22 research outputs found

    Individualización del tratamiento con acenocumarol: desarrollo de nuevos algoritmos farmacogenéticos y su validación en enfermedad tromboembólica venosa

    Full text link
    Tesis doctoral inédita leída en la Universidad Autónoma de Madrid, Facultad de Medicina, Departamento de Cirugía. Fecha de lectura: 24-01-202

    Cardiovascular outcomes and hospitalizations in Asian patients receiving immune checkpoint inhibitors: a population-based study.

    Get PDF
    Immune checkpoint inhibitors (ICI) have known associations with cardiotoxicity. However, a representative quantification of the adverse cardiovascular events and cardiovascular attendances amongst Asian users of ICI has been lacking. This retrospective cohort study identified all ICI users in Hong Kong, China, between 2013-2021. All patients were followed up until the end of 2021 for the primary outcome of major adverse cardiovascular event (MACE; a composite of cardiovascular mortality, myocardial infarction, heart failure, and stroke). Patients with prior diagnosis of any component of MACE were excluded from all MACE analyses. In total, 4324 patients were analysed (2905 (67.2%) males; median age 63.5 years old (interquartile range 55.4-70.7 years old); median follow-up 1.0 year (interquartile range 0.4-2.3 years)), of whom 153 were excluded from MACE analyses due to prior events. MACE occurred in 116 (2.8%) with an incidence rate (IR) of 1.7 [95% confidence interval: 1.4, 2.0] events per 100 patient-years; IR was higher within the first year of follow-up (2.9 [2.3, 3.5] events per 100 patient-years). Cardiovascular hospitalization(s) occurred in 188 (4.4%) with 254 episodes (0.5% of all episodes) and 1555 days of hospitalization (1.3% of all hospitalized days), for whom the IR of cardiovascular hospitalization was 5.6 [4.6, 6.9] episodes per 100 person-years with 52.9 [39.8, 70.3] days' stay per 100 person-years. Amongst Asian users of ICI, MACE was uncommon, and a small proportion of hospitalizations was cardiovascular in nature. Most MACE and cardiovascular hospitalizations occurred during the first year after initiating ICI. [Abstract copyright: Copyright © 2022. Published by Elsevier Inc.

    Sulfonylurea is associated with higher risks of ventricular arrhythmia or sudden cardiac death compared with metformin: A population-based cohort study

    Get PDF
    Background Commonly prescribed diabetic medications such as metformin and sulfonylurea may be associated with different arrhythmogenic risks. This study compared the risk of ventricular arrhythmia or sudden cardiac death between metformin and sulfonylurea users in patients with type 2 diabetes. Methods and Results Patients aged ≥40 years who were diagnosed with type 2 diabetes or prescribed antidiabetic agents in Hong Kong between January 1, 2009, and December 31, 2009, were included and followed up until December 31, 2019. Patients prescribed with both metformin and sulfonylurea or had prior myocardial infarction were excluded. The study outcome was a composite of ventricular arrhythmia or sudden cardiac death. Metformin users and sulfonylurea users were matched at a 1:1 ratio by propensity score matching. The matched cohort consisted of 16 596 metformin users (47.70% men; age, 68±11 years; mean follow‐up, 4.92±2.55 years) and 16 596 sulfonylurea users (49.80% men; age, 70±11 years; mean follow‐up, 4.93±2.55 years). Sulfonylurea was associated with higher risk of ventricular arrhythmia or sudden cardiac death than metformin hazard ratio (HR, 1.90 [95% CI, 1.73–2.08]). Such difference was consistently observed in subgroup analyses stratifying for insulin usage or known coronary heart disease. Conclusions Sulfonylurea use is associated with higher risk of ventricular arrhythmia or sudden cardiac death than metformin in patients with type 2 diabetes

    Eficacia de una vía de alta resolución en la evaluación del cólico renoureteral no complicado en un servicio de urgencias hospitalario: un ensayo clínico aleatorizado (Estudio STONE).

    Get PDF
    Objetivo. Evaluar una vía de alta resolución (vía POC) que utiliza análisis en el punto de atención (point-of-care testing –POCT–) y ecografía en el punto de atención (point-of-care ultrasonography –POCUS–) en la sospecha del cólico renoureteral (CRU) no complicado y compararla con la vía estándar (vía STD). Método. Ensayo clínico aleatorizado, controlado, no ciego, realizado en un servicio de urgencias hospitalario (SUH). Incluyó pacientes con sospecha clínica de CRU agudo y se aleatorizaron 1:1 a seguir vía POC o vía STD. Se analizó el tiempo de estancia en el SUH, el tratamiento administrado, la proporción de diagnósticos alternativos a CRU y las complicaciones a 30 días. Resultados. Entre noviembre de 2018 y octubre de 2019, se reclutaron 140 pacientes de los que se analizaron 124. El tiempo de estancia total en el SUH de la vía POC fue de 112 minutos (DE 45) y en la vía STD 244 minutos (DE 102) (p < 0,001). No hubo diferencias en el tratamiento administrado en urgencias, en el número de diagnósticos alternativos, ni en las complicaciones a 30 días. Conclusiones. La utilización de una vía de alta resolución del manejo del CRU en un SUH es eficaz, segura y reduce el tiempo de estancia en urgencias.post-print225 K

