7,132 research outputs found
Classroom Discussions as Distortions: Examining Discriminatory Teacher Practices
Ms. Mendez, English Department chair in a large urban high school, has noticed a persistent pattern in the practices of her colleagues. These practices tend to be racially insensitive and emphasize a noncritical view that does not attend to students’ experiences and positions students from a deficit perspective. Realizing that such practices serve as social reproductions of racist and classist orientations that reproduce the existing social order, Ms. Mendez decided school leadership should be informed. However, she worries that the school’s leadership will not work to enact change and instead will take her concerns lightly
Singular lagrangian systems and variational constrained mechanics on Lie algebroids
The purpose of this paper is describe Lagrangian Mechanics for constrained
systems on Lie algebroids, a natural framework which covers a wide range of
situations (systems on Lie groups, quotients by the action of a Lie group,
standard tangent bundles...). In particular, we are interested in two cases:
singular Lagrangian systems and vakonomic mechanics (variational constrained
mechanics). Several examples illustrate the interest of these developments.Comment: 42 pages, Section with examples improve
Performance Characterization of a Solenoid-type Gas Valve for the Magnetron Source at FNAL
The magnetron-style ion sources currently in operation at Fermilab
use piezoelectric gas valves to function. This kind of gas valve is sensitive
to small changes in ambient temperature, which affect the stability and
performance of the ion source. This motivates the need to find an alternative
way of feeding H2 gas into the source. A solenoid-type gas valve has been
characterized in a dedicated off-line test stand to assess the feasibility of
its use in the operational ion sources. ion beams have been extracted
at 35 keV using this valve. In this study, the performance of the solenoid gas
valve has been characterized measuring the beam current output of the magnetron
source with respect to the voltage and pulse width of the signal applied to the
gas valve.Comment: 4 pp. arXiv admin note: text overlap with arXiv:1701.0175
Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source
As the main ion source for the accelerator complex, magnetron ion
sources have been used at Fermilab since the 1970s. At the offline test stand,
new R&D is carried out to develop and upgrade the present magnetron-type
sources of ions of up to 80 mA and 35 keV beam energy in the context of
the Proton Improvement Plan. The aim of this plan is to provide high-power
proton beams for the experiments at FNAL. In order to reduce the amount of
tuning and monitoring of these ion sources, a new electronic system consisting
of a current-regulated arc discharge modulator allow the ion source to run at a
constant arc current for improved beam output and operation. A solenoid-type
gas valve feeds gas into the source precisely and independently of
ambient temperature. This summary will cover several studies and design changes
that have been tested and will eventually be implemented on the operational
magnetron sources at Fermilab. Innovative results for this type of ion source
include cathode geometries, solenoid gas valves, current controlled arc pulser,
cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor
reduction, with the aim to improve source lifetime, stability, and reducing the
amount of tuning needed. In this summary, I will highlight the advances made in
ion sources at Fermilab and will outline the directions of the continuing R&D
effort.Comment: 4 pp. arXiv admin note: substantial text overlap with
arXiv:1701.0175
Improvements on the Stability and Operation of a Magnetron H- Ion Source
The magnetron H- ion sources developed in the 1970s currently in operation at
Fermilab provide beam to the rest of the accelerator complex. A series of
modifications to these sources have been tested in a dedicated offline test
stand with the aim of improving different operational issues. The solenoid type
gas valve was tested as an alternative to the piezoelectric gas valve in order
to avoid its temperature dependence. A new cesium oven was designed and tested
in order to avoid glass pieces that were present with the previous oven,
improve thermal insulation and fine tune its temperature. A current-regulated
arc modulator was developed to run the ion source at a constant arc current,
providing very stable beam outputs during operations. In order to reduce beam
noise, the addition of small amounts of N2 gas was explored, as well as testing
different cathode shapes with increasing plasma volume. This paper summarizes
the studies and modifications done in the source over the last three years with
the aim of improving its stability, reliability and overall performance.Comment: 8 pages, 19 figure
- …