35 research outputs found

    Steuerreformvorschläge des Mirrlees Committee und der Stiftung Marktwirtschaft

    Get PDF
    This study describes, compares, and evaluates tax reform proposals by the British "Mirrlees Committee" and the German "Stiftung Marktwirtschaft". It considers both theoretical and administrative issues

    Comparison of measurements of the outer scale of turbulence by three different techniques

    Get PDF
    We have made simultaneous and nearly simultaneous measurements of L0, the outer scale of turbulence, at the Palomar Observatory by using three techniques: angle-of-arrival covariance measurements with the Generalized Seeing Monitor (GSM), differential-image-motion measurements with the adaptive-optics system on the Hale 5-m telescope, and fringe speed measurements with the Palomar Testbed Interferometer (PTI). The three techniques give consistent results, an outer scale of approximately 10-20 m, despite the fact that the spatial scales of the three instruments vary from 1 m for the GSM to 100 m for the PTI

    Non-destructive low-temperature contacts to MoS2\textrm{MoS}_2 nanoribbon and nanotube quantum dots

    Get PDF
    Molybdenum disulfide nanoribbons and nanotubes are near-one dimensional semiconductors with strong spin-orbit interaction, a nanomaterial highly promising for quantum electronic applications. Here, we demonstrate that a bismuth semimetal layer between the contact metal and this nanomaterial strongly improves the properties of the contacts. Two-point resistances on the order of 100kΩ100\textrm{k}\Omega are observed at room temperature. At cryogenic temperature, Coulomb blockade is visible. The resulting stability diagrams indicate a marked absence of trap states at the contacts and the corresponding disorder, compared to previous devices using low-work function metals as contacts. Single level quantum transport is observed at temperatures below 100mK.Comment: 7 pages, 5 figure

    Water management in novel direct membrane deposition fuel cells under low humidification

    No full text
    Polymer electrolyte membrane fuel cells (PEMFCs) fabricated by direct membrane deposition (DMD) were shown to work even at dry conditions without significant deterioration of the membrane resistance. Here, in situ neutron radiography is used to investigate the water management in those fuel cells to uncover the phenomena that lead to the robust operation under low humidification. A constant level of humidification within the membrane electrode assembly (MEA) of a DMD fuel cell is observed even under dry anode operation and 15% relative humidity on the cathode side. This proves a pronounced back diffusion of generated water from the cathode side to the anode side through the thin deposited membrane layer. Over the entire range of polarization curves a very high similarity of the water evolution in anode and cathode flow fields is found in spite of different humidification levels. It is shown that the power density of directly deposited membranes in contrast to a 50 μm thick N-112 membrane is only marginally affected by dry operation conditions. Water profiles in through-plane direction of the MEA reveal that the water content in the DMD fuel cell remains steady even at high current densities. This is in contrast to the N-112 reference fuel cell which shows a strong increase in membrane resistance and a reduced MEA water content with raising current densities. Thus this new MEA fabrication technique has a promising perspective, since dry operation conditions are highly requested in order to reduce fuel cell system costs

    Non‐Destructive Low‐Temperature Contacts to MoS2 Nanoribbon and Nanotube Quantum Dots

    Get PDF
    Molybdenum disulfide nanoribbons and nanotubes are quasi-one dimensional semiconductors with strong spin-orbit interaction, a nanomaterial highly promising for quantum electronic applications. Here, we demonstrate that a bismuth semimetal layer between the contact metal and this nanomaterial strongly improves the properties of the contacts. Two-point resistances on the order of 100kΩ are observed at room temperature. At cryogenic temperature, Coulomb blockade is visible. The resulting stability diagrams indicate a marked absence of trap states at the contacts and the corresponding disorder, compared to previous devices which use low-work function metals as contacts. Single level quantum transport is observed at temperatures below 100 mK

    Single Bacteria Movement Tracking by Online Microscopy – A Proof of Concept Study

