965 research outputs found

    股骨旋轉的放射學評估:屍體標本研究

    Get PDF
    Purpose: To define how the lesser trochanter can be used in an objective manner to assess the femoral rotation in plain radiograph. Methods: Eighteen pairs of cadaveric femurs from Chinese individuals were used in this study. For each femur, radiographs were taken in the following positions with reference to the anatomical transepicondylar axis: neutral position; 5°, 10°, 15°, and 20° internal rotation; and 5°, 10°, 15°, and 20° external rotation. Lesser-trochanter index, which was defined as the width of lesser trochanter divided by the remaining width of the proximal femur, measured at the level of its most prominent point, which was perpendicular to the anatomical axis of the proximal femur, was obtained on a Picture Archiving Communication System workstation in every radiograph. Statistical analyses were performed by using a statistical software R (R language, version 2.12.0). Results: The lesser-trochanter index showed positive correlation with increasing external rotation of femur: correlation coefficient = 0.75 (p<0.00001). Analysis-of-variance test showed that the lesser-trochanter indexes of Group 1 (20° and 15° internal rotation), Group 2 (10° internal rotation to 10° external rotation), and Group 3 (15° and 20° external rotation) had statistically significant differences (p<0.00001). Receiver operating characteristic curves were used to determine the cutoff value of lesser-trochanter index to distinguish the three groups. By using the lower cutoff value as 0.17, we can distinguish Group 2 from Group 1 with a sensitivity of 0.85 and a specificity of 0.65. By using the upper cutoff value as 0.28, we can distinguish Group 2 from Group 3 with a sensitivity of 0.80 and a specificity of 0.73. Conclusion: The lesser-trochanter index can be used as a method to assess the rotational alignment of femur in plain radiograph. It is simple, objective, not affected by the factor of magnification, and can be applied to both long and short films. © 2012.link_to_subscribed_fulltex

    A Mechanical Mass Sensor with Yoctogram Resolution

    Full text link
    Nanoelectromechanical systems (NEMS) have generated considerable interest as inertial mass sensors. NEMS resonators have been used to weigh cells, biomolecules, and gas molecules, creating many new possibilities for biological and chemical analysis [1-4]. Recently, NEMS-based mass sensors have been employed as a new tool in surface science in order to study e.g. the phase transitions or the diffusion of adsorbed atoms on nanoscale objects [5-7]. A key point in all these experiments is the ability to resolve small masses. Here we report on mass sensing experiments with a resolution of 1.7 yg (1 yg = 10^-24 g), which corresponds to the mass of one proton, or one hydrogen atom. The resonator is made of a ~150 nm long carbon nanotube resonator vibrating at nearly 2 GHz. The unprecedented level of sensitivity allows us to detect adsorption events of naphthalene molecules (C10H8) and to measure the binding energy of a Xe atom on the nanotube surface (131 meV). These ultrasensitive nanotube resonators offer new opportunities for mass spectrometry, magnetometry, and adsorption experiments.Comment: submitted version of the manuscrip

    The Hong Kong mental morbidity survey: background and study design

    Get PDF
    Mental disorders are highly prevalent conditions with immense disease burden. To inform health and social services policy formulation, local psychiatric epidemiological data are required. The Hong Kong Mental Morbidity Survey is a 3-year population-based study in which 5700 community-dwelling Chinese adults aged between 16 and 75 years were interviewed with the aim of evaluating the prevalence, co-morbidity, functional impairment, physical morbidity, and social determinants of significant mental disorders in the population. This paper describes the background and design of the survey, and is the first territory-wide psychiatric epidemiological study in Hong Kong. 精神障礙非常普遍,且對社會造成巨大的疾病負擔。收集本地精神病流行病學資料,對計劃相關的衛生及社會服務政策至為重要。香港精神健康調查是一個為期3年,以人口為基礎的大型研究,透過對5700名介乎16歲至75歲之華裔市民進行精神健康評估,檢視重要的精神障礙的現患率、共病、功能障礙、身體疾病以及社會決定因素。本文闡述這項首個全港大型精神病流行病研究的背景和設計。published_or_final_versio

    Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Several cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported.</p> <p>Case presentation</p> <p>In November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty. In March 2008, while rising from a chair, she felt a sudden pain and instability in her left knee. She reported a fracture of the polyethylene post of the tibial insert. No malposition or malalignment of either the femoral or tibial components were identified. The polyethylene tibial insert was studied under light microscopy and scanning electron microscopy. The fracture was also noted to have occurred without any notable polyethylene wear.</p> <p>Conclusion</p> <p>Scanning electron microscopy revealed two different damage patterns that could be explained with a two-stage rupture of our patient's polyethylene post. This could have been caused by a non-optimal ligamentous balancing during first implant surgery. Her knee probably developed a varus instability that weakened the post, and then a posterior anterior stress finally broke the polyethylene.</p

    Combinatorial Computational Approaches to Identify Tetracycline Derivatives as Flavivirus Inhibitors

    Get PDF
    Limited structural information of drug targets, cellular toxicity possessed by lead compounds, and large amounts of potential leads are the major issues facing the design-oriented approach of discovering new leads. In an attempt to tackle these issues, we have developed a process of virtual screening based on the observation that conformational rearrangements of the dengue virus envelope protein are essential for the mediation of viral entry into host cells via membrane fusion. Screening was based solely on the structural information of the Dengue virus envelope protein and was focused on a target site that is presumably important for the conformational rearrangements necessary for viral entry. To circumvent the issue of lead compound toxicity, we performed screening based on molecular docking using structural databases of medical compounds. To enhance the identification of hits, we further categorized and selected candidates according to their novel structural characteristics. Finally, the selected candidates were subjected to a biological validation assay to assess inhibition of Dengue virus propagation in mammalian host cells using a plaque formation assay. Among the 10 compounds examined, rolitetracycline and doxycycline significantly inhibited plaque formation, demonstrating their inhibitory effect on dengue virus propagation. Both compounds were tetracycline derivatives with IC(50)s estimated to be 67.1 µM and 55.6 µM, respectively. Their docked conformations displayed common hydrophobic interactions with critical residues that affected membrane fusion during viral entry. These interactions will therefore position the tetracyclic ring moieties of both inhibitors to bind firmly to the target and, subsequently, disrupt conformational rearrangement and block viral entry. This process can be applied to other drug targets in which conformational rearrangement is critical to function

    Effect of pathology type and severity on the distribution of MRI signal intensities within the degenerated nucleus pulposus: application to idiopathic scoliosis and spondylolisthesis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Disc degeneration is characterized by a loss of cellularity, degradation of the extracellular matrix, and, as a result, morphological changes and biomechanical alterations. We hypothesized that the distribution of the MR signal intensity within the nucleus zone of the intervertebral disc was modified according to the pathology and the severity of the pathology. The objective of this study was to propose new parameters characterizing the distribution of the signal intensity within the nucleus zone of lumbar intervertebral discs, and to quantify these changes in patients suffering from spondylolisthesis or idiopathic scoliosis.</p> <p>Methods</p> <p>A retrospective study had been performed on T2-weighted MR images of twenty nine patients suffering from spondylolisthesis and/or scoliosis. The high intensity zone of the nucleus pulposus was semi-automatically detected. The distance "DX" between the center weighted by the signal intensity and the geometrical center was quantified. The sum of the signal intensity on the axis perpendicular to the longitudinal axis of the disc was plotted for each position of the longitudinal axis allowing defining the maximum sum "SM" and its position "PSM".</p> <p>Results</p> <p>"SM" was clearly higher and "PSM" was more shifted for scoliosis than for spondylolisthesis. A two-way analysis of variance showed that the differences observed on "DX" were not attributed to the pathology nor its severity, the differences observed on "SM" were attributed to the pathology but not to its severity, and the differences observed on "PSM" were attributed to both the pathology and its severity.</p> <p>Conclusions</p> <p>The technique proposed in this study showed significant differences in the distribution of the MR signal intensity within the nucleus zone of intervertebral discs due to the pathology and its severity. The dependence of the "PSM" parameter to the severity of the pathology suggests this parameter as a predictive factor of the pathology progression. This new technique should be useful for the early diagnosis of intervertebral disc pathologies as it highlights abnormal patterns in the MRI signal for low severity of the pathology.</p
    corecore