    Cardiovascular outcomes and hospitalizations in Asian patients receiving immune checkpoint inhibitors: A population-based study

    Get PDF
    Immune checkpoint inhibitors (ICI) have known associations with cardiotoxicity. However, a representative quantification of the adverse cardiovascular events and cardiovascular attendances amongst Asian users of ICI has been lacking. This retrospective cohort study identified all ICI users in Hong Kong, China, between 2013 and 2021. All patients were followed up until the end of 2021 for the primary outcome of major adverse cardiovascular event (MACE; a composite of cardiovascular mortality, myocardial infarction, heart failure, and stroke). Patients with prior diagnosis of any component of MACE were excluded from all MACE analyses. In total, 4324 patients were analyzed (2905 (67.2%) males; median age 63.5 years old (interquartile range 55.4-70.7 years old); median follow-up 1.0 year (interquartile range 0.4-2.3 years)), of whom 153 were excluded from MACE analyses due to prior events. MACE occurred in 116 (2.8%) with an incidence rate (IR) of 1.7 [95% confidence interval: 1.4, 2.0] events per 100 patient-years; IR was higher within the first year of follow-up (2.9 [2.3, 3.5] events per 100 patient-years). Cardiovascular hospitalization(s) occurred in 188 (4.4%) with 254 episodes (0.5% of all episodes) and 1555 days of hospitalization (1.3% of all hospitalized days), for whom the IR of cardiovascular hospitalization was 5.6 [4.6, 6.9] episodes per 100 person-years with 52.9 [39.8, 70.3] days’ stay per 100 person-years. Amongst Asian users of ICI, MACE was uncommon, and a small proportion of hospitalizations were cardiovascular in nature. Most MACE and cardiovascular hospitalizations occurred during the first year after initiating ICI

    Acenocoumarol Pharmacogenetic Dosing Algorithm versus Usual Care in Patients with Venous Thromboembolism: A Randomised Clinical Trial

    Get PDF
    Patients with venous thromboembolism (VTE) require immediate treatment with anticoagulants such as acenocoumarol. This multicentre randomised clinical trial evaluated the effectiveness of a dosing pharmacogenetic algorithm versus a standard-of-care dose adjustment at the beginning of acenocoumarol treatment. We included 144 patients with VTE. On the day of recruitment, a blood sample was obtained for genotyping (CYP2C9*2, CYP2C9*3, VKORC1, CYP4F2, APOE). Dose adjustment was performed on day 3 or 4 after the start of treatment according to the assigned group and the follow-up was at 12 weeks. The principal variable was the percentage of patients with an international normalised ratio (INR) within the therapeutic range on day 7. Thirty-four (47.2%) patients had an INR within the therapeutic range at day 7 after the start of treatment in the genotype-guided group compared with 14 (21.9%) in the control group (p = 0.0023). There were no significant differences in the time to achieve a stable INR, the number of INRs within the range in the first 6 weeks and at the end of study. Our results suggest the use of a pharmacogenetic algorithm for patients with VTE could be useful in achieving target INR control in the first days of treatment

    World Congress Integrative Medicine & Health 2017: Part one

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Chromatographic profiling and multivariate analysis for screening and quantifying the contributions from individual components to the bioactive signature in natural products

    No full text
    A new approach for assigning bioactivity to individual components in extracts from natural products is presented and validated. 60 mixtures were created according to a uniform design from 12 chemical components of which 7 possessed antioxidant activity. The synthetic mixtures were characterized by chromatographic profiling and their antioxidant power was assessed by use of the Ferric Reducing Antioxidant Power (FRAP) assay. 40 of the prepared mixtures were used as a training set to create a cross validated partial least squares (PLS) regression model with the FRAP measurement as response. The remaining 20 mixtures were used as an independent external validation set. The bioactive signature was singled out from the multi-component PLS model using target projection (TP). In addition to excellent prediction performance of antioxidant strength from the bioactive signature, our approach, called Quantitative Pattern-Activity Relationship (QPAR), was able to rank 6 of the 7 bioactive components according to individual bioactive strength. The ratios of bioactive capacity of the two most active components to the two least active components were close to 100 to 1. This explains why one of the two least bioactive components was not detected
    corecore