27 research outputs found

    Cathodic adsorptive stripping voltammetric determination of rutin in soybean cultivars

    Get PDF
    AbstractA highly sensitive and selective cathodic adsorptive stripping voltammetric method for determination of rutin is presented. The method relies on the accumulation of a Cu(II)–rutin complex at a hanging mercury drop electrode (HMDE), followed by its reduction during a differential pulse voltammetric scan. The electrochemical behavior of the Cu(II)–rutin complex at HMDE was investigated by cyclic voltammetry. Results show that the electrode process is adsorption-controlled and gradually becomes less reversible at high scan rates where peak separation grows. Under the optimized conditions (phosphate buffer pH 6, −1.000V accumulation potential, 180s accumulation time, 70mV pulse amplitude, 50mVs−1 scan rate and 1.6×10−6M Cu(II) concentration), the reduction peak current (Ipc) of the Cu(II)–rutin complex is linear (Ipc (nA)=10.070+1.9×108 [Rutina]) to rutin concentration in the range from 2.0×10−7 to 1.4×10−6M, with a correlation coefficient of 0.999. The detection and quantification limits obtained were 7.0×10−9M and 2.2×10−8M, respectively. The method was successfully applied to the determination of rutin in soybean cultivars, with recoveries of 94–105%

    Tomografia computadorizada aplicada a estudos de um Planossolo

    Get PDF
    In order to find better techniques to evaluate the soil physical parameters applied to lowland soils, the computerized tomography has been used to measure soil density and water content with accuracy and high spatial resolution. This work was carried out in order to describe features and calibration procedures of a computerized minitomographer using X-ray and gama-rays as sources of radiation and to establish suitable statistical parameters on the study of soil bulk density and water content in a Planosol (Albaqualf) from Rio Grande do Sul State, Brazil. The minitomographer calibration was obtained from the linear regression equation among the tomography's unities (TU) presented by the image reconstruction program and the linear attenuation coefficient (ml, cm-1), by the measurement of direct transmission of g-rays as source of radiation in soil samples from A and B horizons, distilled water, benzin and aluminum. In order to get measures of the direct radiation transmission, containers with distilled water, benzin, soil and aluminum were used to obtain the following equations to calculate soil bulk density in the A horizon: Ds = [(TU/986.16)-(0.200xq)]/0.267 and in the B horizon: Ds = [(TU/986.16)-(0.200xq)]/0.297, where TU is the mean value in the line and q is the soil volumetric water content (m3 m-3). The obtained configurations allowed to attain average variabilities of 2.74% and 0.73% for homogeneity and repeatability, respectively. The expected errors related to the equipment are 0.051 and 0.046 Mg m-3, to the A and B horizons, respectively. The results showed the technique accuracy and adaptability in the studies of the physical characteristics of a Planosol.Na busca de técnicas mais apuradas para a determinação e avaliação de parâmetros físicos do solo com aplicabilidade em várzeas, vem se destacando a tomografia computadorizada, por medir a densidade e a umidade com boa sensibilidade e alta resolução espacial. O presente trabalho teve como objetivo descrever aspectos e procedimentos da calibração de um minitomógrafo de raios-X e gama para estudo da densidade e umidade de um Planossolo no Rio Grande do Sul, bem como estabelecer parâmetros estatísticos para sua adequada utilização. A calibração do minitomógrafo foi obtida pela regressão linear entre as unidades tomográficas (UT), apresentadas pelo programa de reconstrução de imagem, e os coeficientes de atenuação linear (μ1, cm-1), medidos por transmissão direta de raios gama, em amostras dos horizontes A e B do Planossolo, água destilada, benzina e alumínio. Para as medidas de transmissão direta de radiação utilizaram-se recipientes com água destilada, benzina, solo e Al, obtendo-se as seguintes fórmulas para o cálculo da densidade do solo no horizonte A: Ds = [(UT/986,16)-(0,200xθ)]/0,267; e no horizonte B: Ds = [(UT/986,16)-(0,200xθ)]/0,297, em que UT é o valor médio de UT em cada linha e θé a umidade volumétrica da amostra de solo, em m3 m-3. Com as configurações obtidas, verificou-se variabilidade média de 2,74% e 0,73%, respectivamente, em termos de homogeneidade e repetibilidade. Os erros atribuídos ao equipamento são de 0,051 e 0,046 Mg m-3, respectivamente, nos horizontes A e B, revelando precisão e adaptabilidade no emprego da técnica em estudos do Planossolo

