248 research outputs found

    Xray Tomographic Microscopic Studies a Resin Embedded Paint Sample from a Mechanical Failing Area in the Floor Tiles of The Art of Painting by Johannes Vermeer (1632-1675)

    Get PDF
    Extended abstract of a paper presented at Microscopy and Microanalysis 2010 in Portland, Oregon, USA, August 1 - August 5, 201

    Connectivity of Phases and Growth Mechanisms in Peritectic Alloys Solidified at Low Speed: an X-Ray Tomography Study of Cu-Sn

    Get PDF
    The variety of microstructures that form at low solidification speed in peritectic alloys, bands, and islands, or even coupled (or cooperative) growth of the primary α and peritectic β phases, have been previously explained by nucleation-growth mechanisms. In a recent investigation on Cu-Sn, a new growth mechanism was conjectured on the basis of two-dimensional (2-D) optical microscopy and electron backscattered diffraction (EBSD) observations made in longitudinal sections. In the present contribution, synchrotron-based tomographic microscopy has been used to confirm this mechanism: α and β phases totally interconnected in three dimensions and bands (or islands) can result from an overlay mechanism, rather than from a nucleation events sequence. When the lateral growth of a new layer is too fast, an instability can lead to the formation of a lamellar structure as for eutectic alloy

    Regridding reconstruction algorithm for real-time tomographic imaging

    Get PDF
    Sub-second temporal-resolution tomographic microscopy is becoming a reality at third-generation synchrotron sources. Efficient data handling and post-processing is, however, difficult when the data rates are close to 10 GB s-1. This bottleneck still hinders exploitation of the full potential inherent in the ultrafast acquisition speed. In this paper the fast reconstruction algorithm gridrec, highly optimized for conventional CPU technology, is presented. It is shown that gridrec is a valuable alternative to standard filtered back-projection routines, despite being based on the Fourier transform method. In fact, the regridding procedure used for resampling the Fourier space from polar to Cartesian coordinates couples excellent performance with negligible accuracy degradation. The stronger dependence of the observed signal-to-noise ratio for gridrec reconstructions on the number of angular views makes the presented algorithm even superior to filtered back-projection when the tomographic problem is well sampled. Gridrec not only guarantees high-quality results but it provides up to 20-fold performance increase, making real-time monitoring of the sub-second acquisition process a reality

    A tilted grating interferometer for full vector field differential x-ray phase contrast tomography

    Full text link
    We report on a setup for differential x-ray phase-contrast imaging and tomography, that measures the full 2D phase-gradient information. The setup uses a simple one-dimensional x-ray grating interferometer, in which the grating structures of the interferometer are oriented at a tilt angle with respect to the sample rotation axis. In such a configuration, the differential phase images from opposing tomography projections can be combined to yield both components of the gradient vector. We show how the refractive index distribution as well as its x, y, and z gradient components can be reconstructed directly from the recorded projection data. The method can equally well be applied at conventional x-ray tube sources, to analyzer based x-ray imaging or neutron imaging. It is demonstrated with measurements of an x-ray phantom and a rat brain using synchrotron radiation

    A new type of temperature driven reorientation transition in magnetic thin films

    Full text link
    We present a new type of temperature driven spin reorientation transition (SRT) in thin films. It can occur when the lattice and the shape anisotropy favor different easy directions of the magnetization. Due to different temperature dependencies of the two contributions the effective anisotropy may change its sign and thus the direction of the magnetization as a function of temperature may change. Contrary to the well-known reorientation transition caused by competing surface and bulk anisotropy contributions the reorientation that we discuss is also found in film systems with a uniform lattice anisotropy. The results of our theoretical model study may have experimental relevance for film systems with positive lattice anisotropy, as e.g. thin iron films grown on copper.Comment: 7 pages, 4 figures, accepted for publication in EPJ

    Technical note: A collision prediction tool using Blender.

    Get PDF
    Non-coplanar radiotherapy treatment techniques on C-arm linear accelerators have the potential to reduce dose to organs-at-risk in comparison with coplanar treatment techniques. Accurately predicting possible collisions between gantry, table and patient during treatment planning is needed to ensure patient safety. We offer a freely available collision prediction tool using Blender, a free and open-source 3D computer graphics software toolset. A geometric model of a C-arm linear accelerator including a library of patient models is created inside Blender. Based on the model, collision predictions can be used both to calculate collision-free zones and to check treatment plans for collisions. The tool is validated for two setups, once with and once without a full body phantom with the same table position. For this, each gantry-table angle combination with a 2° resolution is manually checked for collision interlocks at a TrueBeam system and compared to simulated collision predictions. For the collision check of a treatment plan, the tool outputs the minimal distance between the gantry, table and patient model and a video of the movement of the gantry and table, which is demonstrated for one use case. A graphical user interface allows user-friendly input of the table and patient specification for the collision prediction tool. The validation resulted in a true positive rate of 100%, which is the rate between the number of correctly predicted collision gantry-table combinations and the number of all measured collision gantry-table combinations, and a true negative rate of 89%, which is the ratio between the number of correctly predicted collision-free combinations and the number of all measured collision-free combinations. A collision prediction tool is successfully created and able to produce maps of collision-free zones and to test treatment plans for collisions including visualisation of the gantry and table movement

    A hybrid column generation and simulated annealing algorithm for direct aperture optimization.

