28 research outputs found

    Feasibility and patient’s experiences of perioperative telemonitoring in major abdominal surgery:an observational pilot study

    Get PDF
    Background: Telemonitoring during the perioperative trajectory may improve patient outcomes and self-management. The aim of this study is to assess the feasibility of and patient’s experiences with telemonitoring before and after major abdominal surgery to inform future study design. Methods: Patients planned for elective major abdominal surgery wore a sensor and answered well-being questions on a tablet daily for at least 2 weeks preoperatively up to 30-days postoperatively. Feasibility was assessed by participation and completion rate, compliance per day, weekly satisfaction scores, and reasons for nonscheduled contact. Results: Twenty-three patients were included (participation rate of 54.5%) with a completion rate of 69.6%. Median compliance with the wearable sensor and well-being questions was respectively: 94.7% and 83.3% preoperatively at home; 100% and 66.7% postoperatively in-hospital; and 95.4% and 85.8% postoperatively at home. Median weekly satisfaction scores for both wearing the sensor and well-being questions were 5 (IQR, 4–5). Contact moments were related to absence of sensor data and technological issues (76.0%) or patient discomfort and insecurity (24.0%). Conclusions: In this study, telemonitoring showed high satisfaction and compliance during the perioperative trajectory. Future trial design regarding the effectiveness of telemonitoring requires embedding in clinical practice and support for patients, relatives, and healthcare personnel

    A Statistical Shape Model of the Morphological Variation of the Infrarenal Abdominal Aortic Aneurysm Neck

    Get PDF
    Hostile aortic neck characteristics, such as short length and large diameter, have been associated with type Ia endoleaks and reintervention after endovascular aneurysm repair (EVAR). However, such characteristics partially describe the complex aortic neck morphology. A more comprehensive quantitative description of 3D neck shape might lead to new insights into the relationship between aortic neck morphology and EVAR outcomes in individual patients. This study identifies the 3D morphological shape components that describe the infrarenal aortic neck through a statistical shape model (SSM). Pre-EVAR CT scans of 97 patients were used to develop the SSM. Parameterization of the morphology was based on the center lumen line reconstruction, a triangular surface mesh of the aortic lumen, 3D coordinates of the renal arteries, and the distal end of the aortic neck. A principal component analysis of the parametrization of the aortic neck coordinates was used as input for the SSM. The SSM consisted of 96 principal components (PCs) that each described a unique shape feature. The first five PCs represented 95% of the total morphological variation in the dataset. The SSM is an objective model that provides a quantitative description of the neck morphology of an individual patient

    Geometric Analysis of the Gore Excluder Conformable Endoprosthesis in the Infrarenal Aortic Neck: One Year Results of the EXCeL Registry

    Get PDF
    Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. Results: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was &lt; 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR −2.3, 4.7; p =.042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR −0.5, 1.8; p =.019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m −1 (IQR 26, 56) and did not significantly change thereafter. Conclusion: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.</p

    Continuous monitoring of vital signs with the Everion biosensor on the surgical ward:a clinical validation study

    Get PDF
    Background: Wearable sensors enable continuous vital sign monitoring, although information about their performance on nursing wards is scarce. Vital signs measured by telemonitoring and nurse measurements on a surgical ward were compared to assess validity and reliability. Methods: In a prospective observational study, surgical patients wore a wearable sensor (Everion, Biovotion AG, Zürich, Switzerland) that continuously measured heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and temperature during their admittance on the ward. Validity was evaluated using repeated-measures correlation and reliability using Bland-Altman plots, mean difference, and 95% limits of agreement (LoA). Results: Validity analyses of 19 patients (median age, 68; interquartile range, 62.5–72.5 years) showed a moderate relationship between telemonitoring and nurse measurements for HR (r = 0.53; 95% confidence interval, 0.44–0.61) and a poor relationship for RR, SpO2, and temperature. Reliability analyses showed that Everion measured HR close to nurse measurements (mean difference, 1 bpm; LoA, −16.7 to 18.7 bpm). Everion overestimated RR at higher values, whereas SpO2 and temperature were underestimated. Conclusions: A moderate relationship was determined between Everion and nurse measurements at a surgical ward in this study. Validity and reliability of telemonitoring should also be assessed with gold standard devices in future clinical trials

