164 research outputs found

    Identification of Vascularised Carotid Plaques Using a Standardised and Reproducible Technique to Measure Ultrasound Contrast Uptake

    Get PDF
    ObjectivesContrast-enhanced ultrasonography (CEUS) has been used to assess the vascularisation of carotid plaques. Our aim was to develop and validate a standardised semi-automated method for CEUS examination of plaques, and test if the technique could be used to identify vulnerable plaques.MethodsStudy participants were a mixed population of symptomatic and asymptomatic subjects, selected if they had a plaque with height >2.5 mm and <10% acoustic shadowing. Participants received a bolus of ultrasound contrast agent and a 90-s cine-loop was captured. A Contrast Quantification Program (CQP) was developed and trained to identify extent of contrast uptake after motion correction and application of a noise reduction algorithm. The technique was validated by comparing CQP values with visual assessment of contrast uptake. CQP values were also compared with plaque echogenicity and history of clinical events.ResultsCQP values correlated with a visual, 5-scale classification of contrast uptake by two blinded, experienced sonographers. Repeated contrast injections showed high reproducibility. Participants with a history of ipsilateral stroke/TIA had significantly higher CQP values than asymptomatic participants.ConclusionWe present a reproducible, semi-automatic method to identify vascularisation of carotid plaques, which could be used in prospective studies to determine the clinical value of plaque vascularisation

    Real-time imaging required for optimal echocardiographic assessment of aortic valve calcification

    Get PDF
    Introduction Aortic valve calcification (AVC), even without haemodynamic significance, may be prognostically import as an expression of generalized atherosclerosis, but techniques for echocardiographic assessment are essentially unexplored. Methods Two-dimensional (2D) echocardiographic recordings (Philips IE33) of the aortic valve in short-axis and long-axis views were performed in 185 consecutive patients within 1 week before surgery for aortic stenosis (n = 109, AS), aortic regurgitation (n = 61, AR), their combination (n = 8) or dilation of the ascending aorta (n = 7). The grey scale mean (GSMn) of the aortic valve in an end-diastolic short-axis still frame was measured. The same frame was scored visually 15 as indicating that the aortic valve was normal, thick, or had mild, moderate or severe calcification. The visual echodensity of each leaflet was determined real time applying the same 5-grade scoring system for each leaflet, and the average for the whole valve was calculated. Finally, a similar calcification score for the whole valve based on inspection and palpation by the surgeon was noted. Results Visual assessment of real-time images using the proposed scoring system showed better correlation with the surgical evaluation of the degree of valve calcification (r = 0.83, P<0.001) compared to evaluation of stop frames by visual assessment (r = 0.66, P<0.001) or the GSMn score (r = 0.64, P<0.001). High inter- and intra-observer correlations were observed for real-time visual score (both intraclass correlation coefficient = 0.93). Conclusion Real-time evaluation of the level of AVC is superior to using stop frames assessed either visually or by dedicated computer grey scale measurement software

    Prototyping of petalets for the Phase-II Upgrade of the silicon strip tracking detector of the ATLAS Experiment

    Full text link
    In the high luminosity era of the Large Hadron Collider, the HL-LHC, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and exploits the concept of modularity. Prototyping and testing of various strip detector components has been carried out. This paper presents the developments and results obtained with reduced-size structures equivalent to those foreseen to be used in the forward region of the silicon strip detector. Referred to as petalets, these structures are built around a composite sandwich with embedded cooling pipes and electrical tapes for routing the signals and power. Detector modules built using electronic flex boards and silicon strip sensors are glued on both the front and back side surfaces of the carbon structure. Details are given on the assembly, testing and evaluation of several petalets. Measurement results of both mechanical and electrical quantities are shown. Moreover, an outlook is given for improved prototyping plans for large structures.Comment: 22 pages for submission for Journal of Instrumentatio

    Glacial to Holocene terrigenous organic matter input to sediments from Orca Basin, Gulf of Mexico — A combined optical and biomarker approach

