48 research outputs found
The use of functional tests and planned coronary angiography after percutaneous coronary revascularization in clinical practice. Results from the AFTER multicenter study
Background: The follow-up strategies after percutaneous coronary intervention (PCI) have relevant clinical and economic implications. The purpose of this prospective observational multicenter study was to evaluate the effect of clinical, procedural and organizational variables on the execution of functional testing (FT) and planned coronary angiography (CA) after PCI, and to assess the impact of American College of Cardiology (ACC)/American Heart Association (AHA) guidelines on clinical practice. Methods: Four hundred twenty consecutive patients undergoing PCI were categorized as class I, IIB and III indications for follow-up FT according to ACC/AHA guidelines recommendations. Furthermore, all patients were grouped according to the presence or absence of FT and/or planned CA over 12 months after PCI. Multivariable analysis was used to assess the potential predictors of test execution. Results: During the 12-month follow-up at least one test was performed in 72% of patients with class I indication, 63% of patients with class IIB indication and 75% of patients with class III indication (p=ns). A total of 283 patients (67%) underwent testing. The use of tests was associated with younger age (R. R. 0.94, C. I. 0.91 +/- 0.97, p<0.001), a lower number of diseased vessels (R.R. 0.60, C.I. 0.43 +/- 0.84, p=0.003), follow-up by the center performing PCI (R. R. 2.64, C. I. 1.43 +/- 4.86, p=0.002), and the specific center at which PCI was performed. Most asymptomatic patients completed their testing prematurely with respect to the risk period for restenosis. Conclusions: The use of FT and planned CA after PCI is unrelated to patient's symptom status, and depends on patient's age and logistics. ACC/AHA guidelines have no influence in clinical practice, and test timing is not tailored to the risk period for restenosis. (C) 2008 Elsevier Ireland Ltd. All rights reserved
Determinants of radiation dose during right transradial access. insights from the RAD-MATRIX study
Background The RAD-MATRIX trial reported a large operator radiation exposure variability in right radial percutaneous coronary procedures. The reasons of these differences are not well understood. Our aim was to appraise the determinants of operator radiation exposure during coronary right transradial procedures. Methods Patient arrangement during transradial intervention was investigated across operators involved in the RAD-MATRIX trial. Operator radiation exposure was analyzed according to the position of the patient right arm (close or far from the body) and in relation to the size of the upper leaded glass. Results Among the 14 operators who agreed to participate, there was a greater than 10-fold difference in radiation dose at thorax level (from 21.5 to 267 μSv) that persisted after normalization by dose-area product (from 0.35 to 3.5 μSv/Gy*cm2). Among the operators who positioned the instrumented right arm far from the body (110.4 μSv, interquartile range 71.5-146.5 μSv), thorax dose was greater than that in those who placed the instrumented arm close to the right leg (46.1 μSv, 31.3-56.8 μSv, P =.02). This difference persisted after normalization by dose-area product (P =.028). The use of a smaller full glass shield was also associated with a higher radiation exposure compared with a larger composite shield (147.5 and 60 μSv, respectively, P =.016). Conclusions In the context of the biggest radiation study conducted in patients undergoing transradial catheterization, the instrumented right arm arrangement close to the leg and greater upper leaded shield dimensions were associated with a lower operator radiation exposure. Our findings emphasize the importance of implementing simple preventive measures to mitigate the extra risks of radiation exposure with right radial as compared with femoral access
Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: Rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX)
Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimet
A Qualitative Exploration of the Use of Contraband Cell Phones in Secured Facilities
Offenders accepting contraband cell phones in secured facilities violate state corrections law, and the possession of these cell phones is a form of risk taking behavior. When offenders continue this risky behavior, it affects their decision making in other domains where they are challenging authorities; and may impact the length of their incarceration. This qualitative phenomenological study examined the lived experience of ex-offenders who had contraband cell phones in secured correctional facilities in order to better understand their reasons for taking risks with contraband cell phones. The theoretical foundation for this study was Trimpop\u27s risk-homeostasis and risk-motivation theories that suggest an individual\u27s behaviors adapt to negotiate between perceived risk and desired risk in order to achieve satisfaction. The research question explored beliefs and perceptions of ex-offenders who chose to accept the risk of using contraband cell phones during their time in secured facilities. Data were collected anonymously through recorded telephone interviews with 8 male adult ex-offenders and analyzed using thematic content analysis. Findings indicated participants felt empowered by possession of cell phones in prison, and it was an acceptable risk to stay connected to family out of concern for loved ones. The study contributes to social change by providing those justice system administrators, and prison managers responsible for prison cell phone policies with more detailed information about the motivations and perspectives of offenders in respect to using contraband cell phones while imprisoned in secured facilities
In-hospital antithrombotic therapy and outcomes of elderly patients on warfarin undergoing percutaneous coronary intervention: Insights from the WAR-STENT registry
In the patients on warfarin undergoing percutaneous coronary intervention included in the prospective, multicentre, observational WAR-STENT registry, age >75 years was associated with a significant increase in in-hospital major bleeding, length of hospitalization, and use of bare-metal stents, with no differences in the peri-procedural management and antithrombotic therapy. (c) 2022 Cardiological Society of India. Published by Elsevier, a division of RELX India, Pvt. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Operator Radiation Exposure During Percutaneous Coronary Procedures Through the Left or Right Radial Approach
Background—
Transradial percutaneous coronary procedures may be effectively performed through the right radial approach (RRA) or the left radial approach (LRA), but data on radiation dose absorbed by operators comparing the two approaches are lacking. The aim of the present study was to evaluate radiation dose absorbed by operators during coronary procedures through the RRA and LRA.
Methods and Results—
Three operators were equipped with 5 different dosimeters (left wrist, shoulder, thorax outside the lead apron, thorax under the lead apron, and thyroid) during RRA or LRA for coronary procedures. Each month, the dosimeters were analyzed to determine the radiation dose absorbed. From February to December 2009, 390 patients were randomly assigned to the RRA (185 patients; age, 66±11 years) or the LRA (185 patients; age, 66±11 years). There were no significant differences in fluoroscopy time (for RRA, 369 seconds; interquartile range, 134 to 857 seconds; for LRA, 362 seconds; interquartile range, 142 to 885 seconds;
P
=0.58) between the 2 groups. There were no significant differences in monthly radiation dose at the thorax (0.85±0.46 mSv for RRA and 1.12±0.78 mSv for LRA,
P
=0.33), at the thyroid (0.36±0.2 mSv for RRA and 0.34±0.3 mSv for LRA,
P
=0.87), and at the shoulder (0.73±0.44 mSv for RRA and 0.94±0.42 mSv for LRA,
P
=0.27). The dose at the wrist was significantly higher for the RRA (2.44±1.12 mSv) compared with the LRA (1±0.8 mSv,
P
=0.002). In both radial approaches, the thoracic radiation dose under the lead apron was undetectable.
Conclusions—
Compared with RRA, LRA for coronary procedures is associated with similar radiation dose for operators at the body, shoulder, or thyroid level, with a possible significant advantage at the wrist. The cumulative radiation dose for both approaches is well under to the annual dose-equivalent limit.
Clinical Trial Registration—
URL:
http://www.clinicaltrials.gov