17 research outputs found

    A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty

    Get PDF
    AimsThe primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.MethodsA total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses.ResultsThe mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group.ConclusionThe mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected.Orthopaedics, Trauma Surgery and Rehabilitatio

    Higher risk of 2-year cup revision of ceramic-on-ceramic versus ceramic-on-polyethylene bearing: analysis of 33,454 primary press-fit total hip arthroplasties registered in the Dutch Arthroplasty Register (LROI)

    Get PDF
    Background and purpose: The influence of bearing on short-term revision in press-fit total hip arthroplasty (THA) remains under-reported. The aim of this study was to describe 2-year cup revision rates of ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoPE). Patients and methods: Primary press-fit THAs with one of the three most used cups available with both CoC or CoPE bearing recorded in the Dutch Arthroplasty Register (LROI) were included (2007-2019). Primary outcome was 2-year cup revision for all reasons. Secondary outcomes were: reasons for revision, incidence of different revision procedures and use of both bearings over time. Results: 2-year Kaplan-Meier cup revision rate in 33,454 THAs (12,535 CoC; 20,919 CoPE) showed a higher rate in CoC (0.67% [95% CI, 0.54-0.81]) compared to CoPE (0.44% [95% CI, 0.34-0.54]) (p = 0.004). Correction for confounders (age, gender, cup type, head size) resulted in a hazard ratio (HR) of 0.64 [95%CI, 0.48-0.87] (p = 0.019). Reasons for cup revision differed only by more cup revision due to loosening in CoC (26.2% vs.1 3.2%) (p = 0.030). For aseptic loosening a revision rate of 0.153% [95% CI, 0.075-0.231] was seen in CoC and 0.058% [95%CI 0.019-0.097] in CoPE (p = 0.007). Correction for head size resulted in a HR of 0.475 [95% CI, 0.197-1.141] (p = 0.096). Incidence of different revision procedures did not differ between bearings. Over time the use of CoPE has increased and CoC decreased. Conclusions: A higher 2-year cup revision rate in press-fit THA was observed in CoC compared to CoPE. Cup loosening was the only significantly different reason for revision and seen more often in CoC and mostly aseptic. Future randomised controlled trials need to confirm causality, since the early cup revision data provided has the potential to be useful when choosing the bearing in press-fit THA, when combined with other factors like bone quality and patient and implant characteristics.Orthopaedics, Trauma Surgery and Rehabilitatio

    Stiffness of the healing medial collateral ligament of the mouse.

    No full text
    Contains fulltext : 58021.pdf (publisher's version ) (Closed access)The knee joints of mice can serve as a model for studying knee ligament properties. The goal of our study was to measure the structural stiffness of the medial collateral ligament (MCL) of the murine knee. A tensile test was developed for this purpose. First 84 femur-MCL-tibia complexes of 11-week-old C57Black6 mice were tested. Of four groups (n = 14 per group) the right MCL was ruptured. The mice were sacrificed at 1.5, 3, 6, and 9 weeks after the operation. The other two groups served as controls at 0 and 9 weeks after the operation. Absolute values of the structural stiffness of the healed MCLs at 1.5 weeks were initially significantly lower than their unoperated controls, but were not different from normal values at three, six, and nine weeks of healing. The structural stiffness of the unoperated controls increased by 11% at 20 weeks compared to 11 weeks of age

    Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature

    No full text
    Surfaces of medical implants can be enhanced with the favorable properties of titanium-nitride (TiN). In a review of English medical literature, the effects of TiN-coating on orthopaedic implant material in preclinical studies were identified and the influence of these effects on the clinical outcome of TiN-coated orthopaedic implants was explored. The TiN-coating has a positive effect on the biocompatibility and tribological properties of implant surfaces; however, there are several reports of third body wear due to delamination, increased ultrahigh molecular weight polyethylene wear, and cohesive failure of the TiN-coating. This might be due to the coating process. The TiN-coating process should be optimized and standardized for titanium alloy articulating surfaces. The clinical benefit of TiN-coating of CoCrMo knee implant surfaces should be further investigated
    corecore