    Three-Dimensional Geometric Analysis of Balloon-Expandable Covered Stents Improves Classification of Complications after Fenestrated Endovascular Aneurysm Repair

    Get PDF
    In balloon-expandable covered stent (BECS) associated complications after fenestrated endovascular aneurysm repair (FEVAR), geometric analysis may determine the cause of failure and influence reintervention strategies. This study retrospectively classifies BECS-associated complications based on computed tomographic angiography (CTA) applied geometric analysis. BECS-associated complications of FEVAR-patients treated in two large vascular centers between 2012 and 2021 were included. The post-FEVAR CTA scans of complicated Advanta V12 BECSs were analyzed geometrically and complications were classified according to its location in the BECS. BECS fractures were classified according to an existing classification system. In 279 FEVAR-patients, 34 out of the 683 included Advanta V12 BECS (5%) presented with a complication. Two Advanta V12 complications occurred during the FEVAR procedure and 32 occurred during follow-up of which five post-FEVAR CTA scans were missing or not suitable for analysis. In the remaining 27 BECSs complications were classified as (endoleaks (n = 8), stenoses (n = 4), occlusions (n = 6), fractures (n = 3), and a combination of complications (n = 6)). All BECSs associated complications after FEVAR with available follow up CTA scans could be classified. Geometric analysis of BECS failure post-FEVAR can help to plan the reintervention strategy

    Position- and posture-dependent vascular imaging—a scoping review

    Get PDF
    Objectives: Position- and posture-dependent deformation of the vascular system is a relatively unexplored field. The goal of this scoping review was to create an overview of existing vascular imaging modalities in different body positions and postures and address the subsequent changes in vascular anatomy.Methods: Scopus, Medline, and Cochrane were searched for literature published between January 1, 2000, and June 30, 2022, incorporating the following categories: image modality, anatomy, orientation, and outcomes.Results: Out of 2446 screened articles, we included 108. The majority of papers used ultrasound (US, n = 74) in different body positions and postures with diameter and cross-sectional area (CSA) as outcome measures. Magnetic resonance imaging (n = 22) and computed tomography (n = 8) were less frequently used but allowed for investigation of other geometrical measures such as vessel curvature and length. The venous system proved more sensitive to postural changes than the arterial system, which was seen as increasing diameters of veins below the level of the heart when going from supine to prone to standing positions, and vice versa.Conclusions: The influence of body positions and postures on vasculature was predominantly explored with US for vessel diameter and CSA. Posture-induced deformation and additional geometrical features that may be of interest for the (endovascular) treatment of vascular pathologies have been limitedly reported, such as length and curvature of an atherosclerotic popliteal artery during bending of the knee after stent placement. The most important clinical implications of positional changes are found in diagnosis, surgical planning, and follow-up after stent placement.Clinical relevance statement: This scoping review presents the current state and opportunities of position- and posture-dependent imaging of vascular structures using various imaging modalities that are relevant in the fields of clinical diagnosis, surgical planning, and follow-up after stent placement.Key Points:• The influence of body positions and postures on the vasculature was predominantly investigated with US for vessel diameter and cross-sectional area.• Research into geometrical deformation, such as vessel length and curvature adaptation, that may be of interest for the (endovascular) treatment of vascular pathologies is limited in different positions and postures.• The most important clinical implications of postural changes are found in diagnosis, surgical planning, and follow-up after stent placement.</p

    Continuous Monitoring of Vital Signs With Wearable Sensors During Daily Life Activities:Validation Study

