1,333 research outputs found

    Calculations of electric currents in Europa

    Get PDF
    Electrical currents should flow in the Galilean satellite, Europa, because it is located in Jupiter's corotating magnetosphere. The possible magnitudes of these currents are calculated by assuming that Europa is a differentiated body consisting of an outer H2O layer and a silicate core. Two types of models are considered here: one in which the water is completely frozen and a second in which there is an intermediate liquid layer. For the transverse electric mode (eddy currents), the calculated current density in a liquid layer is approximately 10 to the -5/Am. For the transverse magnetic mode (unipolar generator), the calculated current density in the liquid is severely constrained by the ice layer to a range of only 10 to the -10 to -11th power/ Am, for a total H2O thickness of 100 km, provided that neither layer is less than 4 km thick. The current density is less for a completely frozen H2O layer. If transient cracks were to appear in the ice layer, thereby exposing liquid, the calculated current density could rise to a range of 10 to the -6 to 10 to the -5/Am, depending on layer thicknesses, which would require an exposed area of 10 to the -9 to 10 to the -8 of the Europa surface. The corresponding total current of 2.3x10 to the 5th power A could in 1 yr. electrolyze 7x10 to the 5th power kg of water (and more if the cells were in series), and thereby store up to 10 the 8th power J of energy, but it is not clear how electrolysis can take place in the absence of suitable electrodes. Electrical heating would be significant only if the ice-layer thickness were on the order of 1 m, such as might occur if an exposed liquid surface were to freeze over; the heating under this condition could hinder the thickening of the ice layer

    The Effects of Stacking on the Configurations and Elasticity of Single Stranded Nucleic Acids

    Full text link
    Stacking interactions in single stranded nucleic acids give rise to configurations of an annealed rod-coil multiblock copolymer. Theoretical analysis identifies the resulting signatures for long homopolynucleotides: A non monotonous dependence of size on temperature, corresponding effects on cyclization and a plateau in the extension force law. Explicit numerical results for poly(dA) and poly(rU) are presented.Comment: 4 pages and 2 figures. Accepted in Phys. Rev. E Rapid Com

    A modified monomolecular film test for micro-quantities of lipids in foods

    Get PDF
    This bulletin is a report on Department of Poultry Husbandry research project 17, Egg Utilization--P. [3].Digitized 2007 AES.Includes bibliographical references (page 30)

    Activation mechanism of rabbit skeletal muscle myosin light chain kinase 5′-p-Fluorosulfonylbenzoyl adenosine as a probe of the MgATP-binding site of the calmodulin-bound and calmodulin-free enzyme

    Get PDF
    Abstract5′-p-Fluorosulfonylbenzoyl adenosine (FSBA), an ATP-like affinity labelling reagent, reacted with rabbit skeletal muscle myosin light chain kinase (skMLCK) and its calmodulin complex in a site-specific manner. Reaction was dependent upon the presence of the adenosine moiety of FSBA, saturated with increasing FSBA, was inhibited by MgATP, and was accompanied by stoichiometric incorporation of [14C]FSBA. The kinetic constants describing the reaction were similar for skMLCK and its calmodulin complex: k3= −0.040 min−1 and −0.038 mint-1, and Ki=0.18 mM and 0.40 mM, respectively. It is concluded that the MgATP-binding site on skMLCK remains accessible at all times and maintains a near constant conformation

    On malfunctioning software

    Get PDF
    Artefacts do not always do what they are supposed to, due to a variety of reasons, including manufacturing problems, poor maintenance, and normal wear-and-tear. Since software is an artefact, it should be subject to malfunctioning in the same sense in which other artefacts can malfunction. Yet, whether software is on a par with other artefacts when it comes to malfunctioning crucially depends on the abstraction used in the analysis. We distinguish between “negative” and “positive” notions of malfunction. A negative malfunction, or dysfunction, occurs when an artefact token either does not (sometimes) or cannot (ever) do what it is supposed to. A positive malfunction, or misfunction, occurs when an artefact token may do what is supposed to but, at least occasionally, it also yields some unintended and undesirable effects. We argue that software, understood as type, may misfunction in some limited sense, but cannot dysfunction. Accordingly, one should distinguish software from other technical artefacts, in view of their design that makes dysfunction impossible for the former, while possible for the latter

    Human interaural time difference thresholds for sine tones: The high-frequency limit

