    Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine

    Get PDF
    BACKGROUND: Recent cadaver studies show stability against axial rotation with a cylindrical cage is marginally superior to a rectangular cage. The purpose of this biomechanical study in cadaver spine was to evaluate the stability of a new rectangular titanium cage design, which has teeth similar to the threads of cylindrical cages to engage the endplates. METHODS: Ten motion segments (five L2-3, five L4-5) were tested. From each cadaver spine, one motion segment was fixed with a pair of cylindrical cages (BAK, Sulzer Medica) and the other with paired rectangular cages (Rotafix, Corin Spinal). Each specimen was tested in an unconstrained state, after cage introduction and after additional posterior translaminar screw fixation. The range of motion (ROM) in flexion-extension, lateral bending, and rotation was tested in a materials testing machine, with +/- 5 Nm cyclical load over 10 sec per cycle; data from the third cycle was captured for analysis. RESULTS: ROM in all directions was significantly reduced (p < 0.05) with both types of cages. There was no significant difference in reduction of ROM in flexion-extension (p = 0.6) and rotation (p = 0.92) between the two cage groups, but stability in lateral bending was marginally superior with the rectangular cages (p = 0.11). Additional posterior fixation further reduced the ROM significantly (p < 0.05) in most directions in both cage groups, but did not show any difference between the cage groups. CONCLUSIONS: There was no significant difference in immediate stability in any direction between the threaded cylindrical cage and the new design of the rectangular cage with endplate teeth

    Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates

    Get PDF
    BACKGROUND: In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. METHOD: In order to address this problem, we propose to use stiffness-graded plates. Accordingly, we have computed (by finite-element analysis) the stress distribution in the fractured bone fixed by composite plates, whose stiffness is graded both longitudinally and transversely. RESULTS: It can be seen that the stiffness-graded composite-plates cause less stress-shielding (as an example: at 50% of the healing stage, stress at the fracture interface is compressive in nature i.e. 0.002 GPa for stainless steel plate whereas stiffness graded plates provides tensile stress of 0.002 GPa. This means that stiffness graded plate is allowing the 50% healed bone to participate in loadings). Stiffness-graded plates are more flexible, and hence permit more bending of the fractured bone. This results in higher compressive stresses induced at the fractured faces accelerate bone-healing. On the other hand, away from the fracture interface the reduced stiffness and elastic modulus of the plate causes the neutral axis of the composite structure to be lowered into the bone resulting in the higher tensile stress in the bone-layer underneath the plate, wherein is conducive to the bone preserving its tensile strength. CONCLUSION: Stiffness graded plates (with in-built variable stiffness) are deemed to offer less stress-shielding to the bone, providing higher compressive stress at the fractured interface (to induce accelerated healing) as well as higher tensile stress in the intact portion of the bone (to prevent bone remodeling and osteoporosis)

    The cost of severe haemophilia in Europe: the CHESS study

    Get PDF
    Background Severe haemophilia is associated with major psychological and economic burden for patients, caregivers, and the wider health care system. This burden has been quantified and documented for a number of European countries in recent years. However, few studies have taken a standardised methodology across multiple countries simultaneously, and sought to amalgamate all three levels of burden for severe disease. The overall aim of the ‘Cost of Haemophilia in Europe: a Socioeconomic Survey’ (CHESS) study was to capture the annualised economic and psychosocial burden of severe haemophilia in five European countries. A cross-section of haemophilia specialists (surveyed between January and April 2015) provided demographic and clinical information and 12-month ambulatory and secondary care activity for patients via an online survey. In turn, patients provided corresponding direct and indirect non-medical cost information, including work loss and out-of-pocket expenses, as well as information on quality of life and adherence. The direct and indirect costs for the patient sample were calculated and extrapolated to population level. Results Clinical reports for a total of 1,285 patients were received. Five hundred and fifty-two patients (43% of the sample) provided information on indirect costs and health-related quality of life via the PSC. The total annual cost of severe haemophilia across the five countries for 2014 was estimated at EUR 1.4 billion, or just under EUR 200,000 per patient. The highest per-patient costs were in Germany (mean EUR 319,024) and the lowest were in the United Kingdom (mean EUR 129,365), with a study average of EUR 199,541. As expected, consumption of clotting factor replacement therapy represented the vast majority of costs (up to 99%). Indirect costs are driven by patient and caregiver work loss. Conclusions The results of the CHESS study reflect previous research findings suggesting that costs of factor replacement therapy account for the vast majority of the cost burden in severe haemophilia. However, the importance of the indirect impact of haemophilia on the patient and family should not be overlooked. The CHESS study highlights the benefits of observational study methodologies in capturing a ‘snapshot’ of information for patients with rare diseases

    Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Initial promise of a stand-alone interbody fusion cage to treat chronic back pain and restore disc height has not been realized. In some instances, a posterior spinal fixation has been used to enhance stability and increase fusion rate. In this manuscript, a new stand-alone cage is compared with conventional fixation methods based on the finite element analysis, with a focus on investigating cage-bone interface mechanics and stress distribution on the adjacent tissues.</p> <p>Methods</p> <p>Three trapezoid 8° interbody fusion cage models (dual paralleled cages, a single large cage, or a two-part cage consisting of a trapezoid box and threaded cylinder) were created with or without pedicle screws fixation to investigate the relative importance of the screws on the spinal segmental response. The contact stress on the facet joint, slip displacement of the cage on the endplate, and rotational angle of the upper vertebra were measured under different loading conditions.</p> <p>Results</p> <p>Simulation results demonstrated less facet stress and slip displacement with the maximal contact on the cage-bone interface. A stand-alone two-part cage had good slip behavior under compression, flexion, extension, lateral bending and torsion, as compared with the other two interbody cages, even with the additional posterior fixation. However, the two-part cage had the lowest rotational angles under flexion and torsion, but had no differences under extension and lateral bending.</p> <p>Conclusion</p> <p>The biomechanical benefit of a stand-alone two-part fusion cage can be justified. This device provided the stability required for interbody fusion, which supports clinical trials of the cage as an alternative to circumferential fixations.</p

    Dickkopf1 Regulates Fate Decision and Drives Breast Cancer Stem Cells to Differentiation: An Experimentally Supported Mathematical Model

    Get PDF
    BACKGROUND: Modulation of cellular signaling pathways can change the replication/differentiation balance in cancer stem cells (CSCs), thus affecting tumor growth and recurrence. Analysis of a simple, experimentally verified, mathematical model suggests that this balance is maintained by quorum sensing (QS). METHODOLOGY/PRINCIPAL FINDINGS: To explore the mechanism by which putative QS cellular signals in mammary stem cells (SCs) may regulate SC fate decisions, we developed a multi-scale mathematical model, integrating extra-cellular and intra-cellular signal transduction within the mammary tissue dynamics. Preliminary model analysis of the single cell dynamics indicated that Dickkopf1 (Dkk1), a protein known to negatively regulate the Wnt pathway, can serve as anti-proliferation and pro-maturation signal to the cell. Simulations of the multi-scale tissue model suggested that Dkk1 may be a QS factor, regulating SC density on the level of the whole tissue: relatively low levels of exogenously applied Dkk1 have little effect on SC numbers, whereas high levels drive SCs into differentiation. To verify these model predictions, we treated the MCF-7 cell line and primary breast cancer (BC) cells from 3 patient samples with different concentrations and dosing regimens of Dkk1, and evaluated subsequent formation of mammospheres (MS) and the mammary SC marker CD44(+)CD24(lo). As predicted by the model, low concentrations of Dkk1 had no effect on primary BC cells, or even increased MS formation among MCF-7 cells, whereas high Dkk1 concentrations decreased MS formation among both primary BC cells and MCF-7 cells. CONCLUSIONS/SIGNIFICANCE: Our study suggests that Dkk1 treatment may be more robust than other methods for eliminating CSCs, as it challenges a general cellular homeostasis mechanism, namely, fate decision by QS. The study also suggests that low dose Dkk1 administration may be counterproductive; we showed experimentally that in some cases it can stimulate CSC proliferation, although this needs validating in vivo

    Development and evaluation of a tool for the assessment of footwear characteristics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Footwear characteristics have been linked to falls in older adults and children, and the development of many musculoskeletal conditions. Due to the relationship between footwear and pathology, health professionals have a responsibility to consider footwear characteristics in the etiology and treatment of various patient presentations. In order for health professionals and researchers to accurately and efficiently critique an individual's footwear, a valid and reliable footwear assessment tool is required. The aim of this study was to develop a simple, efficient, and reliable footwear assessment tool potentially suitable for use in a range of patient populations.</p> <p>Methods</p> <p>Consideration of previously published tools, other footwear related literature, and clinical considerations of three therapists were used to assist in the development of the tool. The tool was developed to cover fit, general features, general structure, motion control properties, cushioning, and wear patterns. A total of 15 participants (who provided two pairs of shoes each) were recruited, and assessment using the scale was completed on two separate occasions (separated by 1 – 3 weeks) by a physiotherapist and a podiatrist on each participant's dominant foot. Intra-rater and inter-rater reliability were evaluated using intra-class correlation coefficients (ICCs) (model 2, 1) and the 95% limits of agreement (95% LOAs) for continuous items, and percentage agreement and kappa (κ) statistics for categorical items.</p> <p>Results</p> <p>All categorical items demonstrated high percentage agreement statistic for intra-rater (83 – 100%) and inter-rater (83 – 100%) comparisons. With the exception of last shape and objective measures used to categorise the adequacy of length, excellent intra-rater (ICC = 0.91 – 1.00) and inter-rater reliability (ICC = 0.90 – 1.00) was indicated for continuous items in the tool, including the motion control properties scale (0.91 – 0.95).</p> <p>Conclusion</p> <p>A comprehensive footwear assessment tool with good face validity has been developed to assist future research and clinical footwear assessment. Generally good reliability amongst all items indicates that the tool can be used with confidence in research and clinical settings. Further research is now required to determine the clinical validity of each item in various patient populations.</p
    • …