24 research outputs found
Blood flow rate estimation in optic disc capillaries and vessels using Doppler optical coherence tomography with 3D fast phase unwrapping
The retinal volumetric flow rate contains useful information not only for ophthalmology but also for the diagnosis of common civilization diseases such as diabetes, Alzheimer's disease, or cerebrovascular diseases. Non-invasive optical methods for quantitative flow assessment, such as Doppler optical coherence tomography (OCT), have certain limitations. One is the phase wrapping that makes simultaneous calculations of the flow in all human retinal vessels impossible due to a very large span of flow velocities. We demonstrate that three-dimensional Doppler OCT combined with three-dimensional four Fourier transform fast phase unwrapping (3D 4FT FPU) allows for the calculation of the volumetric blood flow rate in real-time by the implementation of the algorithms in a graphics processing unit (GPU). The additive character of the flow at the furcations is proven using a microfluidic device with controlled flow rates as well as in the retinal veins bifurcations imaged in the optic disc area of five healthy volunteers. We show values of blood flow rates calculated for retinal capillaries and vessels with diameters in the range of 12-150 µm. The potential of quantitative measurement of retinal blood flow volume includes noninvasive detection of carotid artery stenosis or occlusion, measuring vascular reactivity and evaluation of vessel wall stiffness
52-week results of the phase 3 randomized study comparing SB4 with reference etanercept in patients with active rheumatoid arthritis
Objective: To compare the 52-week efficacy and safety of SB4 [an etanercept biosimilar] with reference etanercept (ETN) in patients with active RA. Methods: In a phase 3, randomized, double-blind, multicentre study, patients with moderate to severe RA despite MTX treatment were randomized to receive 50 mg/week of s.c. SB4 or ETN up to week 52. Efficacy assessments included ACR response rates, 28-joint DAS, Simplified and Clinical Disease Activity Indices and changes in the modified total Sharp score (mTSS). Safety and immunogenicity were also evaluated. Results: A total of 596 patients were randomized to receive either SB4 (n = 299) or ETN (n = 297) and 505 (84.7%) patients completed 52 weeks of the study. At week 52, the ACR20 response rates in the per-protocol set were comparable between SB4 (80.8%) and ETN (81.5%). All efficacy results were comparable between the two groups and they were maintained up to week 52. Radiographic progression was also comparable and the change from baseline in the mTSS was 0.45 for SB4 and 0.74 for ETN. The safety profile of SB4 was similar to that of ETN and the incidence of anti-drug antibody development up to week 52 was 1.0 and 13.2% in the SB4 and ETN groups, respectively. Conclusion: Efficacy including radiographic progression was comparable between SB4 and ETN up to week 52. SB4 was well tolerated and had a similar safety profile to that of ETN. Trial registration number: ClinicalTrials.gov NCT01895309, EudraCT 2012-005026-30
A phase III randomised, double-blind, parallel-group study comparing SB4 with etanercept reference product in patients with active rheumatoid arthritis despite methotrexate therapy
To compare the efficacy and safety of SB4 (an etanercept biosimilar) with reference product etanercept (ETN) in patients with moderate to severe rheumatoid arthritis (RA) despite methotrexate (MTX) therapy. METHODS:This is a phase III, randomised, double-blind, parallel-group, multicentre study with a 24-week primary endpoint. Patients with moderate to severe RA despite MTX treatment were randomised to receive weekly dose of 50 mg of subcutaneous SB4 or ETN. The primary endpoint was the American College of Rheumatology 20% (ACR20) response at week 24. Other efficacy endpoints as well as safety, immunogenicity and pharmacokinetic parameters were also measured. RESULTS: 596 patients were randomised to either SB4 (N=299) or ETN (N=297). The ACR20 response rate at week 24 in the per-protocol set was 78.1% for SB4 and 80.3% for ETN. The 95% CI of the adjusted treatment difference was -9.41% to 4.98%, which is completely contained within the predefined equivalence margin of -15% to 15%, indicating therapeutic equivalence between SB4 and ETN. Other efficacy endpoints and pharmacokinetic endpoints were comparable. The incidence of treatment-emergent adverse events was comparable (55.2% vs 58.2%), and the incidence of antidrug antibody development up to week 24 was lower in SB4 compared with ETN (0.7% vs 13.1%). CONCLUSIONS:SB4 was shown to be equivalent with ETN in terms of efficacy at week 24. SB4 was well tolerated with a lower immunogenicity profile. The safety profile of SB4 was comparable with that of ETN
