vivo, all radioactive lymph nodes were fluorescent and vice versa, indicating the stability of the hybrid tracer. ICG-(99m)Tc-nanocolloid allows for preoperative sentinel node visualization and concomitant intraoperative radio- and fluorescence guidance to the same sentinel nodes in head and neck melanoma patient

    Moments and mean square charge radii of short-lived argon isotopes

    Get PDF
    We report on the measurement of optical isotope shifts for 3240^{32-40}Ar and for 46^{46}Ar from which the changes in mean square nuclear charge radii across the N = 20 neutron shell closure are deducted. The investigations were carried out by collinear laser spectroscopy in fast beams of neutral argon atoms. The ultra-sensitive detection combines optical pumping, state-selective collisional ionization and counting of β\beta-radioactivity. By reaching far into the sd-shell, the results add new information to the systematics of radii in the calcium region (Z \approx 20). Contrary to all major neutron shell closures with N \geq 28, the N = 20 shell closure causes no significant slope change in the development of the radii. Information from the hyperfine structure of the odd-A isotopes includes includes the magnetic moments of 33^{33}Ar (I=1/2) and 39^{39}Ar (I=7/2), and the quadrupole moments of 35^{35}Ar, 37^{37}Ar (I=3/2) and 39^{39}Ar. The electromagnetic moments are compared to shell-model predictions for the sd- and fp-shell. Even far from stability a very good agreement between experiment and theory is found for these quantities. The mean square charge radii are discussed in the framework of spherical SGII Skyrme-type Hartree-Fock calculations

    Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    Get PDF
    Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described

    Lagrangian multiforms on Lie groups and non-commuting flows

    Get PDF
    We describe a variational framework for non-commuting flows, extending the theories of Lagrangian multiforms and pluri-Lagrangian systems, which have gained prominence in recent years as a variational description of integrable systems in the sense of multidimensional consistency. In the context of non-commuting flows, the manifold of independent variables, often called multi-time, is a Lie group whose bracket structure corresponds to the commutation relations between the vector fields generating the flows. Natural examples are provided by superintegrable systems for the case of Lagrangian 1-form structures, and integrable hierarchies on loop groups in the case of Lagrangian 2-forms. As particular examples we discuss the Kepler problem, the rational Calogero-Moser system, and a generalisation of the Ablowitz-Kaup-Newell-Segur system with non-commuting flows. We view this endeavour as a first step towards a purely variational approach to Lie group actions on manifolds

    On the odd-even staggering of mean square charge radii in the light krypton and strontium region

    Get PDF
    Recently isotope shifts of 72,7496^{72,74-96}Kr and 77100^{77-100}Sr have been measured at the ISOLDE/ CERN mass separator facility by collinear laser spectroscopy. The deduced changes in mean square charge radii reveal sharp transitions in nuclear shape from spherical near the magic neutron number N=50 towards strongly deformed for both the neutron deficient and neutron rich isotopes far from stability. The mean square charge radii of the neutron deficient isotopes exhibit a sign change of the odd-even staggering (OES), i.e. below the neutron number N=46 the radius is systematically larger for the odd-N nuclei than for their even-N neighbours. This is in contrast to the situation of normal OES which is observed for the heavier isotopes. The inversion of the OES is interpreted as an effect of polarization, triggered by the addition of an unpaired neutron and driving the soft even-even core into stable strong deformation
    corecore