154 research outputs found

    Supersymmetry for integrable hierarchies on loop superalgebras

    Full text link
    The algebraic approach is employed to formulate N=2 supersymmetry transformations in the context of integrable systems based on loop superalgebras sl^(p+1,p),p1\hat{\rm sl}(p+1,p), p \ge 1 with homogeneous gradation. We work with extended integrable hierarchies, which contain supersymmetric AKNS and Lund-Regge sectors. We derive the one-soliton solution for p=1p=1 which solves positive and negative evolution equations of the N=2 supersymmetric model.Comment: Latex, 21 page

    Ventricular Tachycardia Detection Using Bipolar Electrogram Analysis is Site Specific

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75656/1/j.1540-8159.1992.tb03039.x.pd

    Psychosocial impact of implantable cardioverter defibrillators (ICD) in young adults with Tetralogy of Fallot

    Get PDF
    Item does not contain fulltextOBJECTIVE: To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). METHODS: Included were 26 ToF-patients with an ICD (age 44 +/- 12 years), and two control groups consisting of 28 ToF-patients without an ICD (age 40 +/- 10 years) and a group of 35 ICD-patients of older age without ToF (age 72.0 +/- 8 years). This last control group was chosen to represent the "older general ICD population" with acquired heart disease seen at the out-patient clinic. Psychosocial functioning encompassed daily functioning, subjective health status, quality of life, anxiety, depression, coping and social support. RESULTS: ToF-patients with ICD showed diminished psychosocial functioning in comparison to ToF-patients without ICD. This was reflected by diminished subjectively perceived physical functioning (p = 0.01), general health perception (p < 0.01) and a lower satisfaction with life (p = 0.02). In comparison to older ICD-patients, ToF-patients with ICD showed less satisfaction with life (p = 0.03), experienced more anxiety (p = 0.01) and showed less favourable coping styles, although physical functioning was better for ToF-patients with ICD than for older ICD-patients (p = 0.01). More inappropriate shocks were found in ToF-patients with ICD compared to the older ICD-patients. CONCLUSION: In patients with ToF, ICD implantation had a major impact on psychosocial functioning which should be taken into account when considering ICD implantation in these young patients. To help improve psychosocial functioning, psychological counselling attuned to the specific needs of these patients may be useful.1 juli 201

    ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices—Summary Article A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines) 11This document was approved by the American College of Cardiology Foundation Board of Trustees in September 2002, the American Heart Association Science Advisory and Coordinating Committee in August 2002, and the North American Society for Pacing and Electrophysiology in August 2002.22The ACC/AHA Task Force on Practice Guidelines makes every effort to avoid any actual or potential conflicts of interest that might arise as a result of an outside relationship or personal interest of a member of the writing panel. Specifically, all members of the writing panel are asked to provide disclosure statements of all such relationships that might be perceived as real or potential conflicts of interest. These statements are reviewed by the parent task force, reported orally to all members of the writing panel at the first meeting, and updated as changes occur. The conflict of interest information for the writing committee members is posted on the ACC, AHA, and NASPE Web sites with the full-length version of the update.33When citing this document, the ACC, the AHA, and NASPE would appreciate the following citation format: Gregoratos G, Abrams J, Epstein AE, Freedman RA, Hayes DL, Hlatky MA, Kerber RE, Naccarelli GV, Schoenfeld MH, Silka MJ, Winters SL. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices—Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). J Am Coll Cardiol2002;40:1703–19.44Copies: This document is available on the World Wide Web sites of the ACC (www.acc.org) and the AHA (www.americanheart.org). A single copy of the complete guidelines is available by calling 800-253-4636 (US only) or writing the American College of Cardiology, Resource Center, 9111 Old Georgetown Road, Bethesda, MD 20814-1699 (ask for No. 71-0237). To obtain a copy of the Summary Article, ask for reprint No. 71-0236. To purchase additional reprints (specify version and reprint number): up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 410-528-4426, fax 410-528-4264, or e-mail [email protected](J Am Coll Cardiol 2002;40:1703–19.)66©2002 by the American College of Cardiology Foundation and the American Heart Association, Inc.

    Get PDF

    ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to update the 1998 pacemaker guidelines)

    Get PDF
    The current update of the ACC/AHA/NASPE Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices includes several significant changes in the recommendations and in the supporting narrative portion. In this summary, we list the updated recommendations along with the respective 1998 recommendations, each one accompanied by a brief comment outlining the rationale for the changes, additions, or deletions. All new or revised recommendations are listed in the second column and appear in boldface type. References that support either the 1998 recommendations that have not changed or the new or revised recommendations are noted in parentheses at the end of each recommendation. The reader is referred to the full-text version of the guidelines posted on the American College of Cardiology (ACC), American Heart Association (AHA), and North American Society for Pacing and Electrophysiology (NASPE) World Wide Web sites for a more detailed exposition of the rationale for these changes. In addition to the recommendation changes listed here, this update includes an expanded section on the selection of pacemakers and implantable cardioverter-defibrillators (ICDs) that reflects the technical advances that have taken place since 1998. A brief expanded summary of pacemaker follow-up procedures is also new to these guidelines. For both of these expanded sections, the reader is referred to the online full-text version

    Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support

    Get PDF
    Surgical management of tetralogy of Fallot (TOF) results in anatomic and functional abnormalities in the majority of patients. Although right ventricular volume load due to severe pulmonary regurgitation can be tolerated for many years, there is now evidence that the compensatory mechanisms of the right ventricular myocardium ultimately fail and that if the volume load is not eliminated or reduced by pulmonary valve replacement the dysfunction might be irreversible. Cardiovascular magnetic resonance (CMR) has evolved during the last 2 decades as the reference standard imaging modality to assess the anatomic and functional sequelae in patients with repaired TOF. This article reviews the pathophysiology of chronic right ventricular volume load after TOF repair and the risks and benefits of pulmonary valve replacement. The CMR techniques used to comprehensively evaluate the patient with repaired TOF are reviewed and the role of CMR in supporting clinical decisions regarding pulmonary valve replacement is discussed

    ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines

    Get PDF
    Several excellent guidelines already exist on treating patients who have ventricular arrhythmias (Table 1). The purpose of this document is to update and combine the previously published recommendations into one source approved by the major cardiology organizations in the United States and Europe. We have consciously attempted to create a streamlined document, not a textbook, that would be useful specifically to locate recommendations on the evaluation and treatment of patients who have or may be at risk for ventricular arrhythmias. Thus, sections on epidemiology, mechanisms and substrates, and clinical presentations are brief, because there are no recommendations for those sections. For the other sections, the wording has been kept to a minimum, and clinical presentations have been confined to those aspects relevant to forming recommendations
    corecore