192 research outputs found

    Pilot evaluation of the psychometric properties of a self-medication Risk Assessment Tool among elderly patients in a community setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although community pharmacists in the United Kingdom are expected to assess elderly patients' needs for additional support in managing their medicines, there is limited data on potentially useful assessment tools. We sought to evaluate a 13-item assessment instrument among community dwelling elderly patients, 65 years and above. The instrument is composed of a cognitive risk sub-scale of 6 items and a physical risk sub-scale of 7 items.</p> <p>Findings</p> <p>The instrument was administered to elderly patients in a survey performed in a community to the west of Glasgow, Scotland. The survey recruited 37 participants, 31 from 4 community pharmacies and 6 patients whose medication management tasks were managed by the West Glasgow Community Health and Care Partnership (managed patients). Community pharmacists independently rated 29 of the 37 participants' comprehension of, and dexterity in handling their medicines. We assessed scale reliability, convergent validity and criterion validity. In sub-analyses, we assessed differences in scores between the managed patients and those recruited from the community pharmacies, and between multi-compartment compliance aid users and non-users. The instrument showed satisfactory internal consistency (Cronbach's alpha of 0.792 for 13-item scale). There was significant strong negative correlation between the cognitive risk sub-scores and community pharmacists' assessment of comprehension (ρ = -0.546, p = 0.0038); and physical risk sub-scores and community pharmacists' assessment of dexterity (ρ = -0.491, p = 0.0093). The Area Under the Receiver Operator Characteristic Curve (AUC ± SE; 95%CI) showed that the instrument had good discriminatory capacity (0.86 ± 0.07; 0.68, 0.96). The best cut-off (sensitivity, specificity) was ≥4 (65%, 100%). In the sub-analyses, managed patients had significantly higher cognitive risk sub-scores (6.5 versus 4.0, p = 0.0461) compared to non-managed patients. There was a significant difference in total risk score (4 versus 2, p = 0.0135) and cognitive risk sub-score (4 versus 1.5, p = 0.0029) between users and non-users of multi-compartment compliance aids.</p> <p>Conclusions</p> <p>This instrument shows potential for use in identifying elderly patients who may have problems managing their own medicines in the community setting. However, more robust validity and reliability assessments are needed prior to introduction of the tool into routine practice.</p

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    The Influence of Personality Traits on Reported Adherence to Medication in Individuals with Chronic Disease: An Epidemiological Study in West Sweden

    Get PDF
    BACKGROUND: Limited research exists exploring the influence of personality on adherence behaviour. Since non-adherence is a major obstacle in treating prevalent chronic diseases the aim was to determine whether personality traits are related to reported adherence to medication in individuals with chronic disease. METHODOLOGY/PRINCIPAL FINDINGS: Individuals with chronic disease (n = 749) were identified in a random population sample of 5000 inhabitants aged 30-70 in two municipalities in West Sweden. Data on five personality traits, Neuroticism, Extraversion, Openness to experiences, Agreeableness, and Conscientiousness, and medication adherence behaviour was collected by questionnaires. Statistical analyses resulted in a negative relationship between Neuroticism and medication adherence (P < 0.001), while both Agreeableness (P < 0.001) and Conscientiousness (P < 0.001) were positively related to adherence. At high levels of Conscientiousness, low adherence was related to higher scores in Neuroticism. At high levels of Agreeableness, low adherence was related to low scores in Conscientiousness and high scores in Openness to experiences. CONCLUSIONS: This study demonstrated that multiple personality traits are of significant importance for adherence behaviour in individuals with chronic disease. The findings suggest that several personality traits may interact in influencing adherence behaviour. Personality traits could putatively be used to focus efforts to educate and support patients with high risk of low medical adherence

    Cellular and molecular basis for endometriosis-associated infertility

    Full text link

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore