71 research outputs found

    Multianalytical study of patina formed on archaeological metal objects from Bliesbruck-Reinheim

    Get PDF
    Patinas naturally formed on archaeological bronze alloys were characterized using light microscopy (LM), micro energy dispersive X-ray fluorescence analysis (mu-EDXRF), time of flight secondary ion mass spectrometry (TOF-SIMS) and scanning electron microscopy in combination with energy dispersive X-ray microanalysis (SEM/EDX). The examinations carried out on cross-sections of samples have shown that in all samples the copper content in the corrosion layer is lower than in the bulk, while an increase of tin and lead could be observed. Two different types of corrosion were found: first type, a corrosion formation leading to a three layer structure was observed on lead bronze. The outer layer consists mainly of Cu(II) compounds and soil material, followed by a fragmented layer of cuprous oxide and the surface layer of the alloy, where a depletion of copper and an enrichment of tin and high amounts of Cl could be detected, The second type of corrosion is characterized by a two layer structure on the tin bronze sample consisting of an outer layer with copper containing corrosion products and a layer with cracks, which reveals a depletion of copper whereas tin and lead are enriched. Also high amounts of Si were detected in this surface layer

    Analysis of C/E results of fission rate ratio measurements in several fast lead VENUS-F cores

    Get PDF
    During the GUINEVERE FP6 European project (2006-2011), the zero-power VENUS water-moderated reactor was modified into VENUS-F, a mockup of lead cooled fast spectrum system with solid components that can be operated in both critical and subcritical mode. The Fast Reactor Experiments for hybrid Applications (FREYA) FP7 project was launched in 2011 to support the designs of the MYRRHA Accelerator Driven System (ADS) and the ALFRED Lead Fast Reactor (LFR). Three VENUS-F critical core configurations, simulating the complex MYRRHA core design and one configuration devoted to the LFR ALFRED core conditions were investigated in 2015. The MYRRHA related cores simulated step by step design peculiarities like the BeO reflector and in pile sections. For all of these cores the fuel assemblies were of a simple design consisting of 30 % enriched metallic uranium, lead rodlets to simulate the coolant and Al2O3 rodlets to simulate the oxide fuel. Fission rate ratios of minor actinides such as Np-237, Am-241 as well as Pu-239, Pu-240, Pu-242 and U-238 to U-235 were measured in these VENUS-F critical assemblies with small fission chambers in specially designed locations, to determine the spectral indices in the different neutron spectrum conditions. The measurements have been analyzed using advanced computational tools including deterministic and stochastic codes and different nuclear data sets like JEFF-3.1, JEFF-3.2, ENDF/B7.1, ENDF/B6.8, JENDL-4.0 and TENDL-2014. The analysis of the C/E discrepancies will help to improve the nuclear data in the specific energy region of fast neutron reactor spectra

    The GUINEVERE Project for Accelerator Driven System Physics

    No full text
    paper 9414International audienceThe GUINEVERE project is part of the EUROTRANS Integrated Project of the 6th EURATOM Framework Programme. It is mainly devoted to ADS on-line reactivity monitoring validation, sub-criticality determination and operational procedures (loading, start-up, shut-down, ...) as a follow-up of the MUSE experiments. The project consists in coupling a fast lead core, set-up in the VENUS reactor at SCK*CEN Mol (B), with a GENEPI neutron source under construction by CNRS. To accommodate the accelerator in a vertical coupling configuration, the VENUS building is being heightened. The fast core will be loaded with enriched Uranium and will be moderated and reflected with solid lead (zero power experiment). For the purpose of the experimental programme, the neutron source has to be operated not only in pulsed mode but also in continuous mode to investigate the current-to-flux reactivity indicator in representative conditions of a powerful ADS. In this latter mode it is also required to make short beam interruptions to have access to the neutron population decrease as a function of time: from this spectrum it will be possible to apply different analysis techniques such as "prompt decay" fitting techniques and "source jerk" techniques. Beam interruptions will be repeated at a programmable frequency to improve time spectra statistics. Different sub-criticality levels (keff=0.99, 0.97, 0.95, ...) will be investigated in order to obtain a full set of data points for the final overall validation of the methodology. This paper describes the status of the experimental facility assembling, and the foreseen experimental programme to be started

    The GUINEVERE project at the VENUS facility

    No full text
    Proc. on CD Rom log315International audienceThe GUINEVERE project is an international project in the framework of IP-EUROTRANS, the FP6 program which aims at addressing the main issues for ADS development in the framework of partitioning and transmutation for nuclear waste volume and radiotoxicity reduction. The GUINEVERE project is carried out in the context of domain 2 of IP-EUROTRANS, ECATS, devoted to specific experiments for the coupling of an accelerator, a target and a subcritical core. These experiments should provide an answer to the questions of online reactivity monitoring, sub-criticality determination and operational procedures (loading, start-up, shutdown, …) in an ADS by 2009-2010. The project has the objective to couple a fast lead core, within the VENUS building operated by the SCK•CEN, with a neutron generator able to work in three different modes: pulsed, continuous and continuous with beam interruptions at the millisecond scale. In order to achieve this goal, the VENUS facility has to be adapted and a modified GENEPI-3C accelerator has to be designed and constructed. The paper describes the main modifications to the reactor core and facility and to the accelerator, which will be executed during the years 2008 and 2009, and the experimental programme which will start in 2009

    THE APPLICABILITY RANGE OF THE MODIFIED SOURCE MULTIPLICATION (MSM) METHOD TESTED IN THE FAST VENUS-F REACTOR

    Get PDF
    The MSM method is an experimental technique for determination of reactivity of a sub-critical reactor. It consists of one dynamic measurement followed by two static measurements, which use an extraneous neutron source. For the data analysis, the core averaged kinetic parameters need to be calculated as well as a spatially-dependent correction factor that corrects for the point kinetics approximation. In order to test the range for which the method is valid and to demonstrate the reliability of the correction factor calculations in a fast reactor, a dedicated experimental campaign was performed in the fast lead-bismuth VENUS-F reactor. The reactivity of a dozen of sub-critical configurations was measured with the MSM method using ten 235U fission chambers. The detectors were located at various distances from the active zone and from the extraneous neutron source, leading to a large range of values of a correction factor (calculated with the Monte Carlo MCNP5 code) used in the data analysis

    THE APPLICABILITY RANGE OF THE MODIFIED SOURCE MULTIPLICATION (MSM) METHOD TESTED IN THE FAST VENUS-F REACTOR

    No full text
    The MSM method is an experimental technique for determination of reactivity of a sub-critical reactor. It consists of one dynamic measurement followed by two static measurements, which use an extraneous neutron source. For the data analysis, the core averaged kinetic parameters need to be calculated as well as a spatially-dependent correction factor that corrects for the point kinetics approximation. In order to test the range for which the method is valid and to demonstrate the reliability of the correction factor calculations in a fast reactor, a dedicated experimental campaign was performed in the fast lead-bismuth VENUS-F reactor. The reactivity of a dozen of sub-critical configurations was measured with the MSM method using ten 235U fission chambers. The detectors were located at various distances from the active zone and from the extraneous neutron source, leading to a large range of values of a correction factor (calculated with the Monte Carlo MCNP5 code) used in the data analysis
    corecore