142 research outputs found

    Study of the temperature influence on the directions of stable gas condensate transformations in the zeoforming process

    Get PDF
    In this work influence of temperature on directions of stable gas condensate transformation in zeoforming process was investigated

    Angiographic predictors of recurrence of restenosis after Wiktor stent implantation in native coronary arteries

    Get PDF
    Intracoronary stenting has been proposed as an adjunct to balloon angioplasty to improve the immediate and long-term results. However, late luminal narrowing has been reported following the implantation of a variety of stents. One of the studies conducted with the Wiktor stent is a prospective registry designed to evaluate the feasibility, safety and efficacy of elective stent implantation in patients with documented restenosis of a native coronary artery. To identify angiographic variables predicting recurrence of restenosis, the angiograms of the first 91 patients with successful stent implantation and without clinical evidence of (sub)acute thrombotic stent occlusion were analyzed with the Computer Assisted Angiographic Analysis System using automated edge detection. The incidence of restenosis was 44% by patient and 45% by stent according to the 0.72 mm criterion, and 30% by patient and 29% by stent according to the 50% diameter stenosis criterion. The risk for restenosis for several angiographic variables was determined using an univariate analysis and is expressed as odds ratio with corresponding confidence interval. The only statistically significant predictor of restenosis was the relative gain when it exceeded 0.48 using the 0.72 mm criterion (odds ratio 2.7, 95% confidence interval 1.1-6.4). Furthermore, the relation between the relative gain (increase in minimal luminal diameter normalized to vessel size) as angiographic index of vessel wall injury and relative loss (decrease in minimal luminal diameter normalized to vessel size) as index of neointimal thickening was analyzed using a linear regression analysis. When using the categorical approach to address restenosis, there is an increased risk for recurrent restenosis when the relative gain exceeds 0.48. The continuous approach underscores this concept by indicating a weak but positive relation between the relative gain and relative loss

    Экономическое обоснование проекта «Доставка здорового питания»

    Get PDF
    Объектом исследования является рынок услуг, оказывающий доставку здорового питания Цель работы - обоснование открытия интернет – магазина доставки здорового питания В ходе работы решены следующие задачи: 1 проведён обзор литературы 2 проанализирован рынок здорового питания; 3 дан анализ потребительских предпочтений относительно здорового питания 4 экономически обосновано открытие интернет – магазина доставки здорового питания; 5 проведён анализ всевозможных рисков, связанных с открытием интернет - магазина.The object of the study is the market for services providing healthy food delivery. Purpose of work – substantiation of the opening of an online store of healthy food delivery In the course of work, the following tasks were solved: 1 literature review 2 analyzed the market for healthy eating; 3 gives an analysis of consumer preferences regarding healthy eating. 4 it is economically justified to open an online health food delivery store; 5 an analysis of all possible risks associated with the opening of an online store

    Recoil following Wiktor stent implantation for restenotic lesions of coronary arteries

    Get PDF
    The purpose of this study was to determine acute recoil of the vessel wall immediately after Wiktor stent implantation in native coronary arteries of 77 consecutive patients and to assess whether there was compression or “late recoil” of the stent itself at long-term follow-up. Furthermore, the relationship between recoil and a number of clinical, angiographic, and procedural variables was studied in addition to the relation between acute recoil renarrowing or restenosis was assessed. All angiograms were analyzed with the Cardiovascular Angiography Analysis System using automated edge detection. Acute recoil was defined by the difference between the mean diameter of the fully expanded balloon on which the stent was mounted and the mean diameter of the stented segment. Late recoil was calculated by comparing the mean diameter of the stent itself immediately after implantation and at follow-up without opacification of the vessel. Acute recoil amounted to 0.25 ± 0.32 mm or 8.2%. Multivariate analysis identified sex (coefficient = –0.20, p = 0.04) and stent/artery ratio (coefficient = 0.99, p = 0.0001) as the only independent predictors of acute recoil. “Late recoil” of the stent itself was not observed. The overall difference between the mean diameter of the stent itself immediately after implantation and at follow-up was –0.15 ± 0.33 mm, suggesting an overall increase in diameter of 5.0%. There was no relation between acute recoil and late restenosis. On the contrary, there was a trend towards a greater degree of recoil in patients without restenosis. Moreover, linear regression analysis disclosed a weak but negative correlation between acute recoil and a loss in minimal luminal diameter (coefficient: –0.55, p = 0.04). The Wiktor stent effectively scaffolds the instrumented vessel. Only a minimal amount of acute recoil was noted, which did not contribute to late luminal renarrowing or restenosis. In addition, no late compression of the stent itself was observed. These data suggest that tissue ingrowth into the lumen of the stented segment is the main cause of late luminal renarrowing after stent implantation. © 1994 Wiley-Liss,Inc.

    Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty

    Get PDF
    Major, adverse cardiac events (death, myocardial infarction, bypass surgery and reintervention) occur in 4 to 7% of all patients undergoing coronary balloon angioplasty. Prospectively collected clinical data, and angiographic quantitative and qualitative lesion morphologic assessment and procedural factors were examined to determine whether the occurrence of these events could be predicted. Of 1,442 patients undergoing balloon angioplasty for native primary coronary disease in 2 European multicenter trials, 69 had major, adverse cardiac procedural or in-hospital complications after ≥1 balloon inflation and were randomly matched with patients who completed an uncomplicated in-hospital course after successful angioplasty. No quantitative angiographic variable was associated with major adverse cardiac events in univariate and multivariate analyses. Univariate analysis showed that major adverse cardiac events were associated with the following preprocedural variables: (1) unstable angina (odds ratio [OR] 3.11; p 45 ° (OR 2.34; p 45 ° (OR 2.87; p 45 ° (OR 2.54; p < 0.006) were independent predictors of major adverse cardiac events

    Thrombolysis with tissue plasminogen activator in acute myocardial infarction: no additional benefit from immediate percutaneous coronary angioplasty

    Get PDF
    A randomised trial of 367 patients with acute myocardial infarction was performed to determine whether an invasive strategy combining thrombolysis with recombinant tissue-type plasminogen activator (rTPA), heparin, and acetylsalicylic acid, and immediate percutaneous transluminal coronary angioplasty (PTCA) would be superior to a noninvasive strategy with the same medical treatment but without immediate angiography and PTCA. Intravenous infusion of 100 mg rTPA was started within 5 h after onset of symptoms (median 156 min). Angiography was performed 6-165 min later in 180 out of 183 patients allocated to the invasive strategy; 184 patients were allocated to the non-invasive strategy. Immediate PTCA reduced the percentage stenosis of the infarc
    corecore