7 research outputs found

    Treatment of thrombotic thrombocytopenic purpura [2]

    No full text
    SCOPUS: le.jinfo:eu-repo/semantics/publishe

    La maladie de Goodpasture

    No full text
    We report one case of acute renal failure with oliguria, microscopic haematuria and normocytic anemia in a 86-year old Swedish woman. A full investigation led to the diagnosis of Goodpasture disease, an isolated form of Goodpasture syndrome. Goodpasture disease is and autoimmune disorder characterized by the development of autoantibodies to the NC1 domain of the o3 chain of type IV collagen, found mainly in glomerular basement membranes (GBM). When the disease affects both the lung and the kidney, it is called Goodpasture syndrome but the pulmonary or renal involvement can be isolated or separated in years. Its pathogenesis is not well known. It occurs essentially in Caucasian subjects, preferentially from nordic and anglo-saxon countries (higher prevalence of HLA DR B1-15 and B1-4 group). Are also mentioned, the exposure to hydrocarbons, rustproof, insecticides and greasy solvents. The annual incidence of Goodpasture syndrome is rare and has been estimated in Europe to be about 0.5 to 1 case per million inhabitants. The isolated renal form represents about 1/3 of the cases. The clinical presentation is characterized by rapidly progressive renal failure with oliguria or anuria and in case of lung involvement, pulmonary hemorrhage responsible of hemoptysis, sometimes massive. Renal biopsy and immunofluorescence analysis play a key role in the diagnosis. The presence of both linear deposits of IgG along the glomerular basement membrane (GBM) and circulating anti-GBM antibodies is of paramount importance. The treatment, which depends on the degree of renal involvement, is based on the association of corticosteroids, cyclophosphamide and plasma exchanges.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    Get PDF
    BACKGROUND: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment.METHODS: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio &gt;1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes.RESULTS: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). CONCLUSIONS: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome.</p

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    No full text
    Background: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment. Methods: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio >1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes. Results: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). Conclusions: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome

    Intermediate-dose versus low-dose low-molecular-weight heparin in pregnant and post-partum women with a history of venous thromboembolism (Highlow study): an open-label, multicentre, randomised, controlled trial

    No full text
    Background: Pregnancy-related venous thromboembolism is a leading cause of maternal morbidity and mortality, and thromboprophylaxis is indicated in pregnant and post-partum women with a history of venous thromboembolism. The optimal dose of low-molecular-weight heparin to prevent recurrent venous thromboembolism in pregnancy and the post-partum period is uncertain. Methods: In this open-label, randomised, controlled trial (Highlow), pregnant women with a history of venous thromboembolism were recruited from 70 hospitals in nine countries (the Netherlands, France, Ireland, Belgium, Norway, Denmark, Canada, the USA, and Russia). Women were eligible if they were aged 18 years or older with a history of objectively confirmed venous thromboembolism, and with a gestational age of 14 weeks or less. Eligible women were randomly assigned (1:1), before 14 weeks of gestational age, using a web-based system and permuted block randomisation (block size of six), stratified by centre, to either weight-adjusted intermediate-dose or fixed low-dose low-molecular-weight heparin subcutaneously once daily until 6 weeks post partum. The primary efficacy outcome was objectively confirmed venous thromboembolism (ie, deep-vein thrombosis, pulmonary embolism, or unusual site venous thrombosis), as determined by an independent central adjudication committee, in the intention-to-treat (ITT) population (ie, all women randomly assigned to treatment). The primary safety outcome was major bleeding which included antepartum, early post-partum (within 24 h after delivery), and late post-partum major bleeding (24 h or longer after delivery until 6 weeks post partum), assessed in all women who received at least one dose of assigned treatment and had a known end of treatment date. This study is registered with ClinicalTrials.gov, NCT01828697, and is now complete. Findings: Between April 24, 2013, and Oct 31, 2020, 1339 pregnant women were screened for eligibility, of whom 1110 were randomly assigned to weight-adjusted intermediate-dose (n=555) or fixed low-dose (n=555) low-molecular-weight heparin (ITT population). Venous thromboembolism occurred in 11 (2%) of 555 women in the weight-adjusted intermediate-dose group and in 16 (3%) of 555 in the fixed low-dose group (relative risk [RR] 0·69 [95% CI 0·32–1·47]; p=0·33). Venous thromboembolism occurred antepartum in five (1%) women in the intermediate-dose group and in five (1%) women in the low-dose group, and post partum in six (1%) women and 11 (2%) women. On-treatment major bleeding in the safety population (N=1045) occurred in 23 (4%) of 520 women in the intermediate-dose group and in 20 (4%) of 525 in the low-dose group (RR 1·16 [95% CI 0·65–2·09]). Interpretation: In women with a history of venous thromboembolism, weight-adjusted intermediate-dose low-molecular-weight heparin during the combined antepartum and post-partum periods was not associated with a lower risk of recurrence than fixed low-dose low-molecular-weight heparin. These results indicate that low-dose low-molecular-weight heparin for thromboprophylaxis during pregnancy is the appropriate dose for the prevention of pregnancy-related recurrent venous thromboembolism. Funding: French Ministry of Health, Health Research Board Ireland, GSK/Aspen, and Pfizer

    Low incidence of SARS-CoV-2, risk factors of mortality and the course of illness in the French national cohort of dialysis patients

    No full text
    International audienceThe aim of this study was to estimate the incidence of COVID-19 disease in the French national population of dialysis patients, their course of illness and to identify the risk factors associated with mortality. Our study included all patients on dialysis recorded in the French REIN Registry in April 2020. Clinical characteristics at last follow-up and the evolution of COVID-19 illness severity over time were recorded for diagnosed cases (either suspicious clinical symptoms, characteristic signs on the chest scan or a positive reverse transcription polymerase chain reaction) for SARS-CoV-2. A total of 1,621 infected patients were reported on the REIN registry from March 16th, 2020 to May 4th, 2020. Of these, 344 died. The prevalence of COVID-19 patients varied from less than 1% to 10% between regions. The probability of being a case was higher in males, patients with diabetes, those in need of assistance for transfer or treated at a self-care unit. Dialysis at home was associated with a lower probability of being infected as was being a smoker, a former smoker, having an active malignancy, or peripheral vascular disease. Mortality in diagnosed cases (21%) was associated with the same causes as in the general population. Higher age, hypoalbuminemia and the presence of an ischemic heart disease were statistically independently associated with a higher risk of death. Being treated at a selfcare unit was associated with a lower risk. Thus, our study showed a relatively low frequency of COVID-19 among dialysis patients contrary to what might have been assumed

    Low incidence of SARS-CoV-2, risk factors of mortality and the course of illness in the French national cohort of dialysis patients

    No full text
    corecore