598 research outputs found
Recommended from our members
H I 21-cm Cosmology and the Bispectrum: Closure Diagnostics in Massively Redundant Interferometric Arrays
New massively redundant low frequency arrays allow for a novel investigation
of closure relations in interferometry. We employ commissioning data from the
Hydrogen Epoch of Reionization Array to investigate closure quantities in this
densely packed grid array of 14m antennas operating at 100 MHz to 200 MHz. We
investigate techniques that utilize closure phase spectra for redundant triads
to estimate departures from redundancy for redundant baseline visibilities. We
find a median absolute deviation from redundancy in closure phase across the
observed frequency range of about 4.5deg. This value translates into a
non-redundancy per visibility phase of about 2.6deg, using prototype
electronics. The median absolute deviations from redundancy decrease with
longer baselines. We show that closure phase spectra can be used to identify
ill-behaved antennas in the array, independent of calibration. We investigate
the temporal behavior of closure spectra. The Allan variance increases after a
one minute stride time, due to passage of the sky through the primary beam of
the transit telescope. However, the closure spectra repeat to well within the
noise per measurement at corresponding local sidereal times (LST) from day to
day. In future papers in this series we will develop the technique of using
closure phase spectra in the search for the HI 21cm signal from cosmic
reionization
Removal of turbidity from washing machine discharge using Strychnos potatorum seeds: Parameter optimization and mechanism prediction
In this research an attempt has been made to utilize the Strychnos potatorum seed powder as an environmentally friendly coagulant for the removal of turbidity from washing machine discharge. The performance of this system was also compared with synthetic water. Experimental studies were conducted for the maximum removal of turbidity from washing machine discharge and synthetic turbid water which were varied from 50 to 145 NTU. The effect of operating parameters such as initial turbidity, S. potatorum dosage and pH of the solution was optimized for the maximum removal of turbidity. It was seen that the percentage removal of turbidity lay was between 68-89% and 65-84% for synthetic turbid water and washing machine discharge sample respectively, at an ideal pH of 6-7. The experimental values were compared with the Langmuir and Freundlich isotherm models to understand the extent of influence of the sorption of the particles onto the S. potatorum seed powder. Better results with respect to concordance of experimental data were observed with Langmuir isotherm model, indicating a monolayer sorption of particles onto the S. potatorum seed powder. It was observed from the isotherm study that the sorption may also be influenced in the removal of turbidity to some extent from the washing machine discharge and synthetic water. The prepared material can be effectively utilized for the removal of turbidity from the water
Evaluation of a Cold Staining Method for Acid-Fast Bacilli in Sputum
Comparison between the Ziehl-Neelscn staining method for acid-fast bacilli, applied with and
without heating, was carried out in a controlled investigation using smears prepared from 306
sputum samples collected prior to treatment from suspected cases of pulmonary tuberculosis.
Smear and culture positively were graded and the colour intensity of bacilli recorded. Results
showed that the chance corrected agreement (Kappa) between Z-N and cold methods was only
78%. The sensitivity of the Z-N and cold methods were 84% and 77% respectively when
compared with culture results. Assuming 10% smear positivity among symptomatics reporting to
Peripheral Health Institutions (PHIs), the positive predictive value of the cold method was very
low(53%). When compared to culture, the positive predictive value is 71% for the Z-N method
and 57% for the cold method for a symptomatic population with 15% culture positivity.
In the absence of heating. penetration of the stain was significantly reduced and consequently
the number of bacilli detected was less. The inability to take the stain without heating was seen in
smears from all grades of culture positive samples: thus even heavy positives were missed by the
cold method. The evaluation of the cold method against the standard Z-N method highlights its
limitations and demonstrates that it is not as reliable as the standard Z-N method
Sputum conversion at the end of intensive phase of Category-1 regimen in the treatment of pulmonary tuberculosis patients with diabetes mellitus or HIV infection: An analysis of risk factors
Background & objectives: New smear-positive pulmonary tuberculosis (PTB) patients in the Revised
National Tuberculosis Control Programme (RNTCP) are treated with a 6-month short-course
chemotherapy (SCC) regimen irrespective of co-morbid conditions. We undertook this retrospective
analysis to compare sputum conversion rates (smear, culture) at the end of intensive phase (IP) of
Category-1 regimen among patients admitted to concurrent controlled clinical trials: pulmonary
tuberculosis alone (PTB) or with type 2 diabetes mellitus (DM-TB) or HIV infection (HIV-TB), and
to identify the risk factors influencing sputum conversion.
