23 research outputs found

    Performance of re-ranking techniques used for recommendation method to the user CF- Model

    Get PDF
    The recent research work for addressed to the aims at a spectrum of item ranking techniques that would generate recommendations with far more aggregate variability across all users while retaining comparable levels of recommendation accuracy. Individual users and companies are increasingly relying on recommender systems to provide information on individual suggestions. The recommended technologies are becoming increasingly efficient because they are focusing on scalable sorting-based heuristics that make decisions based solely on "local" data (i.e., only on the candidate items of each user) rather than having to keep track of "national" data, such as items have been all user recommended at the time. The real-world rating datasets and various assessments to be the prediction techniques and comprehensive empirical research consistently demonstrate the proposed techniques' diversity gains. Although the suggested approaches have primarily concentrated on improving recommendation accuracy, other critical aspects of recommendation quality, such as recommendation delivery, have often been ignored

    NEW CLASSIFICATION AND COLOUR CODE DEVELOPMENT FOR AN EFFICIENT MEDICAL WASTE SEGREGATION

    Get PDF
    Medical waste poses serious threat to the environmental health without comprehensive guidelines and efficient management as it contains highly toxic chemicals, pathogenic viruses and bacteria. Therefore, proper handling of medical waste with specialised treatment from its source to final disposal has been a primary concern among medical institute, public and private agencies. The existing medical waste classification in many countries does not contain clear and appropriate segregation, which has created confusion among the medical staff in handling medical waste.  It is pertinent to mention that, World Health Organisation (WHO) guidance recommends different countries to conduct assessments prior to any decision-making process and improve their own guidelines incorporated with recent technologies. Therefore, the objectives of this research are: 1) to develop a new classification of medical wastes by identifying the gaps in the current classes and 2) to suggest colour code for the medical waste segregation that is adopted from the WHO's colour code with few amendments as per the recent technological development. Due to the challenge in managing medical waste, there is an urgent need in developing and adopting comprehensive medical waste segregation classification to separate the medical waste at the source itself. The methodology of classification is aimed at applying a source separation practiced by the medical personnel on the spot and given them awareness on the segregation process. The proposed new classification of medical waste is based on Malaysia's Scheduled Waste Regulations together with European Waste Code. By extracting the best classification from these two regulations and by overcoming the lacuna in them, a new classification is developed for current use. The developed medical waste classification and its colour codes must provide a better segregation and achieve cost saving at waste disposal. The current methods of classification could be extended to research on application of such classification to other parts of the world

    Investigation on Effect of Material Hardness in High Speed CNC End Milling Process

    Get PDF
    This research paper analyzes the effects of material properties on surface roughness, material removal rate, and tool wear on high speed CNC end milling process with various ferrous and nonferrous materials. The challenge of material specific decision on the process parameters of spindle speed, feed rate, depth of cut, coolant flow rate, cutting tool material, and type of coating for the cutting tool for required quality and quantity of production is addressed. Generally, decision made by the operator on floor is based on suggested values of the tool manufacturer or by trial and error method. This paper describes effect of various parameters on the surface roughness characteristics of the precision machining part. The prediction method suggested is based on various experimental analysis of parameters in different compositions of input conditions which would benefit the industry on standardization of high speed CNC end milling processes. The results show a basis for selection of parameters to get better results of surface roughness values as predicted by the case study results

    Simultano UV-spektrofotometrijsko određivanje ramiprila, acetilsalicilne kiseline i atorvastatin kalcija u kapsulama primjenom kemometrijskih metoda