A phase III randomised, double-blind, parallel-group study comparing SB4 with etanercept reference product in patients with active rheumatoid arthritis despite methotrexate therapy
Objectives: To compare the efficacy and safety of SB4 (an etanercept biosimilar) with reference product etanercept (ETN) in patients with moderate to severe rheumatoid arthritis (RA) despite methotrexate (MTX) therapy. Methods: This is a phase III, randomised, double-blind, parallel-group, multicentre study with a 24-week primary endpoint. Patients with moderate to severe RA despite MTX treatment were randomised to receive weekly dose of 50 mg of subcutaneous SB4 or ETN. The primary endpoint was the American College of Rheumatology 20% (ACR20) response at week 24. Other efficacy endpoints as well as safety, immunogenicity and pharmacokinetic parameters were also measured. Results: 596 patients were randomised to either SB4 (N=299) or ETN (N=297). The ACR20 response rate at week 24 in the per-protocol set was 78.1% for SB4 and 80.3% for ETN. The 95% CI of the adjusted treatment difference was -9.41% to 4.98%, which is completely contained within the predefined equivalence margin of -15% to 15%, indicating therapeutic equivalence between SB4 and ETN. Other efficacy endpoints and pharmacokinetic endpoints were comparable. The incidence of treatment-emergent adverse events was comparable (55.2% vs 58.2%), and the incidence of antidrug antibody development up to week 24 was lower in SB4 compared with ETN (0.7% vs 13.1%). Conclusions: SB4 was shown to be equivalent with ETN in terms of efficacy at week 24. SB4 was well tolerated with a lower immunogenicity profile. The safety profile of SB4 was comparable with that of ETN
Massively parallel data processing for quantitative total flow imaging with optical coherence microscopy and tomography.
We present an application of massively parallel processing of quantitative flow measurements data acquired using spectral optical coherence microscopy (SOCM). The need for massive signal processing of these particular datasets has been a major hurdle for many applications based on SOCM. In view of this difficulty, we implemented and adapted quantitative total flow estimation algorithms on graphics processing units (GPU) and achieved a 150 fold reduction in processing time when compared to a former CPU implementation. As SOCM constitutes the microscopy counterpart to spectral optical coherence tomography (SOCT), the developed processing procedure can be applied to both imaging modalities. We present the developed DLL library integrated in MATLAB (with an example) and have included the source code for adaptations and future improvements
Optical coherence tomography OCT - a novel tool for art conservation and cataloguing
Przedstawione zostaną przykłady obrazowania stratygrafii obrazów olejnych, w tym również w zastosowaniu do oceny autentyczności inskrypcji lub sygnatur. Poza tym omówione zostanie wykorzystanie OCT jako narzędzia wspomagającego stratygrafię LIBS, jak również do oceny zakresu korozji hydrologicznej szkła witrażowego oraz do monitorowania reakcji obiektu (obrazu) na zmianę warunków klimatycznych w jego otoczeniu.An application of OCT - a noninvasive diagnostic tool for examination of objects of art is discussed on the examples taken from research conducted at Nicolaus Copernicus University in Toruń, Poland. The following subjects have been discussed: stratigraphy of oil paintings on canvas, its specific application to analysis of order and authenticity of inscriptions on paintings, 'absolute' LIBS stratigraphy - OCT aided, application of OCT for examination of corrosion of stained glass, and monitoring of environmental induced deformations of canvas supports
Stratigraphic analysis of historical wooden samples from ancient bowed string instruments by laser induced breakdown spectroscopy
One of the most hotly debated subjects in lutherie circles is the composition of the finishing layers applied by the violinmakers of the past on their valuable bowed string instruments. These are often composed of several organic and inorganic materials, variously mixed and overlaid. During the last decade many analytical strategies were put in place in order to correctly identify these materials. The most used are surely non- and micro-invasive spectroscopic techniques (e.g. XRF, EDX, FTIR) integrated, when possible, with the imaging and tomographic ones with a multi-analytical approach. In this work, Laser-Induced Breakdown Spectroscopy (LIBS) and Optical Coherence Tomography (OCT) were tested together on laboratory mockups and historical bowed string instruments in order to identify and characterize the materials composing the finishing layers of these selected artworks