6 research outputs found

    Protection levels of N95-level respirator substitutes proposed during the COVID-19 pandemic: Safety concerns and quantitative evaluation procedures

    Get PDF
    OBJECTIVE: The COVID-19 pandemic has precipitated widespread shortages of filtering facepiece respirators (FFRs) and the creation and sharing of proposed substitutes (novel designs, repurposed materials) with limited testing against regulatory standards. We aimed to categorically test the efficacy and fit of potential N95 respirator substitutes using protocols that can be replicated in university laboratories. SETTING: Academic medical centre with occupational health-supervised fit testing along with laboratory studies. PARTICIPANTS: Seven adult volunteers who passed quantitative fit testing for small-sized (n=2) and regular-sized (n=5) commercial N95 respirators. METHODS: Five open-source potential N95 respirator substitutes were evaluated and compared with commercial National Institute for Occupational Safety and Health (NIOSH)-approved N95 respirators as controls. Fit testing using the 7-minute standardised Occupational Safety and Health Administration fit test was performed. In addition, protocols that can be performed in university laboratories for materials testing (filtration efficiency, air resistance and fluid resistance) were developed to evaluate alternate filtration materials. RESULTS: Among five open-source, improvised substitutes evaluated in this study, only one (which included a commercial elastomeric mask and commercial HEPA filter) passed a standard quantitative fit test. The four alternative materials evaluated for filtration efficiency (67%-89%) failed to meet the 95% threshold at a face velocity (7.6 cm/s) equivalent to that of a NIOSH particle filtration test for the control N95 FFR. In addition, for all but one material, the small surface area of two 3D-printed substitutes resulted in air resistance that was above the maximum in the NIOSH standard. CONCLUSIONS: Testing protocols such as those described here are essential to evaluate proposed improvised respiratory protection substitutes, and our testing platform could be replicated by teams with similar cross-disciplinary research capacity. Healthcare professionals should be cautious of claims associated with improvised respirators when suggested as FFR substitutes

    Unfortunate but not noncompliant

    No full text

    Response to Protocol Review: Convened meeting for approval

    No full text

    Helicobacter-Induced Chronic Active Lymphoid Aggregates Have Characteristics of Tertiary Lymphoid Tissue

    No full text
    Susceptible strains of mice that are naturally or experimentally infected with murine intestinal helicobacter species develop hepatic inflammatory lesions that have previously been described as chronic active hepatitis. The inflammatory infiltrates in some models of chronic autoimmunity or inflammation resemble tertiary lymphoid organs hypothesized to arise by a process termed lymphoid organ neogenesis. To determine whether hepatic inflammation caused by infection with helicobacter could give rise to tertiary lymphoid organs, we used fluorescence-activated cell sorting, immunohistochemistry, and in situ hybridization techniques to identify specific components characteristic of lymphoid organs in liver tissue sections and liver cell suspensions from helicobacter-infected mice. Small venules (high endothelial venules [HEVs]) in inflammatory lesions in Helicobacter species-infected livers were positive for peripheral node addressin. Mucosal addressin cell adhesion molecule also stained HEVs and cells with a staining pattern consistent with scattered stromal cells. The chemokines SLC (CCL 21) and BLC (CXCL13) were present, as were B220-positive B cells and T cells. The latter included a naïve (CD45lo-CD62Lhi) population. These findings suggest that helicobacter-induced chronic active hepatitis arises through the process of lymphoid organ neogenesis

    Review of Rodent Euthanasia Methods

    No full text
    The optimal choice of euthanasia method for laboratory rodents depends on a number of factors, including the scientific goals of the study, the need to minimize animal pain and/or distress, applicable guidelines and laws, the training and proficiency of personnel, and the safety and emotional needs of the personnel performing the euthanasia. This manuscript aims to provide guidance to researchers so they may select the method of euthanasia that results in minimal experimental confounds, such as the creation of artifact and alteration of tissues and analytes. Specific situations addressed include euthanasia of large numbers of rodents and euthanasia of neonates. Recent literature supports the notion of significant strain-dependent differences in response to euthanasia methods such as CO2 inhalation. To assist researchers in selecting a strain-appropriate method of euthanasia, the authors present a summary of methodologies for assessing the effectiveness of euthanasia techniques, including elements and parameters for a scoring rubric to assess them
    corecore