109 research outputs found

    Ankle MRI for Anterolateral Soft Tissue Impingement: Increased Accuracy with the Use of Contrast-Enhanced Fat-Suppressed 3D-FSPGR MRI

    Get PDF
    OBJECTIVE: To validate the use of contrast-enhanced (CE) fat-suppressed three-dimensional (3D) fast gradient-recalled acquisition in the steady state with radiofrequency spoiling (FSPGR) magnetic resonance imaging (MRI) for the diagnosis of anterolateral soft tissue impingement of the ankle, as compared to the use of routine ankle MRI. MATERIALS AND METHODS: Contrast-enhanced fat-suppressed 3D-FSPGR MRI and routine MRI scans were retrospectively reviewed for 45 patients with arthroscopically proven anterolateral impingement. In addition, scans were reviewed in 45 control subjects with diagnoses other than impingement. Two radiologists independently reviewed the two sets of images in random order. Using areas (Az) under the receiver operating characteristic curve (ROC), we compared the depiction of anterolateral soft tissue impingement in the two sets of images. RESULTS: The overall accuracy for lesion characterization was significantly higher (p < 0.05) using the CE fat-suppressed 3D-FSPGR MR images (Az = 0.892 and 0.881 for reader 1 and 2, respectively) than using the routine MR images (Az = 0.763 and 0.745). The use of CE fat-suppressed 3D-FSPGR MRI enhanced impingement depiction in most cases. However, in cases with a thickened non-enhancing scar or joint effusion, the routine images better depicted a soft tissue mass that intruded into anterolateral gutter than the CE images. CONCLUSION: The use of CE fat-suppressed 3D-FSPGR MRI of the ankle allows a more accurate assessment of anterolateral soft tissue impingement of the ankle, as compared to the use of routine MRIope

    Nanomechanical In Situ Monitoring of Proteolysis of Peptide by Cathepsin B

    Get PDF
    Characterization and control of proteolysis of peptides by specific cellular protease is a priori requisite for effective drug discovery. Here, we report the nanomechanical, in situ monitoring of proteolysis of peptide chain attributed to protease (Cathepsin B) by using a resonant nanomechanical microcantilever immersed in a liquid. Specifically, the detection is based on measurement of resonant frequency shift arising from proteolysis of peptides (leading to decrease of cantilever's overall mass, and consequently, increases in the resonance). It is shown that resonant microcantilever enables the quantification of proteolysis efficacy with respect to protease concentration. Remarkably, the nanomechanical, in situ monitoring of proteolysis allows us to gain insight into the kinetics of proteolysis of peptides, which is well depicted by Langmuir kinetic model. This implies that nanomechanical biosensor enables the characterization of specific cellular protease such as its kinetics

    Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts

    Get PDF
    PURPOSE: The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer. MATERIALS AND METHODS: For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence. RESULTS: The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38). CONCLUSIONS: Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil

    Morton Neuroma: Evaluated with Ultrasonography and MR Imaging

    Get PDF
    Objective The purpose of this study was to compare the diagnostic accuracy of both ultrasonography (US) and magnetic resonance imaging (MRI) for the assessment of Morton neuroma. Materials and Methods Our study group was comprised of 20 neuromas from 17 patients, and the neuromas were confirmed on surgery following evaluation with US, MRI, or both US and MRI. The diagnostic criterion for Morton neuroma, as examined by US, was the presence of a round or ovoid, well-defined, hypoechoic mass. The diagnostic criterion, based on MR imaging, was a well defined mass with intermediate to low signal intensity on both the T1- and T2-weighted images. The retrospective comparison between the sonographic and MR images was done by two experienced radiologists working in consensus with the surgical and pathologic correlations. Results The detection rate of Morton neuroma was 79% for 14 neuromas from 11 patients who had undergone US followed by an operation. The detection rate was 76% for 17 neuromas from 15 patients who had undergone MRI and a subsequent operation. The mean size of the examined neuromas was 4.9 mm on the US images and it was 5.1 mm on the MRI studies. Ten neuromas (71%) were 5 mm or less as measured by US, and three neuromas were not detected, whereas on the MRI analysis, 10 neuromas (59%) were 5 mm or less and four neuromas were not visualized. Among the patients examined during postoperative follow-up, symptoms were completely relieved in 85% and the symptoms were partially relieved in 15%. Conclusion US and MR imaging are comparable modalities with high detection rate for the evaluation of Morton neuroma.ope

    Large Superficial Basal Cell Carcinoma Arising in the Scalp

    Get PDF
    Superficial basal cell carcinoma (sBCC), a rare sub-type of basal cell carcinoma, can frequently occur in younger patients. This cancer type preferentially develops on the trunk. However, other subtypes of BCC can occur in the head and neck, probably secondary to sunlight exposure. Especially, sBCC on the scalp has been rarely-reported, accounting for 0.7~0.8% of all sBCC cases. We report a case of 71-year-old female with a large sBCC of the scalp, an unusual site of sBCC