5 research outputs found

    Tuberculosis screening among HIV-positive inpatients: a systematic review and individual participant data meta-analysis

    Full text link
    Background: Since 2011, WHO has recommended that HIV-positive inpatients be routinely screened for tuberculosis with the WHO four-symptom screen (W4SS) and, if screened positive, receive a molecular WHO-recommended rapid diagnostic test (eg, Xpert MTB/RIF [Xpert] assay). To inform updated WHO tuberculosis screening guidelines, we conducted a systematic review and individual participant data meta-analysis to assess the performance of W4SS and alternative screening tests to guide Xpert testing and compare the diagnostic accuracy of the WHO Xpert algorithm (ie, W4SS followed by Xpert) with Xpert for all HIV-positive inpatients. Methods: We searched MEDLINE, Embase, and Cochrane Library from Jan 1, 2011, to March 1, 2020, for studies of adult and adolescent HIV-positive inpatients enrolled regardless of tuberculosis signs and symptoms. The separate reference standards were culture and Xpert. Xpert was selected since it is most likely to be the confirmatory test used in practice. We assessed the proportion of inpatients eligible for Xpert testing using the WHO algorithm; assessed the accuracy of W4SS and alternative screening tests or strategies to guide diagnostic testing; and compared the accuracy of the WHO Xpert algorithm (W4SS followed by Xpert) with Xpert for all. We obtained pooled proportion estimates with a random-effects model, assessed diagnostic accuracy by fitting random-effects bivariate models, and assessed diagnostic yield descriptively. This systematic review has been registered on PROSPERO (CRD42020155895). Findings: Of 6162 potentially eligible publications, six were eligible and we obtained data for all of the six publications (n=3660 participants). The pooled proportion of inpatients eligible for an Xpert was 90% (95% CI 89–91; n=3658). Among screening tests to guide diagnostic testing, W4SS and C-reactive protein (≥5 mg/L) had highest sensitivities (≥96%) but low specificities (≤12%); cough (≥2 weeks), haemoglobin concentration (<8 g/dL), body-mass index (<18·5 kg/m2), and lymphadenopathy had higher specificities (61–90%) but suboptimal sensitivities (12–57%). The WHO Xpert algorithm (W4SS followed by Xpert) had a sensitivity of 76% (95% CI 67–84) and specificity of 93% (88–96; n=637). Xpert for all had similar accuracy to the WHO Xpert algorithm: sensitivity was 78% (95% CI 69–85) and specificity was 93% (87–96; n=639). In two cohorts that had sputum and non-sputum samples collected for culture or Xpert, diagnostic yield of sputum Xpert was 41–70% and 61–64% for urine Xpert. Interpretation: The W4SS and other potential screening tests to guide Xpert testing have suboptimal accuracy in HIV-positive inpatients. On the basis of these findings, WHO now strongly recommends molecular rapid diagnostic testing in all medical HIV-positive inpatients in settings where tuberculosis prevalence is higher than 10%. Funding: World Health Organization

    Tuberculosis screening among ambulatory people living with HIV: a systematic review and individual participant data meta-analysis

