39 research outputs found

    Prognostic value of microvascular resistance and its association to fractional flow reserve:a DEFINE-FLOW substudy

    Get PDF
    OBJECTIVE: This study aimed to evaluate the prognostic value of hyperemic microvascular resistance (HMR) and its relationship with hyperemic stenosis resistance (HSR) index and fractional flow reserve (FFR) in stable coronary artery disease. METHODS: This is a substudy of the DEFINE-FLOW cohort (NCT02328820), which evaluated the prognosis of lesions (n=456) after combined FFR and coronary flow reserve (CFR) assessment in a prospective, non-blinded, non-randomised, multicentre study in 12 centres in Europe and Japan. Participants (n=430) were evaluated by wire-based measurement of coronary pressure, flow and vascular resistance (ComboWire XT, Phillips Volcano, San Diego, California, USA). RESULTS: Mean FFR and CFR were 0.82±0.10 and 2.2±0.6, respectively. When divided according to FFR and CFR thresholds (above and below 0.80 and 2.0, respectively), HMR was highest in lesions with FFR>0.80 and CFR<2.0 (n=99) compared with lesions with FFR≀0.80 and CFR≄2.0 (n=68) (2.92±1.2 vs 1.91±0.64 mm Hg/cm/s, p<0.001). The FFR value was proportional to the ratio between HMR and the HMR+HSR (total resistance), 95% limits of agreement (−0.032; 0.019), bias (−0.003±0.02) and correlation (r(2)=0.98, p<0.0001). Cox regression model using HMR as continuous parameter for target vessel failure showed an HR of 1.51, 95% CI (0.9 to 2.4), p=0.10. CONCLUSIONS: Increased HMR was not associated with a higher rate of adverse clinical events, in this population of mainly stable patients. FFR can be equally well expressed as HMR/HMR+HSR, thereby providing an alternative conceptual formulation linking epicardial severity with microvascular resistance. TRIAL REGISTRATION NUMBER: NCT02328820

    Citescore of publications indexed in Scopus: an implementation of panel data

    Get PDF
    This article is intended to establish the variables that explain the behavior of the CiteScore metrics from 2014 to 2016, for journals indexed in Scopus in 2017. With this purpose, journals with a CiteScore value greater than 11 were selected in any of the periods, that is to say, 133 journals. For the data analysis, a model of standard corrected errors for panel was used, from which a coefficient of determination of 77% was obtained. From the results, it was possible to state that journals of arts and humanities; business; administration and accounting; economics, econometrics, and finance; immunology and microbiology; medicine and social sciences, have the greatest impact.CorporaciĂłn Universitaria Minuto de Dios, FundaciĂłn Universitaria Konrad Lorenz, Universidad de La Habana, Universidad de la Costa

    Compact solid-state CMOS single-photon detector array for in vivo NIR fluorescence lifetime oncology measurements

    Get PDF
    In near infrared fluorescence-guided surgical oncology, it is challenging to distinguish healthy from cancerous tissue. One promising research avenue consists in the analysis of the exogenous fluorophores’ lifetime, which are however in the (sub-)nanosecond range. We have integrated a single-photon pixel array, based on standard CMOS SPADs (single-photon avalanche diodes), in a compact, time-gated measurement system, named FluoCam. In vivo measurements were carried out with indocyanine green (ICG)-modified derivatives targeting the avb3 integrin, initially on a genetically engineered mouse model of melanoma injected with ICG conjugated with tetrameric cyclic pentapeptide (ICG&#x100000;E[c(RGDfK)4]), then on mice carrying tumour xenografts of U87-MG (a human primary glioblastoma cell line) injected with monomeric ICG&#x100000;c(RGDfK). Measurements on tumor, muscle and tail locations allowed us to demonstrate the feasibility of in vivo lifetime measurements with the FluoCam, to determine the characteristic lifetimes (around 500 ps) and subtle lifetime differences between bound and unbound ICG-modified fluorophores (10% level), as well as to estimate the available photon fluxes under realistic conditions

