5 research outputs found

    Tevatron Beam Halo Collimation System: Design, Operational Experience and New Methods

    Full text link
    Collimation of proton and antiproton beams in the Tevatron collider is required to protect CDF and D0 detectors and minimize their background rates, to keep irradiation of superconducting magnets under control, to maintain long-term operational reliability, and to reduce the impact of beam-induced radiation on the environment. In this article we briefly describe the design, practical implementation and performance of the collider collimation system, methods to control transverse and longitudinal beam halo and two novel collimation techniques tested in the Tevatron.Comment: 25 p

    Fermilab-Conf-11-127-APC ADVANCED BENT CRYSTAL COLLIMATION STUDIES AT THE TEVATRON (T-980) Advanced Bent Crystal Collimation Studies at the Tevatron (T-980)*

    No full text
    Abstract The T-980 bent crystal collimation experiment at the Tevatron Abstract The T-980 bent crystal collimation experiment at the Tevatron [1, 2] has recently acquired substantial enhancements. First, two new crystals -a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics, electronics, control and software has been manufactured, tested and installed in the E0 crystal region. The purpose of the pixel telescope is to measure and image channeled (CH), volume-reflected (VR) and multiple volume-reflected (MVR) beam profiles produced by bent crystals. Third, an ORIGIN-based system has been developed for thorough analysis of experimental and simulation data. Results of analysis are presented for different types of crystals used from 2005 to present for channeling and volume reflection including pioneering tests of two-plane crystal collimation at the collider, all in comparison with detailed simulations

    Recent T980 Crystal Collimation Studies at the Tevatron Exploiting a Pixel Detector System and a Multi-strip Crystal Array

    No full text
    With the shutdown of the Tevatron, the T-980 crystal collimation experiment at Fermilab has been successfully completed. Results of dedicated beam studies in May 2011 are described in this paper. For these studies, two multi-strip crystals were installed in the vertical goniometer and an O-shaped crystal installed in a horizontal goniometer. A two-plane CMS pixel detector was also installed in order to enhance the experiment with the capability to image the profile of crystal channeled or multiple volume reflected beam. The experiment successfully imaged channeled beam from a crystal for 980-GeV protons for the first time. This new enhanced hardware yielded impressive results. The performance and characterization of the crystals studied have been very reproducible over time and consistent with simulations
    corecore