    Get PDF
    BACKGROUND: The WHO-recommended tuberculosis screening and diagnostic algorithm in ambulatory people living with HIV is a four-symptom screen (known as the WHO-recommended four symptom screen [W4SS]) followed by a WHO-recommended molecular rapid diagnostic test (eg Xpert MTB/RIF [hereafter referred to as Xpert]) if W4SS is positive. To inform updated WHO guidelines, we aimed to assess the diagnostic accuracy of alternative screening tests and strategies for tuberculosis in this population. METHODS: In this systematic review and individual participant data meta-analysis, we updated a search of PubMed (MEDLINE), Embase, the Cochrane Library, and conference abstracts for publications from Jan 1, 2011, to March 12, 2018, done in a previous systematic review to include the period up to Aug 2, 2019. We screened the reference lists of identified pieces and contacted experts in the field. We included prospective cross-sectional, observational studies and randomised trials among adult and adolescent (age ≥10 years) ambulatory people living with HIV, irrespective of signs and symptoms of tuberculosis. We extracted study-level data using a standardised data extraction form, and we requested individual participant data from study authors. We aimed to compare the W4SS with alternative screening tests and strategies and the WHO-recommended algorithm (ie, W4SS followed by Xpert) with Xpert for all in terms of diagnostic accuracy (sensitivity and specificity), overall and in key subgroups (eg, by antiretroviral therapy [ART] status). The reference standard was culture. This study is registered with PROSPERO, CRD42020155895. FINDINGS: We identified 25 studies, and obtained data from 22 studies (including 15 666 participants; 4347 [27·7%] of 15 663 participants with data were on ART). W4SS sensitivity was 82% (95% CI 72-89) and specificity was 42% (29-57). C-reactive protein (≥10 mg/L) had similar sensitivity to (77% [61-88]), but higher specificity (74% [61-83]; n=3571) than, W4SS. Cough (lasting ≥2 weeks), haemoglobin (<10 g/dL), body-mass index (<18·5 kg/m2), and lymphadenopathy had high specificities (80-90%) but low sensitivities (29-43%). The WHO-recommended algorithm had a sensitivity of 58% (50-66) and a specificity of 99% (98-100); Xpert for all had a sensitivity of 68% (57-76) and a specificity of 99% (98-99). In the one study that assessed both, the sensitivity of sputum Xpert Ultra was higher than sputum Xpert (73% [62-81] vs 57% [47-67]) and specificities were similar (98% [96-98] vs 99% [98-100]). Among outpatients on ART (4309 [99·1%] of 4347 people on ART), W4SS sensitivity was 53% (35-71) and specificity was 71% (51-85). In this population, a parallel strategy (two tests done at the same time) of W4SS with any chest x-ray abnormality had higher sensitivity (89% [70-97]) and lower specificity (33% [17-54]; n=2670) than W4SS alone; at a tuberculosis prevalence of 5%, this strategy would require 379 more rapid diagnostic tests per 1000 people living with HIV than W4SS but detect 18 more tuberculosis cases. Among outpatients not on ART (11 160 [71·8%] of 15 541 outpatients), W4SS sensitivity was 85% (76-91) and specificity was 37% (25-51). C-reactive protein (≥10 mg/L) alone had a similar sensitivity to (83% [79-86]), but higher specificity (67% [60-73]; n=3187) than, W4SS and a sequential strategy (both test positive) of W4SS then C-reactive protein (≥5 mg/L) had a similar sensitivity to (84% [75-90]), but higher specificity than (64% [57-71]; n=3187), W4SS alone; at 10% tuberculosis prevalence, these strategies would require 272 and 244 fewer rapid diagnostic tests per 1000 people living with HIV than W4SS but miss two and one more tuberculosis cases, respectively. INTERPRETATION: C-reactive protein reduces the need for further rapid diagnostic tests without compromising sensitivity and has been included in the updated WHO tuberculosis screening guidelines. However, C-reactive protein data were scarce for outpatients on ART, necessitating future research regarding the utility of C-reactive protein in this group. Chest x-ray can be useful in outpatients on ART when combined with W4SS. The WHO-recommended algorithm has suboptimal sensitivity; Xpert for all offers slight sensitivity gains and would have major resource implications. FUNDING: World Health Organization

    Diagnostic yield of urine lipoarabinomannan and sputum tuberculosis tests in people living with HIV: a systematic review and meta-analysis of individual participant data

