1,335 research outputs found
Contrast medium-induced nephropathy, a more practical approach to prevention?
To The Editor: we read with interest the good review article by Drs Sterner and Nyman [1] concerning the safe use of intravascular contrast medium for both coronary interventions and multi-channel detector computed tomography. see the full text of the articl
Nucleon-nucleon potential in finite nuclei
We consider the spin-isospin-independent central part of the residual
nucleon-nucleon potential in finite spherical nuclei taking into account the
deformation effects of the nucleons within the surrounding nuclear environment.
It is shown that inside the nucleus the short-range repulsive contribution of
the potential is increased and the intermediate attraction is decreased. We
identify the growth of the radial component of the spin-isospin independent
short-range part of the in-medium nucleon-nucleon interaction as the
responsible agent that prevents the radial collapse of the nucleus.Comment: 9 pages, 3 eps figure
Looking for the S-Z Effect towards Distant ROSAT Clusters of Galaxies
We report on observations of the Sunyaev-Zeldovich effect towards X-ray ROSAT
clusters taken with a double channel (1.2 and 2 mm) photometer installed at the
focus of the 15m SEST antenna in Chile. This paper describes the first results
obtained for the high-z clusters S1077, A2744 and S295. Marginal detections
were found for A2744 and at 1 mm for S1077. We discuss these data in terms of
contamination of sources along the line of sight and give a constraint on the
amplitude of the kinematic effect.Comment: 17 pg Latex file (using aasms4.sty) gzip'd tar'd uuencoded file
including 1 ps figure, ApJ Letter in pres
Improved estimation of glomerular filtration rate (GFR) by comparison of eGFRcystatin C and eGFRcreatinine
Objective. GFR-prediction equations based upon cystatin C and creatinine have better diagnostic performance in estimating GFR than equations based upon only one of the two markers. The present work concerns in what way a comparison between separate estimations of GFR based upon cystatin C (eGFR(cystatin C)) or creatinine (eGFR(creatinine)) can be used to evaluate the diagnostic performance of a combined cystatin C-and creatinine-based estimation of GFR. Methods. The difference between eGFR(cystatin C) and eGFR(creatinine) was compared with measured GFR (iohexol clearance) and a combined cystatin C- and creatinine-based estimation of GFR in a Swedish-Caucasian cohort of 857 adult patients. Results. A difference between eGFR(cystatin C) and eGFR(creatinine) of >= 40% indicated a markedly reduced diagnostic performance of the combined cystatin C- and creatinine-based estimation of GFR. Conclusion. Comparison of the agreement between eGFR(cystatin C) and eGFR(creatinine) can be used to evaluate the diagnostic performance of combined cystatin C-and creatinine-based estimations of GFR. If 'threshold values' for discordance are exceeded, it must be considered whether the clinical context requires the use of an invasive gold standard method to measure GFR. In some clinical contexts either creatinine or cystatin C are known to be invalidated as markers of GFR and in these situations the use of only the cystatin C-or the creatinine-based GFR estimate should be considered when the 'threshold values' are exceeded
First observations with CONDOR, a 1.5 THz heterodyne receiver
The THz atmospheric windows centered at roughly 1.3 and 1.5~THz, contain
numerous spectral lines of astronomical importance, including three high-J CO
lines, the N+ line at 205 microns, and the ground transition of para-H2D+. The
CO lines are tracers of hot (several 100K), dense gas; N+ is a cooling line of
diffuse, ionized gas; the H2D+ line is a non-depleting tracer of cold (~20K),
dense gas. As the THz lines benefit the study of diverse phenomena (from
high-mass star-forming regions to the WIM to cold prestellar cores), we have
built the CO N+ Deuterium Observations Receiver (CONDOR) to further explore the
THz windows by ground-based observations. CONDOR was designed to be used at the
Atacama Pathfinder EXperiment (APEX) and Stratospheric Observatory For Infrared
Astronomy (SOFIA). CONDOR was installed at the APEX telescope and test
observations were made to characterize the instrument. The combination of
CONDOR on APEX successfully detected THz radiation from astronomical sources.
CONDOR operated with typical Trec=1600K and spectral Allan variance times of
30s. CONDOR's first light observations of CO 13-12 emission from the hot core
Orion FIR4 (= OMC1 South) revealed a narrow line with T(MB) = 210K and
delta(V)=5.4km/s. A search for N+ emission from the ionization front of the
Orion Bar resulted in a non-detection. The successful deployment of CONDOR at
APEX demonstrates the potential for making observations at THz frequencies from
ground-based facilities.Comment: 4 pages + list of objects, 3 figures, to be published in A&A special
APEX issu
G331.512-0.103:An Interstellar Laboratory for Molecular Synthesis. I. the Ortho-to-para Ratios for CH<sub>3</sub>OH and CH<sub>3</sub>CN
Spectral line surveys reveal rich molecular reservoirs in G331.512-0.103, a
compact radio source in the center of an energetic molecular outflow. In this
first work, we analyse the physical conditions of the source by means of
CHOH and CHCN. The observations were performed with the APEX telescope.
Six different system configurations were defined to cover most of the band
within (292-356) GHz; as a consequence we detected a forest of lines towards
the central core. A total of 70 lines of -CHOH and -CHCN were
analysed, including torsionally excited transitions of CHOH (=1). In
a search for all the isotopologues, we identified transitions of
CHOH. The physical conditions were derived considering collisional
and radiative processes. We found common temperatures for each and
symmetry of CHOH and CHCN; the derived column densities indicate an
equilibrated ratio for both tracers. The results reveal that CHCN and
CHOH trace a hot and cold component with 141 K and 74
K, respectively. In agreement with previous ALMA observations, the models show
that the emission region is compact ( 5.5 arcsec) with gas density
(H)=(0.7-1) 10 cm. The CHOH/CHCN abundance
ratio and the evidences for pre-biotic and complex organic molecules suggest a
rich and active chemistry towards G331.512-0.103.Comment: 15 pages, 7 figures, 7 tables. Accepted for publication in The
Astrophysical Journa
Scedosporium apiospermum as a rare cause of central skull base osteomyelitis.
We report a case of Scedosporium apiospermum mold causing ear infection, central skull base osteomyelitis and finally, occlusion of carotid artery in a 48-year-old diabetic man. The exact diagnosis was established and the severity of the disease understood several months after the onset of symptoms. Despite of appropriate antifungal therapy, and repeated surgical and otological procedures, the infection progressed to fatal cerebral infarction
- …