57 research outputs found

    Tailing Dam Zelazny Most Environmental Hazard

    Get PDF
    The factors governing the geotechnical stability of copper tailing dam Żelazny Most, the largest in Europe, have been discussed. The efficiency of pumping wells barrier against outflow of contaminated ground water has been predicted for a period of next 15 years

    Identification of the state of consistency in loosely cohesive soils based on penetration characteristics from cone penetration test

    No full text
    W pracy przedstawiono procedurę identyfikacji stanu konsystencji gruntów mało spoistych na podstawie parametrów penetracji z badania sondowania statycznego. Wskazano na czynniki, których pominięcie w analizie prowadzić może do błędnej interpretacji wyników badania. Zaproponowano postać związku empirycznego umożliwiającego oszacowanie stopnia plastyczności gruntów mało spoistych na podstawie znormalizowanego oporu stożka, przez uwzględnienie czynników zewnętrznych. Wiarygodność związku korelacyjnego zweryfikowano na podstawie wyników badań laboratoryjnych.The paper presents a procedure for the identification of the state of consistency for loosely cohesive soils based on penetration parameters from cone penetration tests. Factors were indicated, which elimination from the analysis may lead to an erroneous interpretation of testing results. A form was proposed for an empirical relationship facilitating estimation of the liquidity index for loosely cohesive soils based on cone resistance normalized by incorporation of the effect of external factors. Reliability of the correlation relationship was verified based on laboratory testing results

    Pore water pressure measurement using cone penetration test in terms of soil strength assessment

    No full text
    Obecnie metoda sondowania statycznego posiada już na tyle ugruntowaną pozycję wśród badań geotechnicznych, że często wskazywana jest jako badanie wiodące. Bywa niekiedy, że odwołując się do statusu badania, nadinterpretowuje się jego wyniki, szczególnie w sytuacji gdy dokonuje się oceny wytrzymałościowej podłoża jedynie na podstawie wyników testu CPT. W warunkach badania z odpływem wody i nośnego podłoża problem jest nieistotny, natomiast nabiera znaczenia, gdy w warunkach ograniczonego odpływu wody lub jego braku w ocenie wytrzymałościowej podłoża nie uwzględnia się rejestracji nadwyżki ciśnienia wody w porach. Kwestia wyboru wiarygodnej procedury interpretacyjnej stanowi kluczowy element we właściwej analizie wyników badania statycznego sondowania. W pracy przedstawiono ograniczenia i kryteria różnicujące wybór procedury interpretacyjnej do oceny parametrów wytrzymałości na ścinanie oraz porównano wyniki analizy wytrzymałościowej gruntów podłoża w zależności od rodzaju wykonanego badania CPT i CPTU.At present cone penetration test is considered to be a well-established method in geotechnical analyses to the point when it is frequently seen as a leading method. Sometimes its results are overestimated due to the status of this method, particularly when soil strength is evaluated solely on the basis of CPT results. At full drainage and a load-bearing subsoil this problem is not signifi cant, but it gains in importance when recorded excess pore water pressure is not included in the evaluation of soil strength under partial drainage or no drainage. The matter of selecting a reliable interpretation procedure constitutes a key element in the proper analysis of cone penetration test results. The paper presents limitations and criteria differentiating the selection of an interpretation procedure for the evaluation of shear strength parameters and a comparison of strength analyses results of soils depending on the type of applied CPT and CPTU

    Cone penetration test in assessment of soil stiffness

    No full text
    The paper presents proposals for the assessment of subsoil stiffness based on results of the seismic cone penetration test. Correlations between penetration parameters and constrained modulus were determined for three genetically different groups of cohesive soils. For the analyzed soil material quantitative estimation was also conducted for the parameter, which determines the relationship between the constrained modulus and initial shear modulus. A marked trend was shown for this parameter with the soil behavior type index used in the classification of soils in the cone penetration test

    Influence of fortified and defensive constructions on subsoil conditions in the surroundings of these facilities

    No full text
    Mury obronne, fosy stanowiące fortyfikacje dawnych obiektów historycznych, ale także podziemne bunkry i sztolnie budowane już w czasach współczesnych stanowią elementy infrastruktury, które pominięte w analizie warunków posadowienia nowo projektowanych obiektów skutkować mogą istotnymi błędami na etapie projektowania i wykonawstwa tych obiektów. Sama obecność konstrukcji fortyfikacyjnych z reguły uwzględniana jest na każdym etapie realizacji inwestycji, niekiedy jednak pomijane są uwarunkowania geotechniczne będące skutkiem przekształcenia terenu w otoczeniu budowli fortyfikacyjnych. W niniejszej pracy przedstawiono wpływ nieuwzględnienia w rozpoznaniu geotechnicznym bliskiego sąsiedztwa zamku w miejscowości Kórnik na warunki posadowienia pomostu w pobliskim jeziorze. Wskazano na powody nadmiernych osiadań podpór palowych oraz przedstawiono sposób naprawy zaistniałej sytuacji.Defensive walls, moats representing the fortifications of old historic buildings as well as underground bunkers and bombs adits already in modern times are the elements of infrastructure, which omitted in the analysis of foundation conditions of the newly designed objects may result in significant errors during the design stage and execution of theese facilities. The very presence of fortified constructions is usually taken into consideration at every stage of the investment execution, however sometimes the geotechnical conditions resulting from the transformation of the area in the surroundings of fortified buildings are overlooked. At this work an influence of the failure to consider was described in geotechnical recognition the close neighbourhood of the castle in the town Kórnik on the foundation conditions of the pier in the nearby lake. The reasons of excessive settlements of piles supports were indicated and a manner to correct the occured situation was presented

    Möglichkeiten der Palliativtherapie

    No full text
    corecore