    COVID-19 publications: Database coverage, citations, readers, tweets, news, Facebook walls, Reddit posts

    Get PDF
    © 2020 The Authors. Published by MIT Press. This is an open access article available under a Creative Commons licence. The published version can be accessed at the following link on the publisher’s website: https://doi.org/10.1162/qss_a_00066The COVID-19 pandemic requires a fast response from researchers to help address biological, medical and public health issues to minimize its impact. In this rapidly evolving context, scholars, professionals and the public may need to quickly identify important new studies. In response, this paper assesses the coverage of scholarly databases and impact indicators during 21 March to 18 April 2020. The rapidly increasing volume of research, is particularly accessible through Dimensions, and less through Scopus, the Web of Science, and PubMed. Google Scholar’s results included many false matches. A few COVID-19 papers from the 21,395 in Dimensions were already highly cited, with substantial news and social media attention. For this topic, in contrast to previous studies, there seems to be a high degree of convergence between articles shared in the social web and citation counts, at least in the short term. In particular, articles that are extensively tweeted on the day first indexed are likely to be highly read and relatively highly cited three weeks later. Researchers needing wide scope literature searches (rather than health focused PubMed or medRxiv searches) should start with Dimensions (or Google Scholar) and can use tweet and Mendeley reader counts as indicators of likely importance

    Evaluation of the HadGEM3-A simulations in view of detection and attribution of human influence on extreme events in Europe

    Get PDF
    A detailed analysis is carried out to assess the HadGEM3-A global atmospheric model skill in simulating extreme temperatures, precipitation and storm surges in Europe in the view of their attribution to human influence. The analysis is performed based on an ensemble of 15 atmospheric simulations forced with observed Sea Surface Temperature of the 54 year period 1960-2013. These simulations, together with dual simulations without human influence in the forcing, are intended to be used in weather and climate event attribution. The analysis investigates the main processes leading to extreme events, including atmospheric circulation patterns, their links with temperature extremes, land-atmosphere and troposphere-stratosphere interactions. It also compares observed and simulated variability, trends and generalized extreme value theory parameters for temperature and precipitation. One of the most striking findings is the ability of the model to capture North Atlantic atmospheric weather regimes as obtained from a cluster analysis of sea level pressure fields. The model also reproduces the main observed weather patterns responsible for temperature and precipitation extreme events. However, biases are found in many physical processes. Slightly excessive drying may be the cause of an overestimated summer interannual variability and too intense heat waves, especially in central/northern Europe. However, this does not seem to hinder proper simulation of summer temperature trends. Cold extremes appear well simulated, as well as the underlying blocking frequency and stratosphere-troposphere interactions. Extreme precipitation amounts are overestimated and too variable. The atmospheric conditions leading to storm surges were also examined in the Baltics region. There, simulated weather conditions appear not to be leading to strong enough storm surges, but winds were found in very good agreement with reanalyses. The performance in reproducing atmospheric weather patterns indicates that biases mainly originate from local and regional physical processes. This makes local bias adjustment meaningful for climate change attribution

    Distal Evaluation of Functional performance with Intravascular sensors to assess the Narrowing Effect—combined pressure and Doppler FLOW velocity measurements (DEFINE-FLOW) trial: Rationale and trial design

    No full text
    Background: It remains uncertain if invasive coronary physiology beyond fractional flow reserve (FFR) can refine lesion selection for revascularization or provide additional prognostic value. Coronary flow reserve (CFR) equals the ratio of hyperemic to baseline flow velocity and has a wealth of invasive and noninvasive data supporting its validity. Because of fundamental physiologic relationships, binary classification of FFR and CFR disagrees in approximately 30%-40% of cases. Optimal management of these discordant cases requires further study. Aim: The aim of the study was to determine the prognostic value of combined FFR and CFR measurements to predict the 24-month rate of major adverse cardiac events. Secondary end points include repeatability of FFR and CFR, angina burden, and the percentage of successful FFR/CFR measurements which will not be excluded by the core laboratory. Methods: This prospective, nonblinded, nonrandomized, and multicenter study enrolled 455 subjects from 12 sites in Europe and Japan. Patients underwent physiologic lesion assessment using the 0.014” Philips Volcano ComboWire XT that provides simultaneous pressure and Doppler velocity sensors. Intermediate coronary lesions received only medical treatment unless both FFR (≀0.8) and CFR ( 0.80 and CFR ≄ 2.0. Enrollment has been completed, and final follow-up will occur in November 2019

