36 research outputs found

    Feasibility of a Small, Rapid Optical-to-IR Response, Next Generation Gamma Ray Burst Mission

    Full text link
    We present motivations for and study feasibility of a small, rapid optical to IR response gamma ray burst (GRB) space observatory. By analyzing existing GRB data, we give realistic detection rates for X-ray and optical/IR instruments of modest size under actual flight conditions. Given new capabilities of fast optical/IR response (about 1 s to target) and simultaneous multi-band imaging, such an observatory can have a reasonable event rate, likely leading to new science. Requiring a Swift-like orbit, duty cycle, and observing constraints, a Swift-BAT scaled down to 190 square cm of detector area would still detect and locate about 27 GRB per yr. for a trigger threshold of 6.5 sigma. About 23 percent of X-ray located GRB would be detected optically for a 10 cm diameter instrument (about 6 per yr. for the 6.5 sigma X-ray trigger).Comment: Elaborated text version of a poster presented at 2012 Malaga/Marbella symposiu

    Analysis of the availability of medicines for the treatment of servicemen with injury and wound of the brain

    Get PDF
    The most important areas that determine the effectiveness of the medical support system at all stages of providing medical assistance to servicemen is the rational use and availability of medicines and pharmaceutical assistance in general. Under the influence of the situation in eastern Ukraine, the instability of the market economy, the existing budget deficit for the military medical service, the availability of certain groups of drugs is of particular relevance, which fully applies to drugs for the pharmacotherapy of injuries and brain injuries. The purpose of the study is to analyze the availability of medicines for pharmacotherapy of injuries and wounds of the brain. In conducting the study, the following methods of analysis were used: system-review, bibliographic and marketing. Analysis of scientific literature data showed that for pharmacotherapy of craniocerebral wounds and injuries such groups of drugs as psychoanaleptics (N06), blood substitutes and perfusion solutions (B05), peripheral vasodilators (C04), calcium antagonists (C08), analgesics (N02) are used. and psycholeptic drugs (N05), etc., which counted 1 300 trade names of drugs. The analysis of the pharmaceutical market in recent years has allowed us to single out three main factors (index) affecting the growth of expenditures on drug provision for servicemen, the replacement index; inflation index; innovation index Analyzing the availability of drugs by price proposals, it was found that the number of inaccessible drugs decreased within five years by more than 30% and amounts to 7.93% or 103 drugs from the total range of drugs for medical support of servicemen with injury and wound of the brain. That is why it is advisable to conclude that the replacement index has almost no effect on reducing the level of drug costs for servicemen/ In the study of the inflation index, it was found that the pricing of domestic drugs depends on the level of inflation, the cost of foreign-made drugs is in direct proportion to the growth of the dollar. Analysis of the innovation index of the domestic drug market for medical support of servicemen with injury and wound of the brain showed that only 77 original drugs are used for pharmacotherapy, which is 5.92% of the total number of drugs

    The detection of neutrino interactions in the emulsion/lead target of the OPERA experiment

    Full text link
    The OPERA neutrino detector in the underground Gran Sasso Laboratory (LNGS) was designed to perform the first detection of neutrino oscillations in appearance mode through the study of νμντ\nu_\mu\to\nu_\tau oscillations. The apparatus consists of an emulsion/lead target complemented by electronic detectors and it is placed in the high energy long-baseline CERN to LNGS beam (CNGS) 730 km away from the neutrino source. Runs with CNGS neutrinos were successfully carried out in 2007 and 2008 with the detector fully operational with its related facilities for the emulsion handling and analysis. After a brief description of the beam and of the experimental setup we report on the collection, reconstruction and analysis procedures of first samples of neutrino interaction events

    Emulsion sheet doublets as interface trackers for the OPERA experiment

    Get PDF
    New methods for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units ("ECC bricks"). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronically tagged penetrating muons. Further improvement of in-doublet film alignment was obtained by matching the pattern of low-energy electron tracks. The commissioning of the overall OPERA alignment procedure is in progress.Comment: 19 pages, 19 figure

    Measurement of the atmospheric muon charge ratio with the OPERA detector

    Get PDF
    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the charge ratio dependence on the primary composition. The measured charge ratio values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the "vertical surface energy". A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.Comment: 14 pages, 10 figure

    Study of the effects induced by lead on the emulsion films of the OPERA experiment

    Get PDF
    The OPERA neutrino oscillation experiment is based on the use of the Emulsion Cloud Chamber (ECC). In the OPERA ECC, nuclear emulsion films acting as very high precision tracking detectors are interleaved with lead plates providing a massive target for neutrino interactions. We report on studies related to the effects occurring from the contact between emulsion and lead. A low radioactivity lead is required in order to minimize the number of background tracks in emulsions and to achieve the required performance in the reconstruction of neutrino events. It was observed that adding other chemical elements to the lead, in order to improve the mechanical properties, may significantly increase the level of radioactivity on the emulsions. A detailed study was made in order to choose a lead alloy with good mechanical properties and an appropriate packing technique so as to have a low enough effective radioactivity.Comment: 19 pages, 11 figure

    Observation of a first ντ\nu_\tau candidate in the OPERA experiment in the CNGS beam

    Get PDF
    The OPERA neutrino detector in the underground Gran Sasso Laboratory (LNGS) has been designed to perform the first detection of neutrino oscillations in direct appearance mode through the study of the νμντ\nu_\mu\rightarrow\nu_\tau channel. The hybrid apparatus consists of an emulsion/lead target complemented by electronic detectors and it is placed in the high energy long-baseline CERN to LNGS beam (CNGS) 730 km away from the neutrino source. Runs with CNGS neutrinos were successfully carried out in 2008 and 2009. After a brief description of the beam, the experimental setup and the procedures used for the analysis of the neutrino events, we describe the topology and kinematics of a first candidate ντ\nu_\tau charged-current event satisfying the kinematical selection criteria. The background calculations and their cross-check are explained in detail and the significance of the event is assessed.Comment: 19 pages, 3 figure
    corecore