    Get PDF
    BACKGROUND: Continuous telemonitoring of vital signs in a clinical or home setting may lead to improved knowledge of patients’ baseline vital signs and earlier detection of patient deterioration, and it may also facilitate the migration of care toward home. Little is known about the performance of available wearable sensors, especially during daily life activities, although accurate technology is critical for clinical decision-making. OBJECTIVE: The aim of this study is to assess the data availability, accuracy, and concurrent validity of vital sign data measured with wearable sensors in volunteers during various daily life activities in a simulated free-living environment. METHODS: Volunteers were equipped with 4 wearable sensors (Everion placed on the left and right arms, VitalPatch, and Fitbit Charge 3) and 2 reference devices (Oxycon Mobile and iButton) to obtain continuous measurements of heart rate (HR), respiratory rate (RR), oxygen saturation (SpO(2)), and temperature. Participants performed standardized activities, including resting, walking, metronome breathing, chores, stationary cycling, and recovery afterward. Data availability was measured as the percentage of missing data. Accuracy was evaluated by the median absolute percentage error (MAPE) and concurrent validity using the Bland-Altman plot with mean difference and 95% limits of agreement (LoA). RESULTS: A total of 20 volunteers (median age 64 years, range 20-74 years) were included. Data availability was high for all vital signs measured by VitalPatch and for HR and temperature measured by Everion. Data availability for HR was the lowest for Fitbit (4807/13,680, 35.14% missing data points). For SpO(2) measured by Everion, median percentages of missing data of up to 100% were noted. The overall accuracy of HR was high for all wearable sensors, except during walking. For RR, an overall MAPE of 8.6% was noted for VitalPatch and that of 18.9% for Everion, with a higher MAPE noted during physical activity (up to 27.1%) for both sensors. The accuracy of temperature was high for VitalPatch (MAPE up to 1.7%), and it decreased for Everion (MAPE from 6.3% to 9%). Bland-Altman analyses showed small mean differences of VitalPatch for HR (0.1 beats/min [bpm]), RR (−0.1 breaths/min), and temperature (0.5 °C). Everion and Fitbit underestimated HR up to 5.3 (LoA of −39.0 to 28.3) bpm and 11.4 (LoA of −53.8 to 30.9) bpm, respectively. Everion had a small mean difference with large LoA (−10.8 to 10.4 breaths/min) for RR, underestimated SpO(2) (>1%), and overestimated temperature up to 2.9 °C. CONCLUSIONS: Data availability, accuracy, and concurrent validity of the studied wearable sensors varied and differed according to activity. In this study, the accuracy of all sensors decreased with physical activity. Of the tested sensors, VitalPatch was found to be the most accurate and valid for vital signs monitoring

    Telemedicine in patients with peripheral arterial disease:is it worth the effort?

    Get PDF
    Introduction: For patients with peripheral arterial disease (PAD), the various components of telemedicine, such as telemonitoring, telecoaching, and teleconsultation, could be valuable in daily management. The objective of this review was to give an overview of the current use of telemedicine interventions in PAD. Areas covered: A literature search was performed for studies that evaluated patients with PAD of the aorto-pedal trajectory, who were monitored by telemedicine and acted upon accordingly. The primary outcome was health-related outcomes. The studies that were found focused mainly on wearable activity monitoring and telecoaching in PAD (n = 4) or wound monitoring after vascular surgery (n = 2). Main results indicate that telemedicine interventions are able to detect (post-operative) complications early, improve functional capacity and claudication onset time, and improve PAD patients’ quality of life. Expert opinion: The use of telemedicine in PAD patients is still an under-explored area. Studies investigating the use of telemedicine in PAD are very limited and show varying results. Owing to its high potential in improving physical ability, lifestyle coaching, and timely detection of deterioration, future research should focus on proper implementation of telemedicine in PAD patients, including clinical and feasibility outcomes, effect on workload of nurses, and cost-efficiency.</p
    corecore