151 research outputs found

    Behavior of Braced Cut in Connection with Construction of Large Underground Station

    Get PDF
    Ueno underground station of the Shinkansen is a large scale underground station constructed in relatively stable diluvial layers. The construction was conducted with elaborated comparative designing, and with carefully controlled measurements referring estimated values, because data about design and construction of this kind of large underground station are rare. Primary estimations are qualitatively in good agreement with actual measured values, while quantitatively they do not agree well with the actual values. But the accuracy of the method of estimation will be increased in the future when more data about earth pressure of stable grounds are accumulated. Behavior of a diaphragm underground wall as a temporary structure, changes in groundwater level and displacement of the bottom of excavation are described in this paper

    Population III X-ray Binaries and their Impact on the Early Universe

    Full text link
    The first population of X-ray binaries (XRBs) is expected to affect the thermal and ionization states of the gas in the early Universe. Although these X-ray sources are predicted to have important implications for high-redshift observable signals, such as the hydrogen 21-cm signal from cosmic dawn and the cosmic X-ray background, their properties are poorly explored, leaving theoretical models largely uninformed. In this paper we model a population of X-ray binaries arising from zero metallicity stars. We explore how their properties depend on the adopted initial mass function (IMF) of primordial stars, finding a strong effect on their number and X-ray production efficiency. We also present scaling relations between XRBs and their X-ray emission with the local star formation rate, which can be used in sub-grid models in numerical simulations to improve the X-ray feedback prescriptions. Specifically, we find that the uniformity and strength of the X-ray feedback in the intergalactic medium is strongly dependant on the IMF. Bottom-heavy IMFs result in a smoother distribution of XRBs, but have a luminosity orders of magnitude lower than more top-heavy IMFs. Top-heavy IMFs lead to more spatially uneven, albeit strong, X-ray emission. An intermediate IMF has a strong X-ray feedback while sustaining an even emission across the intergalactic medium. These differences in X-ray feedback could be probed in the future with measurements of the cosmic dawn 21-cm line of neutral hydrogen, which offers us a new way of constraining population III IMF.Comment: Accepted for publication in MNRAS, 17 pages, 9 figure

    Prognostic Tools in Patients with Advanced Cancer: A Systematic Review

    Get PDF
    Purpose: In 2005, the European Association for Palliative Care (EAPC) made recommendations for prognostic markers in advanced cancer. Since then, prognostic tools have been developed, evolved and validated. The aim of this systematic review was to examine the progress in the development and validation of prognostic tools. Methods: Medline, Embase Classic + and Embase were searched. Eligible studies met the following criteria: patients with incurable cancer; >18 years; original studies; population n>100; published after 2003. Descriptive and quantitative statistical analyses were performed. Results: Forty-nine studies were eligible, assessing seven prognostic tools across different care settings, primary cancer types and statistically assessed survival prediction. The (PPS) Palliative Performance Scale was the most studied (n=21,082), composed of 6 parameters (6 subjective), was externally validated and predicted survival. The Palliative Prognostic Score (PaP) composed of 6 parameters (4 subjective, 2 objective), the Palliative Prognostic Index (PPI) composed of 9 parameters (9 subjective), and the Glasgow Prognostic Score (GPS) composed of 2 parameters (2 objective), and were all externally validated in more than 2000 patients with advanced cancer and predicted survival. Conclusion: Various prognostic tools have been validated, but vary in their complexity, subjectivity and therefore clinical utility. The GPS would seem the most favourable as it uses only two parameters (both objective) and has prognostic value complementary to the gold standard measure, which is performance status. Further studies comparing all proven prognostic markers in a single cohort of patients with advanced cancer, are needed to determine the optimal prognostic tool

    Modulation of Mouse Coagulation Gene Transcription following Acute In Vivo Delivery of Synthetic Small Interfering RNAs Targeting HNF4α and C/EBPα

    Get PDF
    Hepatocyte nuclear factor 4α (HNF4α) and CCAAT/enhancer-binding protein α (C/EBPα) are important for the transcriptional control of coagulation factors. To determine in vivo the direct role of HNF4α and C/EBPα in control of genes encoding coagulation factors, a synthetic small interfering (si)RNA approach was used that enabled strong reduction of mouse hepatic HNF4α and C/EBPα under conditions that minimized target-related secondary effects. For both HNF4α and C/EBPα, intravenous injection of specific synthetic siRNAs (siHNF4α and siC/EBPα) resulted in more than 75% reduction in their liver transcript and protein levels 2 days post-injection. For siHNF4α, this coincided with marked and significantly reduced transcript levels of the coagulation genes Hrg, Proz, Serpina5, F11, F12, F13b, Serpinf2, F5, and F9 (in order of magnitude of effect) as compared to levels in control siRNA injected animals. Significant decreases in HNF4α target gene mRNA levels were also observed at 5 days post-siRNA injection, despite a limited level of HNF4α knockdown at this time point. Compared to HNF4α, C/EBPα knockdown had a modest impact on genes encoding coagulation factors. A strong reduction in C/EBPα transcript and protein levels resulted in significantly affected transcript levels of the control genes Pck1 and Fasn and a modest downregulation for coagulation genes Fba, Fbg and F5. F5 and F11 were the sole coagulation genes that were significantly affected upon prolonged (5 day) C/EBPα knockdown. We conclude that in the mouse, HNF4α has a direct and essential regulatory role for multiple hepatic coagulation genes, while a role for C/EBPα is more restricted. In addition, this study demonstrates that synthetic siRNA provides a simple and fast means for determining liver transcription factor involvement in vivo

    Dopamine and Glutamate in Antipsychotic-Responsive Compared With Antipsychotic-Nonresponsive Psychosis: A Multicenter Positron Emission Tomography and Magnetic Resonance Spectroscopy Study (STRATA)

    Get PDF
    The variability in the response to antipsychotic medication in schizophrenia may reflect between-patient differences in neurobiology. Recent cross-sectional neuroimaging studies suggest that a poorer therapeutic response is associated with relatively normal striatal dopamine synthesis capacity but elevated anterior cingulate cortex (ACC) glutamate levels. We sought to test whether these measures can differentiate patients with psychosis who are antipsychotic responsive from those who are antipsychotic nonresponsive in a multicenter cross-sectional study. 1H-magnetic resonance spectroscopy (1H-MRS) was used to measure glutamate levels (Glucorr) in the ACC and in the right striatum in 92 patients across 4 sites (48 responders [R] and 44 nonresponders [NR]). In 54 patients at 2 sites (25 R and 29 NR), we additionally acquired 3,4-dihydroxy-6-[18F]fluoro-L-phenylalanine (18F-DOPA) positron emission tomography (PET) to index striatal dopamine function (Kicer, min−1). The mean ACC Glucorr was higher in the NR than the R group after adjustment for age and sex (F1,80 = 4.27; P = .04). This was associated with an area under the curve for the group discrimination of 0.59. There were no group differences in striatal dopamine function or striatal Glucorr. The results provide partial further support for a role of ACC glutamate, but not striatal dopamine synthesis, in determining the nature of the response to antipsychotic medication. The low discriminative accuracy might be improved in groups with greater clinical separation or increased in future studies that focus on the antipsychotic response at an earlier stage of the disorder and integrate other candidate predictive biomarkers. Greater harmonization of multicenter PET and 1H-MRS may also improve sensitivity
    • …
    corecore