    Get PDF
    In the present work, three different spectrophotometric methods for simultaneous estimation of ramipril, aspirin and atorvastatin calcium in raw materials and in formulations are described. Overlapped data was quantitatively resolved by using chemometric methods, viz. inverse least squares (ILS), principal component regression (PCR) and partial least squares (PLS). Calibrations were constructed using the absorption data matrix corresponding to the concentration data matrix. The linearity range was found to be 1-5, 10-50 and 2-10 Āµg mLā€“1 for ramipril, aspirin and atorvastatin calcium, respectively. The absorbance matrix was obtained by measuring the zero-order absorbance in the wavelength range between 210 and 320 nm. A training set design of the concentration data corresponding to the ramipril, aspirin and atorvastatin calcium mixtures was organized statistically to maximize the information content from the spectra and to minimize the error of multivariate calibrations. By applying the respective algorithms for PLS 1, PCR and ILS to the measured spectra of the calibration set, a suitable model was obtained. This model was selected on the basis of RMSECV and RMSEP values. The same was applied to the prediction set and capsule formulation. Mean recoveries of the commercial formulation set together with other figures of merit (calibration sensitivity, selectivity, limit of detection, limit of quantification and analytical sensitivity) were estimated. Validity of the proposed approaches was successfully assessed for analyses of drugs in the various prepared physical mixtures and formulations.U radu su opisane tri različite spektrofotometrijske metode za određivanje ramiprila, acetilsalicilne kiseline i atorvastatin kalcija u sirovinama i formulacijama. Preklapanje podataka kvantitativno je rijeÅ”eno pomoću kemometrijskih metoda, tj. metodama inverznih najmanjih kvadrata (ILS), regresije glavnog sastojka (PCR) i djelomičnih najmanjih kvadrata (PLS). Kalibracije su postavljene pomoću matrice podataka za apsorpciju koja odgovara matrici pripadajućih koncentracija. Područje linearnosti za ramipril iznosilo je 1ā€“5, za acetilsalicilnu kiselinu 10ā€“50, a za atorvastatin kalcij 2ā€“10 Āµg mLā€“1. Matrica s apsorbancijama dobivena je mjerenjem apsorbancije nultog reda na valnim duljinama između 210 i 320 nm. Set podataka za koncentracije ramiprila, acetilsalicilne kiseline i atorvastatin kalcija u smjesi statistički je tako organiziran da osigura maksimalnu količinu informacije u spektrima i minimalizira greÅ”ku multivarijantnih kalibracija. Primjenom odgovarajućih algoritama za PLS, PCR i ILS na snimljene spektre kalibracijskog seta dobiven je dobar model, koji je odabran na temelju RMSECV i RMSEP vrijednosti. Isti model je primijenjen i na set s predviđenim vrijednostima i na kapsule sa smjesom ove tri ljekovite tvari. Određena je srednja vrijednost povrata za komercijalnu formulaciju te ostale analitičke izvedbene značajke (kalibracijska osjetljivost, selektivnost, granica dokazivanja, granica određivanja i analitička osjetljivost). Potvrđena je primjenjljivost predloženih metoda u analizama lijekova u fizičkim smjesama i u gotovim ljekovitim oblicima

    Fabrication of Planar Perovskite Solar Cells Using Ternary Metal Oxide Nanocomposite as Hole-Transporting Material

    No full text
    This work uses a hole-transporting copper cobaltite/copper oxide nanocomposite to fabricate carbon-based MAPbI3 PSCs. The copper cobaltite/copper oxide HTM-based PSC results show the highest power conversion efficiency (PCE = 7.32%) compared with an HTM-free device. The highest photocurrent density (Jsc = 15.17 mA/cm2), open-circuit voltage (Voc = 0.82 V), and fill factor (FF = 0.59) are achieved for the PSC fabricated with hydrothermally synthesized copper cobaltite/copper oxide nanocomposites. Electrochemical impedance spectroscopy is used to analyze the charge transfer resistance (Rs) and the capacitive behavior of copper cobaltite/copper oxide nanocomposite. The maximum electron lifetime of 35.16 Ī¼s is witnessed for the PSCs fabricated with 3 mg mLāˆ’1 of copper cobaltite/copper oxide (H1). The efficiency of the copper cobaltite/copper oxide-based PSC remains unchanged, showing no further perovskite layer degradation
    corecore