58 research outputs found
Ramp Type HTS Josephson Junctions with PrBaCuGaO Barriers
Ramp type Josephson junctions have been fabricated using DyBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// as electrode material and PrBa/sub 2/Cu/sub 3-x/Ga/sub x/O/sub 7-/spl delta// with x=0, 0.10 and 0.40 as junction barriers. Barrier thickness lie between 6-30 nm. Several junctions without barrier were made in order to find ways to minimize the damage of the ramp interface. In total about 40 chips were fabricated each containing several junctions and their I-V characteristics measured for various temperatures down to 4.2 K. Only those junctions showing clear RSJ-like curves were selected to be analyzed. In some cases we also measured I/sub c/ as a function of a small applied field and obtained a clear Fraunhofer pattern, but there is a tendency to flux trapping as evidenced by LTSEM. It was found at 4.2 K that the critical current density J/sub c/ scales with the specific resistance R/sub n/A as J/sub c/=C/sub bar/(R/sub n/A)/sup -m/ (m=1.8/spl plusmn/0.5). The barrier material dependent constant C/sub bar/ increases with x, whereas, for a given d, J/sub c/ is constant and R/sub n/A increase
A high-Tc 4-bit periodic threshold analog-to-digital converter
Using ramp-type Josephson junctions a 4-bit periodic threshold ADC has been designed, fabricated and tested. Practical design constraints will be discussed in terms of noise immunity, flux flow, available technology, switching speed etc. In a period of four years we fabricated about 100 chips in order to bring the technology to an acceptable level and to test various designs and circuit layouts. This resulted in a basic comparator that is rather insensitive to the stray field generated by the analog input signal or variations in mask alignment during fabrication. The input signal is fed into the comparators using a resistive divider network. Full functionality at low frequencies has been demonstrate
An HTS Quasi-One junction SQUID-based periodic threshold comparator for a 4-bit superconductive flash A/D converter
An all high-Tc periodic threshold comparator for application in a 4-bit superconductive A/D converter has been realized and tested. The theoretical threshold curve of the comparator is calculated and compared to the measured results. Furthermore, the thermal noise immunity and the influence of flux-flow are considered, resulting in practical design constraints for the comparator circui
High-Tc ramp-type Josephson junctions on MgO substrates for Terahertz applications
The authors successfully fabricated high-Tc ramp-type junctions with PrBa2Cu3-xGaxO7-δ (PBCGO: x=0.1, 0.4) barriers on MgO substrates. The junctions showed resistively shunted Josephson junction (RSJ)-like I-V curves with thermally and voltage activated conductivity. The IcRn products for these junctions scaled very well with the Ga-doping. Maximum response of the junctions for 100-GHz millimeter-wave irradiation could be observed up to 12 mV corresponding to 6 THz. Using far infrared laser radiation, we confirmed a terahertz (THz) response of these junctions. These results show promise for THz-wave applications of ramp-type Josephson junctions
Characterization of ramp-type YBa<sub>2</sub>Cu<sub>3</sub>O<sub>7</sub> junctions by AFM
We studied the morphology of ramps in REBa2Cu3O7 (REBCO) epitaxial films on SrTiO3 substrates, fabricated by RF magnetron sputter deposition and pulsed laser deposition (PLD), by Atomic Force Microscopy (AFM) and High Resolution Electron Microscopy (HREM). The ramps were fabricated by Ar ion beam etching using different masks of standard photoresist and TiN. AFM-studies on ramps in sputter deposited films show a strong dependence, i.e., formation of facets and ridges, on the angle of incidence of the ion beam with respect to the substrate surface as well as the rotation angle with respect to the crystal axes of the substrate. Ramps in pulsed laser deposited films did not show this dependence. Furthermore, we studied the effect of an anneal step prior to the deposition of barrier layers (i.e. PrBa2Cu3-xGaxO7) on the ramp. First results show a crystallization of the ramp surface, resulting in terraces and a non-homogeneous growth of the barrier material on top of it. The thickness variations, for thin layers of barrier material, can even become much larger than expected from the amount of deposited material and are dependent on the deposition and anneal conditions. HREM studies show a well-defined interface between barrier layer and electrodes. The angle of the ramp depends on the etch rate of the mask and REBCO and on the angle of incidence of the ion beam. Hard masks, like TIN, have a much lower etch rate compared to photoresist, resulting in an angle of the ramp comparable to the angle of incidence and, subsequently, in a low etching rate on the ram
Recovery of dialysis patients with COVID-19 : health outcomes 3 months after diagnosis in ERACODA
Background. Coronavirus disease 2019 (COVID-19)-related short-term mortality is high in dialysis patients, but longer-term outcomes are largely unknown. We therefore assessed patient recovery in a large cohort of dialysis patients 3 months after their COVID-19 diagnosis. Methods. We analyzed data on dialysis patients diagnosed with COVID-19 from 1 February 2020 to 31 March 2021 from the European Renal Association COVID-19 Database (ERACODA). The outcomes studied were patient survival, residence and functional and mental health status (estimated by their treating physician) 3 months after COVID-19 diagnosis. Complete follow-up data were available for 854 surviving patients. Patient characteristics associated with recovery were analyzed using logistic regression. Results. In 2449 hemodialysis patients (mean ± SD age 67.5 ± 14.4 years, 62% male), survival probabilities at 3 months after COVID-19 diagnosis were 90% for nonhospitalized patients (n = 1087), 73% for patients admitted to the hospital but not to an intensive care unit (ICU) (n = 1165) and 40% for those admitted to an ICU (n = 197). Patient survival hardly decreased between 28 days and 3 months after COVID-19 diagnosis. At 3 months, 87% functioned at their pre-existent functional and 94% at their pre-existent mental level. Only few of the surviving patients were still admitted to the hospital (0.8-6.3%) or a nursing home (∼5%). A higher age and frailty score at presentation and ICU admission were associated with worse functional outcome. Conclusions. Mortality between 28 days and 3 months after COVID-19 diagnosis was low and the majority of patients who survived COVID-19 recovered to their pre-existent functional and mental health level at 3 months after diagnosis
On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection
A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
Genome-wide association meta-analysis of corneal curvature identifies novel loci and shared genetic influences across axial length and refractive error.
Corneal curvature, a highly heritable trait, is a key clinical endophenotype for myopia - a major cause of visual impairment and blindness in the world. Here we present a trans-ethnic meta-analysis of corneal curvature GWAS in 44,042 individuals of Caucasian and Asian with replication in 88,218 UK Biobank data. We identified 47 loci (of which 26 are novel), with population-specific signals as well as shared signals across ethnicities. Some identified variants showed precise scaling in corneal curvature and eye elongation (i.e. axial length) to maintain eyes in emmetropia (i.e. HDAC11/FBLN2 rs2630445, RBP3 rs11204213); others exhibited association with myopia with little pleiotropic effects on eye elongation. Implicated genes are involved in extracellular matrix organization, developmental process for body and eye, connective tissue cartilage and glycosylation protein activities. Our study provides insights into population-specific novel genes for corneal curvature, and their pleiotropic effect in regulating eye size or conferring susceptibility to myopia
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
- …