    Validation of the Arya and Paris Water Retention Model for Brazilian Soils

    Get PDF
    ABSTRACT type (porous plate funnel, tension table) and pressuretype cell apparatus (Richard chamber) with both undis- The Arya and Paris (AP) model predicts soil water retention curves turbed or disturbed soil core samples. from soil particle-size distribution (PSD) data based on the similarity Due to the relatively long time involved in the deterbetween these two functions. The AP model estimates pore radius mination of water retention curves, there is an increasing tion relationships

    Tamanho de amostras para a determinação de parâmetros físicos em planossolo por tomografia computadorizada

    Get PDF
    A técnica da tomografia computadorizada (TC) permite medir a densidade e a umidade de amostras de solo, constituindo uma importante ferramenta na Ciência do Solo. Este trabalho tem como objetivos descrever os aspectos da adequação do tamanho de amostras de um Planossolo e os procedimentos de avaliação e estudos por análise estatística, empregando-se um minitomógrafo computadorizado de raios gama com fonte de 241Am. O valor do erro atribuído ao equipamento são 0,051 e 0,046 Mg m-3, respectivamente, para os horizontes A e B. O valor teórico da espessura da amostra do Planossolo para uso na técnica de TC com fonte de 241Am é, aproximadamente, 4,0 cm para os horizontes A e B. Já a espessura ideal de amostras é de aproximadamente 6,0 cm, sendo menor para amostras do horizonte B em relação ao A. Obteve-se boa precisão e adaptabilidade no emprego da TC para estudos de Planossolos._________________________________________________________________________________ ABSTRACT: Computerized tomography (CT) is an important tool in Soil Science for noninvasive measurement of density and water content of soil samples. This work aims to describe the aspects of sample size adequacy for Planosol (Albaqualf) and to evaluate procedures for statistical analysis, using a CT scanner with a 241Am source. Density errors attributed to the equipment are 0.051 and 0.046 Mg m-3 for horizons A and B, respectively. The theoretical value for sample thickness for the Planosol, using this equipment, is 4.0 cm for the horizons A and B. The ideal thickness of samples is approximately 6.0 cm, being smaller for samples of the horizon B in relation to A. Alternatives for the improvement of the efficiency analysis and the reliability of the results obtained by CT are also discussed, and indicate good precision and adaptability of the application of this technology in Planosol (Albaqualf) studies