    Get PDF
    In this study we assessed changes in the contribution of terrigenous organic matter (OM) to the Gulf of Mexico over the course of the last deglaciation (the last 25 kyr). To this end, we combined optical kerogen analyses with bulk sedimentary, biomarker, and compound-specific carbon isotope analyses. Samples were obtained from core MD02-2550 from Orca Basin (2249 m water depth at 26°56.77N, 91°20.74W) with temporal resolution ranging from multi-decadal to millennial-scale, depending on the proxy. All proxies confirmed larger terrigenous input during glacial times compared to the Holocene. In addition, the kerogen analyses suggest that much of the glacial OM is reworked (at least 50% of spores and pollen grains and 40% of dinoflagellate cysts). The Holocene sediments, in contrast, contain mainly marine OM, which is exceptionally well preserved. During the deglaciation, terrigenous input was generally high due to large meltwater fluxes, whereby discrepancies between different proxies call for additional influences, such as the change in distance to the river mouth, local productivity changes, and hydrodynamic particle sorting. It is possible that kerogen particles and the terrigenous biomarkers studied here represent distinct pools of land-derived OM with inputs varying independently

    Precision of the current methods to measure the alkenone proxy UK'37 and absolute alkenone abundance in sediments : results of an interlaboratory comparison study

    Get PDF
    Measurements of the UK'37 index and the absolute abundance of alkenones in marine sediments are increasingly used in paleoceanographic research as proxies of past sea surface temperature and haptophyte (mainly coccolith-bearing species) primary productivity, respectively. An important aspect of these studies is to be able to compare reliably data obtained by different laboratories from a wide variety of locations. Hence the intercomparability of data produced by the research community is essential. Here we report results from an anonymous interlaboratory comparison study involving 24 of the leading laboratories that carry out alkenone measurements worldwide. The majority of laboratories produce data that are intercomparable within the considered confidence limits. For the measurement of alkenone concentrations, however, there are systematic biases between laboratories, which might be related to the techniques employed to quantify the components. The maximum difference between any two laboratories for any two single measurements of UK'37 in sediments is estimated, with a probability of 95%, to be <2.18C. In addition, the overall within-laboratory precision for the UK'37 temperature estimates is estimated to be <1.68C (95% probability). Similarly, from the analyses of alkenone concentrations the interlaboratory reproducibility is estimated at 32%, and the repeatability is estimated at 24%. The former is compared to a theoretical estimate of reproducibility and found to be excessively high. Hence there is certainly scope and a demonstrable need to improve reproducibility and repeatability of UK'37 and especially alkenone quantification data across the community of scientists involved in alkenone research

    Deformation-induced microstructural banding in TRIP steels

    Get PDF
    Microstructure inhomogeneities can strongly influence the mechanical properties of advanced high-strength steels in a detrimental manner. This study of a transformation-induced plasticity (TRIP) steel investigates the effect of pre-existing contiguous grain boundary networks (CGBNs) of hard second-phases and shows how these develop into bands during tensile testing using in situ observations in conjunction with digital image correlation (DIC). The bands form by the lateral contraction of the soft ferrite matrix, which rotates and displaces the CGBNs of second-phases and the individual features within them to become aligned with the loading direction. The more extensive pre-existing CGBNs that were before the deformation already aligned with the loading direction are the most critical microstructural feature for damage initiation and propagation. They induce micro-void formation between the hard second-phases along them, which coalesce and develop into long macroscopic fissures. The hard phases, retained austenite and martensite, were not differentiated as it was found that the individual phases do not play a role in the formation of these bands. It is suggested that minimizing the presence of CGBNs of hard second-phases in the initial microstructure will increase the formability

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Full text link
    The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.Comment: 54 pages, 48 picture

    Imaging of Functional Connectivity in the Mouse Brain

    Get PDF
    Functional neuroimaging (e.g., with fMRI) has been difficult to perform in mice, making it challenging to translate between human fMRI studies and molecular and genetic mechanisms. A method to easily perform large-scale functional neuroimaging in mice would enable the discovery of functional correlates of genetic manipulations and bridge with mouse models of disease. To satisfy this need, we combined resting-state functional connectivity mapping with optical intrinsic signal imaging (fcOIS). We demonstrate functional connectivity in mice through highly detailed fcOIS mapping of resting-state networks across most of the cerebral cortex. Synthesis of multiple network connectivity patterns through iterative parcellation and clustering provides a comprehensive map of the functional neuroarchitecture and demonstrates identification of the major functional regions of the mouse cerebral cortex. The method relies on simple and relatively inexpensive camera-based equipment, does not require exogenous contrast agents and involves only reflection of the scalp (the skull remains intact) making it minimally invasive. In principle, fcOIS allows new paradigms linking human neuroscience with the power of molecular/genetic manipulations in mouse models
    • …
    corecore