7 research outputs found

    Relative effects of distortion and noise on target acquisition: The advisability of image restoration

    No full text
    Any image acquired by optical, electro-optical, or electronic means is likely to be degraded by the environment. The resolution of the acquired image depends on the total modulation transfer function (MTF) of the system and the additive noise. Image restoration techniques can improve image resolution significantly; however, as the noise increases, improvements via image processing become more limited because image restoration increases the noise level in the image. We characterize the influence of the MTF and noise level on human target acquisition probability to ascertain the advantages, if any, of image restoration. Conditions when restoration would be advisable are determined. © 1998 Society of Photo-Optical Instrumentation Engineers

    Video Image Preprocessing Based on Training Sequence and Optimized Control Scheme

    No full text

    Ex situ scanning electrochemical microscopy (SECM) investigation of bismuth/lead alloy film-modified gold electrodes in alkaline medium

    No full text
    Scanning electrochemical microscopy (SECM) in feedback mode was employed to characterise the reactivity and microscopic peculiarities of bismuth and bismuth/lead alloys plated onto gold disk substrates in 0.1 molL(-1) NaOH solutions. Methyl viologen was used as redox mediator, while a platinum microelectrode was employed as the SECM tip. The metal films were electrodeposited ex situ from NaOH solutions containing either bismuth ions only or both bismuth and lead ions. Approach curves and SECM images indicated that the metal films were conductive and locally reactive with oxygen to provide Bi(3+) and Pb(2+) ions. The occurrence of the latter chemical reactions was verified by local anodic stripping voltammetry (ASV) at the substrate solution interface by using a mercury-coated platinum SECM tip. The latter types of measurements allowed also verifying that lead was not uniformly distributed onto the bismuth film electrode substrate. These findings were confirmed by scanning electron microscopy images. The surface heterogeneity produced during the metal deposition process, however, did not affect the analytical performance of the bismuth coated gold electrode in anodic stripping voltammetry for the determination of lead in alkaline media, even in aerated aqueous solutions. Under the latter conditions, stripping peak currents proportional to lead concentration with a satisfactory reproducibility (within 5% RSD) were obtained
    corecore