10 research outputs found
Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants
BACKGROUND:Over the past 30-40years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8years.METHODS:Mandibular reconstruction (8-10years ago) was performed with pure (99.99%) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8years to a sterilized, but not implanted one.RESULTS:Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants.CONCLUSIONS:The surface morphology and the structure were not changed after 8years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates
Influence of gold nanoparticles on collagen fibril morphology quantified using transmission electron microscopy and image analysis
BACKGROUND: Development of implantable biosensors for disease detection is challenging because of poor biocompatibility of synthetic materials. A possible solution involves engineering interface materials that promote selfassembly and adhesion of autologous cells on sensor surfaces. Crosslinked type-I collagen is an acceptable material for developing engineered basement membranes. In this study, we used functionalized gold nanoparticles as the crosslinking agent. Functionalized nanoparticles provide sites for crosslinking collagen as well as sites to deliver signaling compounds that direct selfassembly and reduce inflammation. The goal of this study was to obtain a quantitative parameter to objectively determine the presence of crosslinks. METHODS: We analyzed TEM images of collagen fibrils by two methods: Run length analysis and topology analysis after medial axis transform. RESULTS: Run length analysis showed a significant reduction of the interfibril spaces in the presence of nanoparticles (change of 40%, P < 0.05), whereas the fibril thickness remained unchanged. In the topological network, the number of elements, number of branches and number of sides increased significantly in the presence of nanoparticles (P < 0.05). Other parameters, especially the number of loops showed only a minimal and nonsignificant change. We chose a ratiometric parameter of the number of branches normalized by the number of loops to achieve independence from gross fibril density. This parameter is lower by a factor of 2.8 in the presence of nanoparticles (P < 0.05). CONCLUSION: The numerical parameters presented herein allow not only to quantify fibril mesh complexity and crosslinking, but also to help quantitatively compare cell growth and adhesion on collagen matrices of different degree of crosslinking in further studies
In vitro and in vivo studies on biocompatibility of carbon fibres
In the present study we focused on the in vitro and in vivo evaluation of two types of carbon fibres (CFs): hydroxyapatite modified carbon fibres and porous carbon fibres. Porous CFs used as scaffold for tissues regeneration could simultaneously serve as a support for drug delivery or biologically active agents which would stimulate the tissue growth; while addition of nanohydroxyapatite to CFs precursor can modify their biological properties (such as bioactivity) without subsequent surface modifications, making the process cost and time effective. Presented results indicated that fibre modification with HAp promoted formation of apatite on the fibre surface during incubation in simulated body fluid. The materials biocompatibility was determined by culturing human osteoblast-like cells of the line MG 63 in contact with both types of CFs. Both tested materials gave good support to adhesion and growth of bone-derived cells. Materials were implanted into the skeletal rat muscle and a comparative analysis of tissue reaction to the presence of the two types of CFs was done. Activities of marker metabolic enzymes: cytochrome c oxidase (CCO) and acid phosphatase were examined to estimate the effect of implants on the metabolic state of surrounding tissues. Presented results evidence the biocompatibility of porous CFs and activity that stimulates the growth of connective tissues. In case of CFs modified with hydroxyapatite the time of inflammatory reaction was shorter than in case of traditional CFs
Autoantibodies can be prognostic markers of an erosive disease in early rheumatoid arthritis
Objective: To evaluate a contribution of selected laboratory parameters for a prediction of progressive and erosive development in patients with early rheumatoid arthritis (RA). Methods: In a prospective study baseline levels of antibodies to cyclic citrullinated peptide (anti-CCP), IgM, IgA, and IgG rheumatoid factors (RFs) were measured by enzyme linked immunosorbent assay (ELISA) in 104 patients with RA with disease duration <2 years. Antikeratin antibodies (AKA) and antiperinuclear factor (APF) were detected by indirect immunofluorescence. Patients were divided into two groups based either on the presence or absence of erosions or according to progression of Larsen score at the end of the 24 months' follow up. Results: Sixty seven (64%) patients developed radiographic erosions, 49 (47%) had progression in Larsen score, and 36 (35%) progressed by more than 10 Larsen units. Significant differences in erosions and progression between the two groups were detected for anti-CCP, AKA, APF, IgM RF, IgA RF, and IgG RF. Baseline Larsen score correlated significantly with anti-CCP, IgM RF, and IgA RF levels, and all measured antibodies correlated with the progression >10 units. The combination of anti-CCP and IgM RF increased the ability to predict erosive and progressive disease. Conclusion: The data confirmed that measurement of anti-CCP, AKA, APF, and individual isotypes of RFs was useful for prediction of structural damage early in the disease course. Combined analysis of anti-CCP and IgM RF provides the most accurate prediction