2,522 research outputs found

    Near-bottom seismic profiling: High lateral variability, anomalous amplitudes, and estimates of attenuation

    Get PDF
    For almost a decade the Marine Physical Laboratory of Scripps Institution of Oceanography has been conducting near‐bottom geophysical surveys involving quantitative seismic profiling. Operating initially at 4 kHz and more recently at 6 kHz, this system has provided a wealth of fine scale quantitative data on the acoustic properties of ocean sediments. Over lateral distances of a few meters, 7‐dB changes in overall reflected energy as well as 10‐dB changes from individual reflectors have been observed. Anomalously high amplitudes from deep reflectors have been commonly observed, suggesting that multilayer interference is prevalent in records from such pulsed cw profilers. This conclusion is supported by results from sediment core physical property work and related convolution modeling, as well as by the significant differences observed between 4‐ and 6‐kHz profiles. In general, however, lateral consistency has been adequate in most areas surveyed to permit good estimates of acoustic attenuation from returns from dipping reflectors and sediment wedges

    Ring-Expansion Metathesis Polymerization: Catalyst-Dependent Polymerization Profiles

    Get PDF
    Ring-expansion metathesis polymerization (REMP) mediated by recently developed cyclic Ru catalysts has been studied in detail with a focus on the polymer products obtained under varied reaction conditions and catalyst architectures. Depending upon the nature of the catalyst structure, two distinct molecular weight evolutions were observed. Polymerization conducted with catalysts bearing six-carbon tethers displayed rapid polymer molecular weight growth which reached a maximum value at ca. 70% monomer conversion, resembling a chain-growth polymerization mechanism. In contrast, five-carbon-tethered catalysts led to molecular weight growth that resembled a step-growth mechanism with a steep increase occurring only after 95% monomer conversion. The underlying reason for these mechanistic differences appeared to be ready release of five-carbon-tethered catalysts from growing polymer rings, which competed significantly with propagation. Owing to reversible chain transfer and the lack of end groups in REMP, the final molecular weights of cyclic polymers was controlled by thermodynamic equilibria. Large ring sizes in the range of 60−120 kDa were observed at equilibrium for polycyclooctene and polycyclododecatriene, which were found to be independent of catalyst structure and initial monomer/catalyst ratio. While six-carbon-tethered catalysts were slowly incorporated into the formed cyclic polymer, the incorporation of five-carbon-tethered catalysts was minimal, as revealed by ICP-MS. Further polymer analysis was conducted using melt-state magic-angle spinning ^(13)C NMR spectroscopy of both linear and cyclic polymers, which revealed little or no chain ends for the latter topology

    Social support on international assignments: the relevance of socio-emotional support from locals

    Get PDF
    WOS:000322696600010 (NÂș de Acesso Web of Science)Social support takes on a special significance in the context of sojourners. Using the matching/specificity hypothesis we hypothesized that sojourners’ satisfaction is increased if there is an optimal match between type and source of social support. The Index of Sojourner Social Support (ISSS; Ong &Ward, 2005) Scale was used to examine this hypothesis in the context of instrumental and socioemotional support for sojourners on work assignments. The results showed that (a) both types of social support are positively related to satisfaction with the sojourn, (b) socioemotional support is more important in predicting satisfaction with a sojourn than instrumental support, and (c) support from locals is the most important source of social support. Furthermore, we found partial support for the matching/specificity hypothesis: Only the amount of support from locals was a significant moderator and only the relationship between socioemotional support and satisfaction with a sojourn was moderated. We discuss the relevance of source and type of support for cultural adjustment and the importance of contact with locals during international sojourns.info:eu-repo/semantics/acceptedVersio

    Time and dose dependency of bone-sarcomas in patients injected with radium-224

    Get PDF
    The time course and dose dependency of the incidence of bone-sarcomas among 900 German patients treated with high doses of radium-224 is analysed in terms of a proportional hazards model with a log-normal dependency of time to tumor and a linear-quadratic dose relation. The deduced dose dependency agrees well with a previous analysis in terms of a non-parametric proportional hazards model, and confirms the temporal distribution which has been used in the Radioepidemiological Tables of NIH. However, the linear-quadratic dose-response model gives a risk estimate for low doses which is somewhat less than half that obtained under the assumption of linearity. Dedicated to Prof. W. Jacobi on the occasion of his 60th birthday Work performed under Euratom contracts BI6-D-083-D, BI6-F-111-D, U.S. Department of Energy contract DE-AC 02-76 EV-00119, the U.S. National Cancer Institut

    SeisCORK meeting report

    Get PDF
    SeisCORK meeting, November 15 and 16, 2004, Stress/Mohr Engineering, Houston, Texas 77041-1205The purpose of this meeting was to explore design options to simultaneously acquire borehole seismic data and hydro-geological data (pressure, temperature, fluid sampling and microbiological sampling) on a single CORK system. The scientific focus was to add a seismic component to the Juan de Fuca Hydrogeology program. By permanently installing a sensor string in the borehole our goal was to enable: l) time-lapse VSP's and offset VSP's with sufficient data quality to study amplitude versus offset, shear wave anisotropy, and lateral heterogeneity; 2) monitoring of micro- and nano- earthquake activity around the site for correlation with pressure transients. Because of the difficulty in ensuring adequate coupling through multiple casing strings we concluded that it was impractical to install the vertical seismic array with 10m spacing (50-60 nodes) that would be necessary for VSP's and time-lapse VSP's. We did describe a scenario for a vertical seismic array with approximately 100m spacing (5-6 nodes) that could be used for offset-VSP's and seismic monitoring. This uses some unique technology and involves two seismic strings: one in the annulus between the 4- 1/2" and 10-3/4" casings and one in the middle of the 4-1/2" casing.Funding was provided by the National Science Foundation under Grant No. OCE-0450318
    • 

    corecore