362 research outputs found
Mass Transfer in a closed stirred gas/liquid contactor: Part 2: The liquid phase mass transfer coefficient kL
The liquid phase mass transfer coefficient kL for the absorption of oxygen in tap water and in ionic solutions has been calculated from the quotien\ud
\ud
It is concluded that the liquid phase mass transfer coefficient is roughly proportional to the stirrer speed. The gas fraction e apparently has littl
Mass Transfer in a closed stirred gas/liquid contactor: Part 1: The mass transfer rate kLS
Liquid phase mass transfer rates kLS for the absorption of oxygen in tap water and in aqueous ionic solutions have been determined in two closed stirred tank contactors for a power input between 3 and 70 W/kg and (impeller diameter)f(tank diameter) ratios DifT of 0.3, 0.35 and 0.4. The contactors had diameters\ud
of 0. I9 and 0.6 m. The dispersed phase fraction was 1% by volume in all experiments. The values of kLS were determined using two different techniques:\ud
(1) a transient physical absorption method; and (2) the sulphite method
Evaluation of absorption cycle for space station environmental control system application Interim report
Zero-gravity absorption refrigeration system design and performance testing for space station environmental control applicatio
- …