    Computer-assisted tomography for studies of an Albaqualf

    Get PDF
    Na busca de técnicas mais apuradas para a determinação e avaliação de parâmetros físicos do solo com aplicabilidade em várzeas, vem se destacando a tomografia computadorizada, por medir a densidade e a umidade com boa sensibilidade e alta resolução espacial. O presente trabalho teve como objetivo descrever aspectos e procedimentos da calibração de um minitomógrafo de raios-X e gama para estudo da densidade e umidade de um Planossolo no Rio Grande do Sul, bem como estabelecer parâmetros estatísticos para sua adequada utilização. A calibração do minitomógrafo foi obtida pela regressão linear entre as unidades tomográficas (UT), apresentadas pelo programa de reconstrução de imagem, e os coeficientes de atenuação linear (µl, cm-1), medidos por transmissão direta de raios gama, em amostras dos horizontes A e B do Planossolo, água destilada, benzina e alumínio. Para as medidas de transmissão direta de radiação utilizaram-se recipientes com água destilada, benzina, solo e Al, obtendo-se as seguintes fórmulas para o cálculo da densidade do solo no horizonte A: Ds = [(UT/986,16)-(0,200xq)]/0,267; e no horizonte B: Ds = [(UT/986,16)-(0,200xq)]/0,297, em que UT é o valor médio de UT em cada linha e q é a umidade volumétrica da amostra de solo, em m3 m-3. Com as configurações obtidas, verificou-se variabilidade média de 2,74% e 0,73%, respectivamente, em termos de homogeneidade e repetibilidade. Os erros atribuídos ao equipamento são de 0,051 e 0,046 Mg m-3, respectivamente, nos horizontes A e B, revelando precisão e adaptabilidade no emprego da técnica em estudos do Planossolo._________________________________________________________________________________ ABSTRACT: In order to find better techniques to evaluate the soil physical parameters applied to lowland soils, the computerized tomography has been used to measure soil density and water content with accuracy and high spatial resolution. This work was carried out in order to describe features and calibration procedures of a computerized minitomographer using X-ray and gama-rays as sources of radiation and to establish suitable statistical parameters on the study of soil bulk density and water content in a Planosol (Albaqualf) from Rio Grande do Sul State, Brazil. The minitomographer calibration was obtained from the linear regression equation among the tomography's unities (TU) presented by the image reconstruction program and the linear attenuation coefficient (µl, cm-1), by the measurement of direct transmission of g-rays as source of radiation in soil samples from A and B horizons, distilled water, benzin and aluminum. In order to get measures of the direct radiation transmission, containers with distilled water, benzin, soil and aluminum were used to obtain the following equations to calculate soil bulk density in the A horizon: Ds = [(TU/986.16)-(0.200xq)]/0.267 and in the B horizon: Ds = [(TU/986.16)-(0.200xq)]/0.297, where TU is the mean value in the line and q is the soil volumetric water content (m3 m-3). The obtained configurations allowed to attain average variabilities of 2.74% and 0.73% for homogeneity and repeatability, respectively. The expected errors related to the equipment are 0.051 and 0.046 Mg m-3, to the A and B horizons, respectively. The results showed the technique accuracy and adaptability in the studies of the physical characteristics of a Planosol

    Catálogo Taxonômico da Fauna do Brasil: setting the baseline knowledge on the animal diversity in Brazil

    Get PDF
    The limited temporal completeness and taxonomic accuracy of species lists, made available in a traditional manner in scientific publications, has always represented a problem. These lists are invariably limited to a few taxonomic groups and do not represent up-to-date knowledge of all species and classifications. In this context, the Brazilian megadiverse fauna is no exception, and the Catálogo Taxonômico da Fauna do Brasil (CTFB) (http://fauna.jbrj.gov.br/), made public in 2015, represents a database on biodiversity anchored on a list of valid and expertly recognized scientific names of animals in Brazil. The CTFB is updated in near real time by a team of more than 800 specialists. By January 1, 2024, the CTFB compiled 133,691 nominal species, with 125,138 that were considered valid. Most of the valid species were arthropods (82.3%, with more than 102,000 species) and chordates (7.69%, with over 11,000 species). These taxa were followed by a cluster composed of Mollusca (3,567 species), Platyhelminthes (2,292 species), Annelida (1,833 species), and Nematoda (1,447 species). All remaining groups had less than 1,000 species reported in Brazil, with Cnidaria (831 species), Porifera (628 species), Rotifera (606 species), and Bryozoa (520 species) representing those with more than 500 species. Analysis of the CTFB database can facilitate and direct efforts towards the discovery of new species in Brazil, but it is also fundamental in providing the best available list of valid nominal species to users, including those in science, health, conservation efforts, and any initiative involving animals. The importance of the CTFB is evidenced by the elevated number of citations in the scientific literature in diverse areas of biology, law, anthropology, education, forensic science, and veterinary science, among others

    Omecamtiv mecarbil in chronic heart failure with reduced ejection fraction, GALACTIC‐HF: baseline characteristics and comparison with contemporary clinical trials