    Full text link
    [EN] The smallest detectable interaural time difference (ITD) for sine tones was measured for four human listeners to determine the dependence on tone frequency. At low frequencies, 250 700 Hz, threshold ITDs were approximately inversely proportional to tone frequency. At mid-frequencies, 700 1000 Hz, threshold ITDs were smallest. At high frequencies, above 1000 Hz, thresholds increased faster than exponentially with increasing frequency becoming unmeasurably high justabove 1400 Hz. A model for ITD detection began with a biophysically based computational model for a medial superior olive (MSO) neuron that produced robust ITD responses up to 1000 Hz, and demonstrated a dramatic reduction in ITD-dependence from 1000 to 1500 Hz. Rate-ITD functions from the MSO model became inputs to binaural display models both place based and rate-differ-ence based. A place-based, centroid model with a rigid internal threshold reproduced almost all fea- tures of the human data. A signal-detection version of this model reproduced the high-frequence divergence but badly underestimated low-frequency thresholds. A rate-difference model incorporat- ing fast contralateral inhibition reproduced the major features of the human threshold data except for the divergence. A combined, hybrid model could reproduce all the threshold data.We are grateful to Dr. Les Bernstein for a useful discussion about the centroid display and to Dr. Steve Colburn for discussions about modeling. Zane Crawford provided valuable statistical help. This research was supported by The Vicerectorado de Profesorado y Ordenacion Academica of the Universitat Politecnica de Valencia (Spain), which brought L. D. to Michigan State, by the NIDCD Grant No. DC-00181 and the AFOSR Grant No. 11NL002. A. B. was supported by NIDCD Grant Nos. DC-00100 (H. S. Colburn) and P30-DC04663 (Core Center).Brughera, A.; Dunai ., L.; Hartmann, WM. (2013). Human interaural time difference thresholds for sine tones: The high-frequency limit. The Journal of the Acoustical Society of America. 133(5):2839-2855. https://doi.org/10.1121/1.4795778S28392855133

    Micro-fabrication of Carbon Structures by Pattern Miniaturization in Resorcinol-Formaldehyde Gel

    Full text link
    A simple and novel method to fabricate and miniaturize surface and sub-surface micro-structures and micro-patterns in glassy carbon is proposed and demonstrated. An aqueous resorcinol-formaldehyde (RF) sol is employed for micro-molding of the master-pattern to be replicated, followed by controlled drying and pyrolysis of the gel to reproduce an isotropically shrunk replica in carbon. The miniaturized version of the master-pattern thus replicated in carbon is about one order of magnitude smaller than original master by repeating three times the above cycle of molding and drying. The micro-fabrication method proposed will greatly enhance the toolbox for a facile fabrication of a variety of Carbon-MEMS and C-microfluidic devices.Comment: 16 pages, 5 figure

    The State of the Region: Hampton Roads 2003

    Get PDF
    This is Old Dominion University\u27s fourth annual State of the Region report. While it represents the work of many people connected in various ways to the university, the report does not constitute an official viewpoint of Old Dominion, or it\u27s president, Dr. Roseann Runte. The report maintains the goal of stimulating thought and discussion that ultimately will make Hampton Roads an even better place to live. We are proud of our region\u27s many successes, but realize that it is possible to improve our performance. In order to do so, we must have accurate information about where we are and a sound understanding of the policy options open to us.https://digitalcommons.odu.edu/economics_books/1015/thumbnail.jp

    Fabrication and characterization of dual function nanoscale pH-scanning ion conductance microscopy (SICM) probes for high resolution pH mapping

    Get PDF
    The easy fabrication and use of nanoscale dual function pH-scanning ion conductance microscopy (SICM) probes is reported. These probes incorporate an iridium oxide coated carbon electrode for pH measurement and an SICM barrel for distance control, enabling simultaneous pH and topography mapping. These pH-SICM probes were fabricated rapidly from laser pulled theta quartz pipets, with the pH electrode prepared by in situ carbon filling of one of the barrels by the pyrolytic decomposition of butane, followed by electrodeposition of a thin layer of hydrous iridium oxide. The other barrel was filled with an electrolyte solution and Ag/AgCl electrode as part of a conductance cell for SICM. The fabricated probes, with pH and SICM sensing elements typically on the 100 nm scale, were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and various electrochemical measurements. They showed a linear super-Nernstian pH response over a range of pH (pH 2–10). The capability of the pH-SICM probe was demonstrated by detecting both pH and topographical changes during the dissolution of a calcite microcrystal in aqueous solution. This system illustrates the quantitative nature of pH-SICM imaging, because the dissolution process changes the crystal height and interfacial pH (compared to bulk), and each is sensitive to the rate. Both measurements reveal similar dissolution rates, which are in agreement with previously reported literature values measured by classical bulk methods
    corecore