    Characterization of quantitative flow ratio and fractional flow reserve discordance using doppler flow and clinical follow-up

    No full text
    Abstract: The physiological mechanisms of quantitative flow ratio and fractional flow reserve disagreement are not fully understood. We aimed to characterize the coronary flow and resistance profile of intermediate stenosed epicardial coronary arteries with concordant and discordant FFR and QFR. Post-hoc analysis of the DEFINE-FLOW study. Anatomical and Doppler-derived physiological parameters were compared for lesions with FFR+QFR− (n = 18) vs. FFR+QFR+ (n = 43) and for FFR−QFR+ (n = 34) vs. FFR−QFR− (n = 139). The association of QFR results with the two-year rate of target vessel failure was assessed in the proportion of vessels (n = 195) that did not undergo revascularization. Coronary flow reserve was higher [2.3 (IQR: 2.1–2.7) vs. 1.9 (IQR: 1.5–2.4)], hyperemic microvascular resistance lower [1.72 (IQR: 1.48–2.31) vs. 2.26 (IQR: 1.79–2.87)] and anatomical lesion severity less severe [% diameter stenosis 45.5 (IQR: 41.5–52.5) vs. 58.5 (IQR: 53.1–64.0)] for FFR+QFR− lesions compared with FFR+QFR+ lesions. In comparison of FFR−QFR+ vs. FFR-QFR- lesions, lesion severity was more severe [% diameter stenosis 55.2 (IQR: 51.7–61.3) vs. 43.4 (IQR: 35.0–50.6)] while coronary flow reserve [2.2 (IQR: 1.9–2.9) vs. 2.2 (IQR: 1.9–2.6)] and hyperemic microvascular resistance [2.34 (IQR: 1.85–2.81) vs. 2.57 (IQR: 2.01–3.22)] did not differ. The agreement and diagnostic performance of FFR using hyperemic stenosis resistance (> 0.80) as reference standard was higher compared with QFR and coronary flow reserve. Disagreement between FFR and QFR is partly explained by physiological and anatomical factors. Clinical Trials Registrationhttps://www.clinicaltrials.gov; Unique identifier: NCT01813435. Graphical abstract: Changes in central physiological and anatomical parameters according to FFR and QFR match/mismatch quadrants.[Figure not available: see fulltext.

    Fluorescence lifetime imaging to differentiate bound from unbound ICG-cRGD both in vitro and in vivo

    No full text
    Excision of the whole tumor is crucial, but remains difficult for many tumor types. Fluorescence lifetime imaging could be helpful intraoperative to differentiate normal from tumor tissue. In this study we investigated the difference in fluorescence lifetime imaging of indocyanine green coupled to cyclic RGD free in solution/serum or bound to integrins e.g. in tumors. The U87-MG glioblastoma cell line, expressing high integrin levels, was cultured to use in vitro and to induce 4 subcutaneous tumors in a-thymic mice (n=4). Lifetimes of bound and unbound probe were measured with an experimental time-domain single-photon avalanche diode array (time resolution <100ps). In vivo measurements were taken 30-60 minutes after intravenous injection, and after 24 hours. The in vitro lifetime of the fluorophores was similar at different concentrations (20, 50 and 100 mu M) and showed a statistically significant higher lifetime (p<0.001) of bound probe compared to unbound probe. In vivo, lifetimes of the fluorophores in tumors were significantly higher (p<0.001) than at the control site (tail) at 30-60 minutes after probe injection. Lifetimes after 24 hours confirmed tumor-specific binding (also validated by fluorescence intensity images). Based on the difference in lifetime imaging, it can be concluded that it is feasible to separate between bound and unbound probes in vivo
    corecore