    Get PDF
    Aims: The safety and efficacy of the novel selective cardiac myosin activator, omecamtiv mecarbil, in patients with heart failure with reduced ejection fraction (HFrEF) is tested in the Global Approach to Lowering Adverse Cardiac outcomes Through Improving Contractility in Heart Failure (GALACTIC‐HF) trial. Here we describe the baseline characteristics of participants in GALACTIC‐HF and how these compare with other contemporary trials. Methods and Results: Adults with established HFrEF, New York Heart Association functional class (NYHA) ≥ II, EF ≤35%, elevated natriuretic peptides and either current hospitalization for HF or history of hospitalization/ emergency department visit for HF within a year were randomized to either placebo or omecamtiv mecarbil (pharmacokinetic‐guided dosing: 25, 37.5 or 50 mg bid). 8256 patients [male (79%), non‐white (22%), mean age 65 years] were enrolled with a mean EF 27%, ischemic etiology in 54%, NYHA II 53% and III/IV 47%, and median NT‐proBNP 1971 pg/mL. HF therapies at baseline were among the most effectively employed in contemporary HF trials. GALACTIC‐HF randomized patients representative of recent HF registries and trials with substantial numbers of patients also having characteristics understudied in previous trials including more from North America (n = 1386), enrolled as inpatients (n = 2084), systolic blood pressure < 100 mmHg (n = 1127), estimated glomerular filtration rate < 30 mL/min/1.73 m2 (n = 528), and treated with sacubitril‐valsartan at baseline (n = 1594). Conclusions: GALACTIC‐HF enrolled a well‐treated, high‐risk population from both inpatient and outpatient settings, which will provide a definitive evaluation of the efficacy and safety of this novel therapy, as well as informing its potential future implementation

    Computed tomography scanner applied to soil compaction studies

    No full text
    O presente trabalho estuda a compactação do solo, do ponto de vista da mecânica do solo, isto é, medindo as deformações causadas por forças agindo neste. O equipamento utilizado é um tomógrafo computadorizado de primeira geração que fornece imagens, por transmissão de radiação, de seções transversais de amostras de solo (até aproximadamente 10 cm na configuração utilizada), com precisão de milímetros. Esta imagem é uma matriz de coeficientes de atenuação linear, os quais podem ser correlacionados com a densidade do solo através de uma calibração para cada solo. O trabalho se divide nos seguintes experimentos: a) experimentos básicos de calibração e resolução do equipamento; b) medidas de finas camadas de solo compactado; c) experimentos de transmissão de pressões no solo por implementos agrícolas; d) modelamento pressão-deformação em amostras de solo confinadas, com vários graus de umidade; e) levantamentos de perfis de densidade, com amostras retiradas numa trincheira, comparando com a técnica de penetrômetro. De um modo geral, os resultados evidenciaram um erro de medida da densidade e umidade entre 2 e 3% para uma dada imagem, com resolução espacial da imagem igual a 2 mm. No estudo de finas camadas de solo compactado, foi possível a quantificação de camadas compactadas maiores que 2 mm. Em experimentos de campo, após a passagem de um sulcador num Latossol Vermelho Escuro, para várias condições de densidade, umidade e peso do implemento, foram obtidos resultados desde praticamente nenhum aumento de densidade no perfil da amostra, até 0,08 g/cm3 da superfície de contato solo-implemento para baixo. No experimento com amostras coletadas numa trincheira foi obtida a caracterização de um perfil de densidade com resolução espacial igual a 2 mm, indicando existência de uma região compactada de 30 cm, com densidade de 1,3 a 1,5 g/cm3. Sondagens com o penetrômetro indicaram uma grande dependência deste com a umidade do solo. Sendo que para solo seco, o perfil do penetrômetro se assemelha muito com o perfil de densidade obtido com o TC. No estudo de modelamento pressão-deformação em amostras confinadas, obteve-se uma correlação linear da densidade com a distância da amostra, para uma carga 0,8 mPa, numa dada umidade. Por fim, conclui-se que a TC pode ser utilizada na maioria dos problemas de compactação do solo, com desempenho superior às técnicas tradicionais, tanto em problemas de modelamento pressão-deformação como em problemas de campo.The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: a) Basic experiments of equipment calibrations and resolutions studies. b) Measurements of compacted soil thin layers. c) Measurements of soil compaction caused by agricultural tools. d) Stress-strain modelling in confined soil sample, with several moisture degree. e) Characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. The results showed errors in soil bulk density and moisture content around 2% and 3%, for an image with 2 mm of spatial resolution. In compacted soil thin layer studies, was possible identified layers grater than 2 mm. Experiments of compacted soil caused by agricultural tools provided results since zero up to 0.08 g/cm3 of soil bulk density increase, in the sample profile. In the experiment with samples collected in a trench, the results shown a compacted region of 30 cm between 1,3 to 1,5 g/cm3. Measurement with cone penetrometer showed a close dependence with soil moisture content. For dry soils, the cone penetrometer profile was very similar to the soil bulk density measured by CT. Stress-strain modelling studies with confined samples, provided an approximatly linear correlation between soil bulk density and sample length, for 0,8 MPa pressure, for a constant moisture content. Finally, we concluded that the CT can be used in the study of soil compaction problems, with better performance than be traditional techniques

