6 research outputs found
Urinary Glycosaminoglycan Electrophoresis With Optimized Keratan Sulfate Separation Using Peltier System for the Screening of Mucopolysaccharidoses
The purpose of this communication is to indicate a simple and rapid method with a small volume of urine sample to detect urine glycosaminoglycan (GAG) and serve as a screening procedure for mucopolysaccharidoses (MPSs). Total GAG measurement for patients with MPS disorders is considered to be the first step in diagnosis of those heterogeneous group of lysosomal storage disorders presenting clinical phenotype. In this study, modified 9-dimethylmethylene blue method is used for total GAG measurement. Following GAG quantitation, the procedure described here allows GAG isolation from a very a small volume of urine sample and subjected to high-resolution GAG electrophoresis, which can be easily performed in routine clinical diagnostic laboratories. Glycosaminoglycan precipitation is a modified method based on total GAG concentration in the urine. For optimized isolation of total GAG for electrophoresis, instead of considering the urine creatinine concentration, 300 μg/mL GAG containing urine is considered to be the target concentration for the best precipitation with 1000 μL cetylpyridinium chloride (CPC)/citrate buffer. Glycosaminoglycan concentration-based precipitation of urine with CPC allows the laboratory to be able to work with a small volume of urine sample by keeping the precipitating ratio with CPC constant for samples that contain GAG less than 300 μg/mL. Based on the effect of cold buffer using low voltage, GAGs high-resolution electrophoresis banding patterns described here enable a clear separation of keratan sulfate from chondroitin sulfate as well as dermatan sulfate (DS1 and DS2) and heparan sulfate. By this procedure, GAG patterns are more clear, easily identified, and provide a guide for the enzyme analysis deficient in the MPS disorders
Does tibolone affect serum leptin levels and body weight in postmenopausal women?
Objectives: Leptin has a significant role in body weight regulation and energy balance. We examined the effect of tibolone on the body weight and serum leptin levels in postmenopausal women. Study design: Twenty women (aged 43-60 years) participated in this prospective study. All women in this study protocol received 2.5 mg/day of tibolone. Absolute and body mass index (BMI)-corrected serum leptin concentrations and BMI values were measured at baseline, after 3 months, and after 6 months of the tibolone therapy. Results: Tibolone did not affect absolute and BMI-corrected serum leptin levels, and BMI values during the treatment. A significant linear correlation between BMI values and serum leptin levels was observed (p<0.05, r=0.67). Conclusions: Tibolone seems not to affect serum leptin levels, body weight and BMI values of postmenopausal women. There is a significant correlation between serum leptin levels and BMI values. © Springer-Verlag 2004
Enhanced interpretation of newborn screening results without analyte cutoff values
A collaboration among 157 newborn screening programs in 47 countries has lead to the
creation of a database of 705,333 discrete analyte concentrations from 11,462 cases affected with
57 metabolic disorders, and from 631 heterozygotes for 12 conditions. This evidence was first
applied to establish disease ranges for amino acids and acylcarnitines, and clinically validate 114
cutoff target ranges.
Objective: To improve quality and performance with an evidence-based approach, multivariate
pattern recognition software has been developed to aid in the interpretation of complex analyte
profiles. The software generates tools that convert multiple clinically significant results into a
single numerical score based on overlap between normal and disease ranges, penetration within
the disease range, differences between specific conditions, and weighted correction factors.
Design: Eighty-five on-line tools target either a single condition or the differential diagnosis
between two or more conditions. Scores are expressed as a numerical value and as the percentile
rank among all cases with the condition chosen as primary target, and are compared to
interpretation guidelines. Tools are updated automatically after any new data submission (2009-
2011: 5.2 new cases added per day on average).
Main outcome measures: Retrospective evaluation of past cases suggest that these tools could
have avoided at least half of 277 false positive outcomes caused by carrier status for fatty acid
oxidation disorders, and could have prevented 88% of false negative events caused by cutoff
7
values set inappropriately. In Minnesota, their prospective application has been a major
contributing factor to the sustained achievement of a false positive rate below 0.1% and a
positive predictive value above 60%.
Conclusions: Application of this computational approach to raw data could make cutoff values
for single analytes effectively obsolete. This paradigm is not limited to newborn screening and is
applicable to the interpretation of diverse multi-analyte profiles utilized in laboratory medicine.
Abstract wor
Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: A worldwide collaborative project
PURPOSE:: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. METHODS:: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742 deidentified true positive cases are compared to assign clinical significance, which is achieved when the median of a disorder range is, and usually markedly outside, either the 99th or the 1st percentile of the normal population. The cutoff target ranges of analytes and ratios are then defined as the interval between selected percentiles of the two populations. When overlaps occur, adjustments are made to maximize sensitivity and specificity taking all available factors into consideration. RESULTS:: As of December 1, 2010, 130 sites in 45 countries have uploaded a total of 25,114 percentile data points, 565,232 analyte results of true positive cases with 64 conditions, and 5,341 cutoff values. The average rate of submission of true positive cases between December 1, 2008, and December 1, 2010, was 5.1 cases/day. This cumulative evidence generated 91 high and 23 low cutoff target ranges. The overall proportion of cutoff values within the respective target range was 42% (2,269/5,341). CONCLUSION:: An unprecedented level of cooperation and collaboration has allowed the objective definition of cutoff target ranges for 114 markers to be applied to newborn screening of rare metabolic disorders. © 2011 Lippincott Williams & Wilkins