    Get PDF
    The purpose of this work was to develop a hybrid column generation (CG) and simulated annealing (SA) algorithm for direct aperture optimization (H-DAO) and to show its effectiveness in generating high quality treatment plans for intensity modulated radiation therapy (IMRT) and mixed photon-electron beam radiotherapy (MBRT). The H-DAO overcomes limitations of the CG-DAO with two features improving aperture selection (branch-feature) and enabling aperture shape changes during optimization (SA feature). The H-DAO algorithm iteratively adds apertures to the plan. At each iteration, a branch is created for each field provided. First, each branch determines the most promising aperture of its assigned field and adds it to a copy of the current apertures. Afterwards, the apertures of each branch undergo an MU-weight optimization followed by an SA-based simultaneous shape and MU-weight optimization and a second MU-weight optimization. The next H-DAO iteration continues the branch with the lowest objective function value. IMRT and MBRT treatment plans for an academic, a brain and a head and neck case generated using the CG DAO and H DAO were compared. For every investigated case and both IMRT and MBRT, the H-DAO leads to a faster convergence of the objective function value with number of apertures compared to the CG-DAO. In particular, the H DAO needs on average half the apertures to reach the same objective function value as the CG DAO for a specifically selected number of apertures. The average aperture areas are 27% smaller for H-DAO than for CG-DAO leading to a slightly larger discrepancy between optimized and final dose. However, a dosimetric benefit remains. The H-DAO was successfully developed and applied to IMRT and MBRT. The faster convergence with number of apertures of the H-DAO compared to the CG-DAO allows to select a better compromise between plan quality and number of apertures

    Impact of the gradient in gantry-table rotation on dynamic trajectory radiotherapy plan quality.

    Get PDF
    BACKGROUND To improve organ at risk (OAR) sparing, dynamic trajectory radiotherapy (DTRT) extends VMAT by dynamic table and collimator rotation during beam-on. However, comprehensive investigations regarding the impact of the gantry-table (GT) rotation gradient on the DTRT plan quality have not been conducted. PURPOSE To investigate the impact of a user-defined GT rotation gradient on plan quality of DTRT plans in terms of dosimetric plan quality, dosimetric robustness, deliverability, and delivery time. METHODS The dynamic trajectories of DTRT are described by GT and gantry-collimator paths. The GT path is determined by minimizing the overlap of OARs with planning target volume (PTV). This approach is extended to consider a GT rotation gradient by means of a maximum gradient of the path ( ) between two adjacent control points ( ) and maximum absolute change of G ( ). Four DTRT plans are created with different maximum G&∆G: &  = 0.5&0.125 (DTRT-1), 1&0.125 (DTRT-2), 3&0.125 (DTRT-3) and 3&1‍(DTRT-4), including 3-4 dynamic trajectories, for three clinically motivated cases in the head and neck and brain region (A, B, and C). A reference VMAT plan for each case is created. For all plans, plan quality is assessed and compared. Dosimetric plan quality is evaluated by target coverage, conformity, and OAR sparing. Dosimetric robustness is evaluated against systematic and random patient-setup uncertainties between in the lateral, longitudinal, and vertical directions, and machine uncertainties between in the dynamically rotating machine components (gantry, table, collimator rotation). Delivery time is recorded. Deliverability and delivery accuracy on a TrueBeam are assessed by logfile analysis for all plans and additionally verified by film measurements for one case. All dose calculations are Monte Carlo based. RESULTS The extension of the DTRT planning process with user-defined to investigate the impact of the GT rotation gradient on plan quality is successfully demonstrated. With increasing , slight (case C, : up to‍-1‍Gy) and substantial (case A, : up to -9.3 Gy, case‍B, : up to -4.7‍Gy) improvements in OAR sparing are observed compared to VMAT, while maintaining similar target coverage. All plans are delivered on the TrueBeam. Expected and actual machine position values recorded in the logfiles deviated by 96% (2%‍global/2 mm Gamma passing rate) with the dose calculation. With increasing , delivery time is prolonged by <2 min/trajectory (DTRT-4) compared to VMAT and DTRT-1. The DTRT plans for case A and B and the VMAT plan for case C plan reveal the best dosimetric robustness for the considered uncertainties. CONCLUSION The impact of the GT rotation gradient on DTRT plan quality is comprehensively investigated for three cases in the head and neck and brain region. Increasing freedom in this gradient improves dosimetric plan quality at the cost of increased delivery time for the investigated cases. No clear dependency of GT rotation gradient on dosimetric robustness is observed

    Tomographic reconstruction of the small-angle x-ray scattering tensor with filtered back projection

    Get PDF
    Small-angle x-ray scattering tensor tomography provides three-dimensional information on the unre-solved material anisotropic microarchitecture, which can be hundreds of times smaller than an image pixel. We develop a direct filtered back-projection method based on algebraic filters that enables rapid tensor-tomographic reconstructions and is a few orders of magnitude faster compared to established techniques, given the same computational resources. We demonstrate the accuracy of the method on exper-imental data for a fiber-reinforced material sample. The achieved acceleration may pave the way toward the investigation of multiple large samples as well as rapid control and feedback during in situ tensor-tomographic experiments, opening perspectives for the understanding of the fundamental link between functional material properties and microarchitecture.Algorithms and the Foundations of Software technolog
    corecore