90 research outputs found

    Case Report Successful Stent Graft Insertion for Endovascular Aneurysm Repair and Closure of Patent Ductus Arteriosus in an Adult Patient

    Get PDF
    Patent ductus arteriosus (PDA) is sometimes undetected until adulthood, and surgical closure of a PDA is dangerous because of the calcification of the ductus. Percutaneous approaches such as coil embolization and use of a PDA occluder are less invasive; however, these devices are not suitable for PDA with thoracic aortic aneurysm (TAA). We present the case of a 72-year-old female patient who underwent successful stent graft insertions for PDA with TAA

    Characteristics and in-hospital mortality of patients with COVID-19 from the first to fifth waves of the pandemic in 2020 and 2021 in the Japanese Medical Data Vision database

    Get PDF
    Objectives We aimed to describe patient characteristics, healthcare utilization, and in-hospital mortality among patients with COVID-19 in Japan across waves. Methods Using a large-scale hospital-based database, we identified patients hospitalized for COVID-19 in the first (January–June 2020), second (June–October 2020), third (October 2020–February 2021), fourth (March–June 2021), and fifth (June–December 2021) waves. We summarized patient characteristics, healthcare utilization, and in-hospital mortality during each wave and performed multivariable logistic regression analyses for in-hospital mortality. Results From the first to fifth waves, the number of patients (mean age ± standard deviation, years) was 2958 (61.2 ± 22.8), 7981 (55.6 ± 25.3), 18,788 (63.6 ± 22.9), 17,729 (60.6 ± 22.6), and 23,656 (51.2 ± 22.3), respectively. There were 190 (6.4%), 363 (4.5%), 1261 (6.7%), 1081 (6.1%), and 762 (3.2%) in-hospital deaths, respectively. The adjusted odds ratios for in-hospital deaths (95% confidence interval) were 0.78 (0.65–0.95), 0.94 (0.79–1.12), 0.99 (0.84–1.18), 0.77 (0.65–0.92), in the second to fifth waves, respectively, compared with the first wave. Conclusions In-hospital COVID-19 mortality improved from the first to the second wave; however, during the third and fourth waves, mortality was as serious as in the first wave. Although in-hospital mortality during the fifth wave improved, careful monitoring is needed for upcoming waves, considering changing patient and viral characteristics

    Successful Stent Graft Insertion for Endovascular Aneurysm Repair and Closure of Patent Ductus Arteriosus in an Adult Patient

    Get PDF
    Patent ductus arteriosus (PDA) is sometimes undetected until adulthood, and surgical closure of a PDA is dangerous because of the calcification of the ductus. Percutaneous approaches such as coil embolization and use of a PDA occluder are less invasive; however, these devices are not suitable for PDA with thoracic aortic aneurysm (TAA). We present the case of a 72-year-old female patient who underwent successful stent graft insertions for PDA with TAA

    Percutaneous Coronary Intervention for the Anomalous Left Coronary Artery Originating from the Noncoronary Cusp

    No full text
    Percutaneous coronary intervention (PCI) for anomalous left coronary artery (LCA) originating from the noncoronary cusp (NCC) is challenging, as it poses difficulties with the engagement of the guiding catheter and the establishment of backup support. This report examines the case of a 69-year-old woman with unstable angina of anomalous LCA origin. The computed tomography showed a diffuse plaque in the middle of the left anterior descending (LAD) artery and an anomalous LCA originating from the NCC. After successful engagement of a straightened Judkins-Left diagnostic catheter, the angiography revealed a diffuse plaque in the middle of the LAD artery. We then engaged a Judkins-Right guiding catheter. Due to the weak backup support of the guiding catheter, we used another wire to stabilize it, and the stent was then implanted successfully. To our knowledge, this is the first case report of PCI for an anomalous LCA originating from the NCC

    Outcomes of Robotic Coronary Artery Bypass Versus Nonrobotic Coronary Artery Bypass

    No full text
    BACKGROUND: Robotic coronary artery bypass graft (CABG) has developed in recent decades, however, prior studies showed conflicting result of robotic CABG compared to nonrobotic CABG in terms of mortality, morbidity, and cost. Herein, we sought to analyze the in-hospital outcomes and health care utilization after robotic CABG compared to nonrobotic CABG, based on data from a nationally representative sample. METHODS: Patients who underwent CABG were identified using the national inpatient sample. Endpoints were in-hospital outcomes, length of stay, and total cost. Procedure-related complications were identified via international classification of diseases (ICD)-9 and ICD-10 coding and propensity score matching analysis was performed. RESULTS: A total of 1,204,125 weighted adults underwent nonrobotic CABG and 7355 underwent robotic CABG in the United States between 2012 and 2017. The comparison of 7330 pairs after propensity score matching showed that in-hospital mortality was higher for those who underwent nonrobotic CABG compared to those who underwent robotic CABG (2.1% vs. 1.1%, p = .029). Similarly, the rates of acute kidney injury, transfusion, postoperative hemorrhage, length of stay, and total cost were higher for nonrobotic CABG compared to robotic CABG (all p \u3c .05). The proportions of routine discharges with (34.5% vs. 40.0%) or without (39.7% vs. 45.0%) home health care were higher among those who underwent robotic, whereas the proportion of transfer to skilled nursing facility/nursing home was more frequent for cases of nonrobotic CABG (22.4% vs. 13.4%). CONCLUSION: Robotic CABG was associated with lower rates of in-hospital mortality, acute kidney injury, transfusion, postoperative hemorrhage, total cost, and shorter hospital stay compared to nonrobotic CABG
    corecore