    No full text
    Background: Sputum is the most widely used sample to diagnose active tuberculosis, but many people living with HIV are unable to produce sputum. Urine, in contrast, is readily available. We hypothesised that sample availability influences the diagnostic yield of various tuberculosis tests. Methods: In this systematic review and meta-analysis of individual participant data, we compared the diagnostic yield of point-of-care urine-based lipoarabinomannan tests with that of sputum-based nucleic acid amplification tests (NAATs) and sputum smear microscopy (SSM). We used microbiologically confirmed tuberculosis based on positive culture or NAAT from any body site as the denominator and accounted for sample provision. We searched PubMed, Web of Science, Embase, African Journals Online, and clinicaltrials.gov from database inception to Feb 24, 2022 for randomised controlled trials, cross-sectional studies, and cohort studies that assessed urine lipoarabinomannan point-of-care tests and sputum NAATs for active tuberculosis detection in participants irrespective of tuberculosis symptoms, HIV status, CD4 cell count, or study setting. We excluded studies in which recruitment was not consecutive, systematic, or random; provision of sputum or urine was an inclusion criterion; less than 30 participants were diagnosed with tuberculosis; early research assays without clearly defined cutoffs were tested; and humans were not studied. We extracted study-level data, and authors of eligible studies were invited to contribute deidentified individual participant data. The main outcomes were the tuberculosis diagnostic yields of urine lipoarabinomannan tests, sputum NAATs, and SSM. Diagnostic yields were predicted using Bayesian random-effects and mixed-effects meta-analyses. This study is registered with PROSPERO, CRD42021230337. Findings: We identified 844 records, from which 20 datasets and 10 202 participants (4561 [45%] male participants and 5641 [55%] female participants) were included in the meta-analysis. All studies assessed sputum Xpert (MTB/RIF or Ultra, Cepheid, Sunnyvale, CA, USA) and urine Alere Determine TB LAM (AlereLAM, Abbott, Chicago, IL, USA) in people living with HIV aged 15 years or older. Nearly all (9957 [98%] of 10 202) participants provided urine, and 82% (8360 of 10 202) provided sputum within 2 days. In studies that enrolled unselected inpatients irrespective of tuberculosis symptoms, only 54% (1084 of 1993) of participants provided sputum, whereas 99% (1966 of 1993) provided urine. Diagnostic yield was 41% (95% credible interval [CrI] 15–66) for AlereLAM, 61% (95% Crl 25–88) for Xpert, and 32% (95% Crl 10–55) for SSM. Heterogeneity existed across studies in the diagnostic yield, influenced by CD4 cell count, tuberculosis symptoms, and clinical setting. In predefined subgroup analyses, all tests had higher yields in symptomatic participants, and AlereLAM yield was higher in those with low CD4 counts and inpatients. AlereLAM and Xpert yields were similar among inpatients in studies enrolling unselected participants who were not assessed for tuberculosis symptoms (51% vs 47%). AlereLAM and Xpert together had a yield of 71% in unselected inpatients, supporting the implementation of combined testing strategies. Interpretation: AlereLAM, with its rapid turnaround time and simplicity, should be prioritised to inform tuberculosis therapy among inpatients who are HIV-positive, regardless of symptoms or CD4 cell count. The yield of sputum-based tuberculosis tests is undermined by people living with HIV who cannot produce sputum, whereas nearly all participants are able to provide urine. The strengths of this meta-analysis are its large size, the carefully harmonised denominator, and the use of Bayesian random-effects and mixed-effects models to predict yields; however, data were geographically restricted, clinically diagnosed tuberculosis was not considered in the denominator, and little information exists on strategies for obtaining sputum samples. Funding: FIND, the Global Alliance for Diagnostics

    The flame retardant DE-71 (a mixture of polybrominated diphenyl ethers) inhibits human differentiated thyroid cell function in vitro

    Get PDF
    Normal thyroid function is essential for general growth and metabolism, but can be affected by endocrine disrupting chemicals (EDCs). Polybrominated diphenyl ethers (PBDEs) have been used worldwide to reduce flammability in different materials and are suspected to be EDCs. The production of the commercial Penta- and OctaBDE mixtures is banned, but DecaBDEs and existing products may leak PBDEs into the environment. Our aim was to investigate the effect of the PentaBDE mixture DE-71 on human thyroid cells in vitro. Primary human thyroid cells were obtained as paraadenomatous tissue and cultured in monolayers. The influence of DE-71 on cyclic adenosine monophosphate (cAMP) and thyroglobulin (Tg) production was examined in the culture medium by competitive radioimmunoassay and enzyme-linked immunosorbent assay, respectively. Real-time quantitative PCR analysis of thyroid-specific genes was performed on the exposed cell cultures. PBDE concentrations were determined in cellular and supernatant fractions of the cultures. DE-71 inhibited Tg-release from TSH-stimulated thyrocytes. At 50 mg/L DE-71, mean Tg production was reduced by 71.9% (range: 8.5-98.7%), and cAMP by 95.1% (range: 91.5-98.8%) compared to controls). Expression of mRNA encoding Tg, TPO and TSHr were significantly inhibited (
    corecore