Methods: In this retrospective analysis sputum conversion rates at the end of intensive phase (IP) in
three concurrent studies undertaken among PTB, DM-TB and HIV-TB patients, during 1998 –
2002 at the Tuberculosis Research Centre (TRC), Chennai, were compared. Sputum smears were
examined by fluorescent microscopy. HIV infected patients did not receive anti-retroviral treatment
(ART). Patients with DM were treated with oral hypoglycaemic drugs or insulin (sc).
Results: The study population included 98, 92 and 88 patients in the PTB, DM-TB and HIV-TB
studies. At the end of IP the smear conversion (58, 61, and 62%) and culture conversion (86, 88 and
92%) rates were similar in the three groups respectively. The variables associated with lack of
sputum smear or culture conversion were age >45 yr, higher pre-treatment smear and culture grading,
and extent of the radiographic involvement.
Interpretation & conclusions: Our findings confirm that the current policy of the control programme
to treat all pulmonary TB patients with or with out co-morbid conditions with Category-I regimen
appears to be appropriate
Searching for gravitational wave bursts from cosmic string cusps with the Parkes Pulsar Timing Array
Cosmic strings are potential gravitational wave (GW) sources that can be
probed by pulsar timing arrays (PTAs). In this work we develop a detection
algorithm for a GW burst from a cusp on a cosmic string, and apply it to Parkes
PTA data. We find four events with a false alarm probability less than 1%.
However further investigation shows that all of these are likely to be
spurious. As there are no convincing detections we place upper limits on the GW
amplitude for different event durations. From these bounds we place limits on
the cosmic string tension of G mu ~ 10^{-5}, and highlight that this bound is
independent from those obtained using other techniques. We discuss the physical
implications of our results and the prospect of probing cosmic strings in the
era of Square Kilometre Array (SKA).Comment: Accepted for publication by MNRA
Recommended from our members
The APOE ε4 allele is associated with a reduction in FEV1/FVC in women: A cross-sectional analysis of the Long Life Family Study
Introduction
Murine studies have shown that apolipoprotein E modulates pulmonary function during development, aging, and allergen-induced airway disease. It is not known whether the polymorphic human APOE gene influences pulmonary function.
Objectives
We assessed whether an association exists between the polymorphic human APOE ε2, ε3, and ε4 alleles and pulmonary function among participants in the Long Life Family Study.
Methods
Data from 4,468 Caucasian subjects who had genotyping performed for the APOE ε2, ε3, and ε4 alleles were analyzed, with and without stratification by sex. Statistical models were fitted considering the effects of the ε2 allele, defined as ε2/2 or ε2/3 genotypes, and the ε4 allele, defined as ε3/4 or ε4/4 genotypes, which were compared to the ε3/3 genotype.
Results
The mean FEV1/FVC ratio (the forced expiratory volume in one second divided by the forced vital capacity) was lower among women with the ε4 allele as compared to women with the ε3/3 genotype or the ε2 allele. Carriage of the APOE ε4 allele was associated with FEV1/FVC, which implied lower values. Further analysis showed that the association primarily reflected women without lung disease who were older than 70 years. The association was not mediated by lipid levels, smoking status, body mass index, or cardiovascular disease.
Conclusions
This study for the first time identifies that the APOE gene is associated with modified lung physiology in women. This suggests that a link may exist between the APOE ε4 allele, female sex, and a reduction in the FEV1/FVC ratio in older individuals
The Hydrogen Epoch of Reionization Array Dish I: Beam Pattern Measurements and Science Implications
The Hydrogen Epoch of Reionization Array (HERA) is a radio interferometer
aiming to detect the power spectrum of 21 cm fluctuations from neutral hydrogen
from the Epoch of Reionization (EOR). Drawing on lessons from the Murchison
Widefield Array (MWA) and the Precision Array for Probing the Epoch of
Reionization (PAPER), HERA is a hexagonal array of large (14 m diameter) dishes
with suspended dipole feeds. Not only does the dish determine overall
sensitivity, it affects the observed frequency structure of foregrounds in the
interferometer. This is the first of a series of four papers characterizing the
frequency and angular response of the dish with simulations and measurements.
We focus in this paper on the angular response (i.e., power pattern), which
sets the relative weighting between sky regions of high and low delay, and
thus, apparent source frequency structure. We measure the angular response at
137 MHz using the ORBCOMM beam mapping system of Neben et al. We measure a
collecting area of 93 m^2 in the optimal dish/feed configuration, implying
HERA-320 should detect the EOR power spectrum at z~9 with a signal-to-noise
ratio of 12.7 using a foreground avoidance approach with a single season of
observations, and 74.3 using a foreground subtraction approach. Lastly we study
the impact of these beam measurements on the distribution of foregrounds in
Fourier space.Comment: 13 pages, 9 figures. Replaced to match accepted ApJ versio
- …