197 research outputs found

    Tunable control of CAR T cell activity through tetracycline mediated disruption of protein-protein interaction

    Get PDF
    Chimeric antigen receptor (CAR) T cells are a promising form of cancer immunotherapy, although they are often associated with severe toxicities. Here, we present a split-CAR design incorporating separate antigen recognition and intracellular signaling domains. These exploit the binding between the tetracycline repressor protein and a small peptide sequence (TIP) to spontaneously assemble as a functional CAR. Addition of the FDA-approved, small molecule antibiotic minocycline, acts as an "off-switch" by displacing the signaling domain and down-tuning CAR T activity. Here we describe the optimization of this split-CAR approach to generate a CAR in which cytotoxicity, cytokine secretion and proliferation can be inhibited in a dose-dependent and reversible manner. Inhibition is effective during on-going CAR T cell activation and inhibits activation and tumor control in vivo. This work shows how optimization of split-CAR structure affects function and adds a novel design allowing easy CAR inhibition through an FDA-approved small molecule

    The Use of a Mobile Laboratory Unit in Support of Patient Management and Epidemiological Surveillance during the 2005 Marburg Outbreak in Angola

    Get PDF
    A mobile laboratory unit (MLU) was deployed to Uige, Angola as part of the World Health Organization response to an outbreak of viral hemorrhagic fever caused by Marburg virus (MARV). Utilizing mainly quantitative real-time PCR assays, this laboratory provided specific MARV diagnostics in the field. The MLU operated for 88 consecutive days allowing MARV-specific diagnostic response in <4 hours from sample receiving. Most cases were found among females in the child-bearing age and in children less than five years of age including a high number of paediatric cases implicating breastfeeding as potential transmission route. Oral swabs were identified as a useful alternative specimen source to the standard whole blood/serum specimens for patients refusing blood draw. There was a high concordance in test results between the MLU and the reference laboratory in Luanda operated by the US Centers for Disease Control and Prevention. The MLU was an important outbreak response asset providing valuable support in patient management and epidemiological surveillance. Field laboratory capacity should be expanded and made an essential part of any future outbreak investigation

    Evaluation of the measurement properties of the Manchester foot pain and disability index

    Get PDF
    BACKGROUND: The Manchester Foot Pain and Disability Index (MFPDI, 19 items) was developed to measure functional limitations, pain and appearance for patients with foot pain and is frequently used in both observational studies and randomised controlled trials. A Dutch version of the MFPDI was developed. The aims of this study were to evaluate all the measurement properties for the Dutch version of the MFPDI and to evaluate comparability to the original version. METHOD: The MFPDI was translated into Dutch using a forward/backward translation process. The dimensionality was evaluated using exploratory and confirmatory factor analysis. Measurement properties were evaluated per subscale according to the COSMIN taxonomy consisting of: reliability (internal consistency, test-retest reliability and measurement error), validity (structural validity, content validity and cross-cultural validity comparing the Dutch version to the English version) responsiveness and interpretation. RESULTS: The questionnaire consists of three scales, measuring foot function, foot pain and perception. The reliability of the foot function scale is acceptable (Cronbach’s α > 0.7, ICC = 0.7, SEM = 2.2 on 0-18 scale). The construct validity of the function and pain scale was confirmed and only the pain scale contains one item with differential item functioning (DIF). The responsiveness of the function and pain scale is moderate when compared to anchor questions. CONCLUSION: Results using the Dutch MFPDI version can be compared to results using the original version. The foot function sub-scale (items 1-9) is a reliable and valid sub-scale. This study indicates that the use of the MFPDI as a longitudinal instrument might be problematic for measuring change in musculoskeletal foot pain due to moderate responsiveness

    Implications For The Origin Of GRB 051103 From LIGO Observations

    Get PDF
    We present the results of a LIGO search for gravitational waves (GWs) associated with GRB 051103, a short-duration hard-spectrum gamma-ray burst (GRB) whose electromagnetically determined sky position is coincident with the spiral galaxy M81, which is 3.6 Mpc from Earth. Possible progenitors for short-hard GRBs include compact object mergers and soft gamma repeater (SGR) giant flares. A merger progenitor would produce a characteristic GW signal that should be detectable at the distance of M81, while GW emission from an SGR is not expected to be detectable at that distance. We found no evidence of a GW signal associated with GRB 051103. Assuming weakly beamed gamma-ray emission with a jet semi-angle of 30 deg we exclude a binary neutron star merger in M81 as the progenitor with a confidence of 98%. Neutron star-black hole mergers are excluded with > 99% confidence. If the event occurred in M81 our findings support the the hypothesis that GRB 051103 was due to an SGR giant flare, making it the most distant extragalactic magnetar observed to date.Comment: 8 pages, 3 figures. For a repository of data used in the publication, go to: https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=15166 . Also see the announcement for this paper on ligo.org at: http://www.ligo.org/science/Publication-GRB051103/index.ph

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 102210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Sensitivity to Gravitational Waves from Compact Binary Coalescences Achieved during LIGO's Fifth and Virgo's First Science Run

    Get PDF
    We summarize the sensitivity achieved by the LIGO and Virgo gravitational wave detectors for compact binary coalescence (CBC) searches during LIGO's fifth science run and Virgo's first science run. We present noise spectral density curves for each of the four detectors that operated during these science runs which are representative of the typical performance achieved by the detectors for CBC searches. These spectra are intended for release to the public as a summary of detector performance for CBC searches during these science runs.Comment: 12 pages, 5 figure

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi
    corecore