    No full text
    <div><p>In this technical report we demonstrate a low-cost online unit allowing movement tracking of flagellated bacteria on a single-cell level during fermentation processes. The system’s ability to distinguish different metabolic states (viability) of bacteria by movement velocity was investigated. A flow-through cuvette with automatically adjustable layer thickness was developed. The cuvette can be used with most commercially available laboratory microscopes equipped with 40× amplification and a digital camera. In addition, an automated sample preparation unit and a software module was developed measuring size, moved distance, and speed of bacteria. In a proof of principle study the movement velocities of <i>Bacillus amyloliquefaciens</i> FZB42 during three batch fermentation processes were investigated. In this process the bacteria went through different metabolic states, vegetative growth, diauxic shift, vegetative growth after diauxic shift, and sporulation. It was shown that the movement velocities during the different metabolic states significantly differ from each other. Therefore, the described setup has the potential to be used as a bacteria viability monitoring tool. In contrast to some other techniques, such as electro-optical techniques, this method can even be used in turbid production media.</p></div

    In-Situ Cartilage Functionality Assessment Based on Advanced MRI Techniques and Precise Compartmental Knee Joint Loading through Varus and Valgus Stress

    No full text
    Stress MRI brings together mechanical loading and MRI in the functional assessment of cartilage and meniscus, yet lacks basic scientific validation. This study assessed the response-to-loading patterns of cartilage and meniscus incurred by standardized compartmental varus and valgus loading of the human knee joint. Eight human cadaveric knee joints underwent imaging by morphologic (i.e., proton density-weighted fat-saturated and 3D water-selective) and quantitative (i.e., T1ρ and T2 mapping) sequences, both unloaded and loaded to 73.5 N, 147.1 N, and 220.6 N of compartmental pressurization. After manual segmentation of cartilage and meniscus, morphometric measures and T2 and T1ρ relaxation times were quantified. CT-based analysis of joint alignment and histologic and biomechanical tissue measures served as references. Under loading, we observed significant decreases in cartilage thickness (p &lt; 0.001 (repeated measures ANOVA)) and T1ρ relaxation times (p = 0.001; medial meniscus, lateral tibia; (Friedman test)), significant increases in T2 relaxation times (p ≤ 0.004; medial femur, lateral tibia; (Friedman test)), and adaptive joint motion. In conclusion, varus and valgus stress MRI induces meaningful changes in cartilage and meniscus secondary to compartmental loading that may be assessed by cartilage morphometric measures as well as T2 and T1ρ mapping as imaging surrogates of tissue functionality

    Simplified process flow diagram of the sample preparation and image acquisition.

    No full text
    <p>The sample mixed with demineralized water is pumped through the flow cell. After evacuation the image acquisition can start. Before the next sampling aeration and disposal is necessary.</p

    A serial multiparametric quantitative magnetic resonance imaging study to assess proteoglycan depletion of human articular cartilage and its effects on functionality

    No full text
    Water, collagen, and proteoglycans determine articular cartilage functionality. If altered, susceptibility to premature degeneration is increased. This study investigated the effects of enzymatic proteoglycan depletion on cartilage functionality as assessed by advanced Magnetic Resonance Imaging (MRI) techniques under standardized loading. Lateral femoral condylar cartilage-bone samples from patients undergoing knee replacement (n = 29) were serially imaged by Proton Density-weighted and T1, T1ρ, T2, and T2* mapping sequences on a clinical 3.0 T MRI scanner (Achieva, Philips). Using pressure-controlled indentation loading, samples were imaged unloaded and quasi-statically loaded to 15.1 N and 28.6 N, and both before and after exposure to low-concentrated (LT, 0.1 mg/mL, n = 10) or high-concentrated trypsin (HT, 1.0 mg/mL, n = 10). Controls were not treated (n = 9). Responses to loading were assessed for the entire sample and regionally, i.e. sub- and peri-pistonally, and zonally, i.e. upper and lower sample halves. Trypsin effects were quantified as relative changes (Δ), analysed using appropriate statistical tests, and referenced histologically. Histological proteoglycan depletion was reflected by significant sub-pistonal decreases in T1 (p = 0.003) and T2 (p = 0.008) after HT exposure. Loading-induced changes in T1ρ and T2* were not related. In conclusion, proteoglycan depletion alters cartilage functionality and may be assessed using serial T1 and T2 mapping under loading
    corecore