107 research outputs found

    A randomized double-blind trial of an interventional device treatment of functional mitral regurgitation in patients with symptomatic congestive heart failure-Trial design of the REDUCE FMR study

    Get PDF
    The Carillon Mitral Contour System has been studied in 3 nonrandomized trials in patients with symptomatic congestive heart failure and functional mitral regurgitation. The REDUCE FMR study is a uniquely designed, double-blind trial evaluating the impact of the Carillon device on reducing regurgitant volume, as well as assessing the safety and clinical efficacy of this device. Carillon is a coronary sinus-based indirect annuloplasty device. Eligible patients undergo an invasive venogram to assess coronary sinus vein suitability for the Carillon device. If the venous dimensions are suitable, they are randomized on a 3:1 basis to receive a device or not. Patients and assessors are blinded to the treatment assignment. The primary end point is the difference in regurgitant volume at 1 year between the implanted and nonimplanted groups. Other comparisons include clinical parameters such as heart failure hospitalizations, 6-minute walk test, Kansas City Cardiomyopathy Questionnaire (KCCQ), and other echocardiographic parameters. An exercise echo substudy will also be included

    The REDUCE FMR Trial: A Randomized Sham-Controlled Study of Percutaneous Mitral Annuloplasty in Functional Mitral Regurgitation

    Get PDF
    Objectives This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling. Background Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis. Methods In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham. The pre-specified primary endpoint was change in mitral regurgitant volume at 12 months, measured by quantitative echocardiography according to an intention-to-treat analysis. Results Patients (69.8 ± 9.5 years of age) were randomized to either the treatment (n = 87) or the sham-controlled (n = 33) arm. There were no significant differences in baseline characteristics between the groups. In the treatment group, 73 of 87 (84%) had the device implanted. The primary endpoint was met, with a statistically significant reduction in mitral regurgitant volume in the treatment group compared to the control group (decrease of 7.1 ml/beat [95% confidence interval [CI]: −11.7 to −2.5] vs. an increase of 3.3 ml/beat [95% CI: −6.0 to 12.6], respectively; p = 0.049). Additionally, there was a significant reduction in left ventricular volumes in patients receiving the device versus those in the control group (left ventricular end-diastolic volume decrease of 10.4 ml [95% CI: −18.5 to −2.4] vs. an increase of 6.5 ml [95% CI: −5.1 to 18.2]; p = 0.03 and left ventricular end-systolic volume decrease of 6.2 ml [95% CI: −12.8 to 0.4] vs. an increase of 6.1 ml [95% CI: −1.42 to 13.6]; p = 0.04). Conclusions The Carillon device significantly reduced mitral regurgitant volume and left ventricular volumes in symptomatic patients with functional mitral regurgitation receiving optimal medical therapy. (Carillon Mitral Contour System for Reducing Functional Mitral Regurgitation [REDUCE FMR]; NCT02325830

    The Estimation of GC Repeats in Promoter P1 of IGF-1 Gene and Their Influence on IGF-1 Plasma Levels in Stable Angina Patients

    Get PDF
    Increased plasma levels of insulin-like growth factor 1 (IGF-1) are observed in advanced arteriosclerosis, but the reasons for these elevated levels remain unknown. One possibility to explain them is variation in the sequences that control IGF-1 gene expression. The goal of this study was to determine the effect of molecular variants of the IGF-1 P1 promoter on IGF-1 serum levels and to determine the impact of IGF-1 levels on the severity of coronary atherosclerosis. Methods: Blood samples were collected from 101 consecutive patients undergoing routine angiography. Genomic DNA was isolated from the nucleated cells of the blood plasma as described (2). Based on the presence of conformational differences in the DNA strand and on the absence of single nucleotide polymorphisms, the DNA from 38 patients was further analyzed by the “allelic ladder” method to determine the number of repeated GC dinucleotides in the P1 promoter of the IGF-1 gene. In addition, we analyzed serum growth hormone levels in order to examine the effect on systemic IGF-1 synthesis. Results: Conformational differences in the P1 promoter of the IGF-1 gene were observed in 38 out of the 101 patients. Several genotypes, depending on the number of GC repeats, were observed (11/19,17/19,18/19,18/21,19/19,19/20,19/21). Interestingly, a family history of coronary artery disease was seen less often among individuals heterozygous for the GC repeats. A lower IGF-1 levels were seen in non-variant carriers (homozygous genotypes for 19 or 21 repeats of GC, or heterozygous genotype 19/21) when compared to the variant group (other heterozygous genotypes then 19/21) (181.6 ± 47.9 ng/mL vs. 227.7 ± 73.7, p = 0.026). A correlation between IGF-1, IGF-binding protein number 3, and growth hormone levels (p = ns) was not observed, and there were no significant differences in the growth hormone levels in the studied group of patients (p = ns)

    Protocol for collection and separation of bone marrow mononuclear cells in Chlorocebus aethiops

    Full text link
    Abstract: Chlorocebus aethiops is a species of non-human primate frequently used in biomedical research. Some research involves this species as an experimental model for various diseases and possible treatment with stem cells. The bone marrow is one of the main sources of these cells and provides easy access. The aim of this study was to standardize the protocol of collection and separation of bone marrow in C. aethiops. Ten animals were submitted to puncture of bone marrow with access to the iliac crest and cell separation by density gradient. The bone marrow of C. aethiops had an average of 97% viability. From the results achieved, we can conclude that C. aethiops is an excellent model to obtain and isolate mononuclear cells from bone marrow, fostering several studies in the field of cell therapy

    Therapeutic decision-making for patients with fluctuating mitral regurgitation

    Get PDF
    Mitral regurgitation (MR) is a common, progressive, and difficult-to-manage disease. MR is dynamic in nature, with physiological fluctuations occurring in response to various stimuli such as exercise and ischaemia, which can precipitate the development of symptoms and subsequent cardiac events. In both chronic primary and secondary MR, the dynamic behaviour of MR can be reliably examined during stress echocardiography. Dynamic fluctuation of MR can also have prognostic value; patients with a marked increase in regurgitant volume or who exhibit increased systolic pulmonary artery pressure during exercise have lower symptom-free survival than those who do not experience significant changes in MR and systolic pulmonary artery pressure during exercise. Identifying patients who have dynamic MR, and understanding the mechanisms underlying the condition, can potentially influence revascularization strategies (such as the surgical restoration of coronary blood flow) and interventional treatment (including cardiac resynchronization therapy and new approaches targeted to the mitral valve)

    Role of computed tomography imaging for transcatheter valvular repair/insertion

    Get PDF
    During the last decade, the development of transcatheter based therapies has provided feasible therapeutic options for patients with symptomatic severe valvular heart disease who are deemed inoperable. The promising results of many nonrandomized series and recent landmark trials have increased the number of percutaneous transcatheter valve procedures in high operative risk patients. Pre-procedural imaging of the anatomy of the aortic or mitral valve and their spatial relationships is crucial to select the most appropriate device or prosthesis and to plan the percutaneous procedure. Multidetector row computed tomography provides 3-dimensional volumetric data sets allowing unlimited plane reconstructions and plays an important role in pre-procedural screening and procedural planning. This review will describe the evolving role of multidetector row computed tomography in patient selection and strategy planning of transcatheter aortic and mitral valve procedures

    European Perspectives

    No full text
    corecore