    Computed tomography scanner applied to soil compaction studies

    No full text
    O presente trabalho estuda a compactação do solo, do ponto de vista da mecânica do solo, isto é, medindo as deformações causadas por forças agindo neste. O equipamento utilizado é um tomógrafo computadorizado de primeira geração que fornece imagens, por transmissão de radiação, de seções transversais de amostras de solo (até aproximadamente 10 cm na configuração utilizada), com precisão de milímetros. Esta imagem é uma matriz de coeficientes de atenuação linear, os quais podem ser correlacionados com a densidade do solo através de uma calibração para cada solo. O trabalho se divide nos seguintes experimentos: a) experimentos básicos de calibração e resolução do equipamento; b) medidas de finas camadas de solo compactado; c) experimentos de transmissão de pressões no solo por implementos agrícolas; d) modelamento pressão-deformação em amostras de solo confinadas, com vários graus de umidade; e) levantamentos de perfis de densidade, com amostras retiradas numa trincheira, comparando com a técnica de penetrômetro. De um modo geral, os resultados evidenciaram um erro de medida da densidade e umidade entre 2 e 3% para uma dada imagem, com resolução espacial da imagem igual a 2 mm. No estudo de finas camadas de solo compactado, foi possível a quantificação de camadas compactadas maiores que 2 mm. Em experimentos de campo, após a passagem de um sulcador num Latossol Vermelho Escuro, para várias condições de densidade, umidade e peso do implemento, foram obtidos resultados desde praticamente nenhum aumento de densidade no perfil da amostra, até 0,08 g/cm3 da superfície de contato solo-implemento para baixo. No experimento com amostras coletadas numa trincheira foi obtida a caracterização de um perfil de densidade com resolução espacial igual a 2 mm, indicando existência de uma região compactada de 30 cm, com densidade de 1,3 a 1,5 g/cm3. Sondagens com o penetrômetro indicaram uma grande dependência deste com a umidade do solo. Sendo que para solo seco, o perfil do penetrômetro se assemelha muito com o perfil de densidade obtido com o TC. No estudo de modelamento pressão-deformação em amostras confinadas, obteve-se uma correlação linear da densidade com a distância da amostra, para uma carga 0,8 mPa, numa dada umidade. Por fim, conclui-se que a TC pode ser utilizada na maioria dos problemas de compactação do solo, com desempenho superior às técnicas tradicionais, tanto em problemas de modelamento pressão-deformação como em problemas de campo.The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: a) Basic experiments of equipment calibrations and resolutions studies. b) Measurements of compacted soil thin layers. c) Measurements of soil compaction caused by agricultural tools. d) Stress-strain modelling in confined soil sample, with several moisture degree. e) Characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. The results showed errors in soil bulk density and moisture content around 2% and 3%, for an image with 2 mm of spatial resolution. In compacted soil thin layer studies, was possible identified layers grater than 2 mm. Experiments of compacted soil caused by agricultural tools provided results since zero up to 0.08 g/cm3 of soil bulk density increase, in the sample profile. In the experiment with samples collected in a trench, the results shown a compacted region of 30 cm between 1,3 to 1,5 g/cm3. Measurement with cone penetrometer showed a close dependence with soil moisture content. For dry soils, the cone penetrometer profile was very similar to the soil bulk density measured by CT. Stress-strain modelling studies with confined samples, provided an approximatly linear correlation between soil bulk density and sample length, for 0,8 MPa pressure, for a constant moisture content. Finally, we concluded that the CT can be used in the study of soil compaction problems, with better performance than be traditional techniques
    corecore